Skip to main content

Impact of Bolt Pattern on the Fire Performance of Protected and Unprotected Concealed Timber Connections

  • Conference paper
  • First Online:
  • 1083 Accesses

Abstract

The fire performance of concealed timber beam connections has been studied over the years, and it has been shown that such connections do not perform as well as exposed and seated connections mainly due to the reduction of the beam’s cross section to accommodate the concealed steel plate. The main objective of the study presented in this paper is to investigate the performance of fully protected and unprotected concealed glued-laminated timber (glulam) beam connections when subjected to fire. For the protected connection configuration, the steel plate and bolts were fully protected from fire using wood strips and plugs, respectively. This research also studied the effect of bolt pattern on the fire performance of concealed glulam connections. Four full-size concealed glulam beam end connections: two protected and two unprotected connections were exposed to CAN/ULC-S101 standard fire, while being loaded to 100% of the ultimate design moment capacity of the weakest connection configuration. In pattern one, two rows of bolts, each of two bolts, were symmetrically positioned near the top and bottom sides of the beam cross section. While, in bolt pattern two, the bottom bolt row was shifted upward to be located at the mid height of the beam section.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   229.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   299.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   299.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Racher P, Laplanche K, Dhima D, Bouchaïr A (2010) Thermo-mechanical analysis of the fire performance of dowelled timber connection. Eng Struct 32(4):1148–1157

    Article  Google Scholar 

  2. Audebert M, Dhima D, Taazount M, Bouchaïr A (2014) Experimental and numerical analysis of timber connections in tension perpendicular to grain in fire. Fire Saf J 63:125–137

    Article  Google Scholar 

  3. Peng L, Hadjisophocleous G, Mehaffey J, Mohammad M (2012) Fire performance of timber connections, part 1: fire resistance tests on bolted wood-steel-wood and steel-wood-steel connections. J Struct Fire Eng 3(2):107–132

    Article  Google Scholar 

  4. Zarnani P, Quenneville P (2014) Design method for coupled-splice timber moment connections. In: Proceedings of the 13th world conference on timber engineering, WCTE2014, Quebec, Canada

    Google Scholar 

  5. Xu BH, Bouchaïr A, Racher P (2015) Mechanical behaviour and modelling of dowelled steel-to-timber moment-resisting connections. J Struct Eng 141(6) (2015)

    Google Scholar 

  6. Ali S, Hadjisophocleaus G, Akotuah AO, Erochko J, Zhang X (2016) Study of the fire performance of hybrid steel-timber connections with full-scale tests and finite element modelling. In: Proceedings of the international conference on applications of structural fire engineering, Dubrovnik, 15th–16th October

    Google Scholar 

  7. CSA 086-14 (2014) Engineering design in wood. Canadian Standards Association, Ottawa, Ontario

    Google Scholar 

  8. CAN/ULC-S101-14 (2014) Standard Methods of Fire Endurance Tests of Building Construction and Materials, Fifth Edition, Canada

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Aba Owusu .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Owusu, A., Salem, O.(., Hadjisophocleous, G. (2020). Impact of Bolt Pattern on the Fire Performance of Protected and Unprotected Concealed Timber Connections. In: Makovicka Osvaldova, L., Markert, F., Zelinka, S. (eds) Wood & Fire Safety. WFS 2020. Springer, Cham. https://doi.org/10.1007/978-3-030-41235-7_45

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-41235-7_45

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-41234-0

  • Online ISBN: 978-3-030-41235-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics