Skip to main content

Acceptable Handrail Diameter for Use by the Elderly

  • Conference paper
  • First Online:
Advances in Industrial Design (AHFE 2020)

Part of the book series: Advances in Intelligent Systems and Computing ((AISC,volume 1202))

Included in the following conference series:

Abstract

Psychological experiments were conducted to determine allowable range of handrail diameter for use by the elderly on stairs and in the toilets. The results were cross-examined with ergonomic standpoint. The present findings are that: 1) Simple grab of handrails yields the optimal diameter of 40 mm; 2) Simultaneous application of body weight against the handrail indicates 36 mm or slimmer as the optimal diameter. The latter result is more important as seniors need stability and reliability when using handrails. These findings are in accordance with the guidelines in Sweden, New Zealand, and England & Wales, where diameters between 30 and 50 mm are unanimously accepted. Present research results point toward a revised recommendation in Japan on handrail diameters to secure safer traverse on stairs.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Kose, S., Goto, Y., Sugimoto, Y.: Handrail requirements for use by the elderly. Part 1. Basic experiment on handrail diameter. In: Summaries of Technical Papers of Annual Meeting of AIJ 1989 -Architectural Design-, pp. 799–800 (1989). (in Japanese)

    Google Scholar 

  2. Kose, S., Sugimoto, Y., Goto, Y., Konishi, T.: Handrail requirements for use by the elderly. Part 2. Allowable diameter and necessary clearance from the wall. In: Summaries of Technical Papers of Annual Meeting of AIJ 1990 -Architectural Design-, pp. 697–698 (1990). (in Japanese)

    Google Scholar 

  3. Kose, S., Sugimoto, Y., Goto, Y.: Acceptable handrail diameter for use by the elderly. In: 22nd International Congress of Applied Psychology ’90 Kyoto Abstracts, p. 385 (1990)

    Google Scholar 

  4. Kose, S.: Evaluation of handrail diameter for toilets and stairs. In: Presentation Abstracts of Japan Ergonomics Society Kanto Chapter 1989, pp. 105–106 (1989). (in Japanese)

    Google Scholar 

  5. Hall, N.B., Bennet, E.W.: Empirical assessment of handrail diameter. J. Appl. Psychol. 40(6), 381–382 (1956)

    Article  Google Scholar 

  6. Kose, S., Sugimoto, Y., Goto, Y.: Acceptable handrail position for use by the elderly. In: Designing for Everyone - Proceedings of the Eleventh Congress of the International Ergonomics Association, pp. 1116–1118 (1991)

    Google Scholar 

  7. Statens Planverks Forfratteningssamling: SBN (Svensk Bygg Norm) 1980 Utgava 2, p. 337 (1980)

    Google Scholar 

  8. Standard Association of New Zealand: NZS4121-1985. Code of Practice for design for access and use of buildings and facilities by disabled persons, p. 16 (1985)

    Google Scholar 

  9. Kose, S.: Design Guidelines of Dwellings for the Ageing Society: Japanese Approach Toward Universal Design. CIB World Building Congress, April 2001, Wellington, New Zealand (2001)

    Google Scholar 

Download references

Acknowledgements

The experiments were conducted as part of joint research between the Building Research Institute of the Ministry of Construction, the Naka Corporation Technical Laboratory, and the Comprehensive Housing R&D Institute of the Sekisui House, Ltd. Summaries of these researches were reported at the Architectural Institute of Japan Annual meetings in 1989 [1] and 1990 [2]. The former part was also orally presented at 22nd International Congress of Applied Psychology [3] and at the annual meeting of Japan Ergonomics Society Kanto Chapter [4].

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Satoshi Kose .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 The Editor(s) (if applicable) and The Author(s), under exclusive license to Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Kose, S., Sugimoto, Y., Goto, Y. (2020). Acceptable Handrail Diameter for Use by the Elderly. In: Di Bucchianico, G., Shin, C., Shim, S., Fukuda, S., Montagna, G., Carvalho, C. (eds) Advances in Industrial Design. AHFE 2020. Advances in Intelligent Systems and Computing, vol 1202. Springer, Cham. https://doi.org/10.1007/978-3-030-51194-4_28

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-51194-4_28

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-51193-7

  • Online ISBN: 978-3-030-51194-4

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics