6.1 Introduction

This chapter illustrates how RECAP’s approach to the management and optimisation of heterogeneous infrastructure across the cloud-to-edge spectrum can address challenges to a wide range of cloud actors and applications. Four illustrative case studies are presented:

  • Infrastructure Optimisation and Network Management for 5G Networks

  • Application Optimisation for Network Functions Virtualisation for Virtual Content Distribution Networks

  • Application and Infrastructure Optimisation for Edge/Fog computing for Smart Cities

  • Capacity Planning for a Big Data Analytics Engine

For each case, we can show that insights and models generated by RECAP can help the stakeholders to better understand their application and infrastructure behaviour. Preliminary results suggests cost savings of more than 25%, up to 20% reduction in bandwidth consumption, and a 4% performance increase.

6.2 Case Study on Infrastructure Optimisation and Network Management—5G Networks

6.2.1 Introduction

This case study envisions a system that provides communication services for a variety of industry verticals including eHealth, eCommerce, and automotive. To facilitate the communications of diverse services in different scenarios within the world of fifth generation (5G) networks, the communication system has to support various categories of communication services illustrated in Fig. 6.1.

Fig. 6.1
figure 1

Categories of communication services and example of 5G use cases

Each service is needed for a specific type of application serving a particular group of customers/clients. This introduces different sets of characteristics and requirements corresponding to each type of communication service as presented in Table 6.1.

Table 6.1 Characteristics and requirements of communication services

The emergence of 5G mobile networks and the rapid evolution of 5G applications are accelerating the need and criticality of optimised infrastructure as per this case study. Additionally, the management and operation of a 5G infrastructure and network are complex not only due to the diversity of service provisioning and consumer requirements, but also due to the involvement of many stakeholders (including infrastructure service providers, network function/service providers, and content and application service providers). Each of these stakeholders has their respective and different levels of demands and requirements. As a result, a novel solution is required to enable:

  • the adoption of various applications under different scenarios on a shared and distributed infrastructure;

  • on-demand resource provisioning considering increased network dynamics and complexity; and

  • the fulfilment of Quality of Service (QoS) and Quality of Experience (QoE) parameters set and agreed with service consumers.

6.2.2 Issues and Challenges

The communication services between user mobile devices and content services/applications are realised with a set of network functions and numerous physical radio units. In the context of virtualised networks, network functions are virtualised and chained to each other to form a network service providing network and service access to user devices through radio units. A network function virtualisation (NFV) infrastructure is required to accommodate the network function components. Within this infrastructure, virtualised components are deployed in a distributed networking region including the access network, edge network, core network, and remote data centres. Figure 6.2 illustrates a typical forwarding graph of a network service in an LTE network. The network service is composed of multiple virtual network functions (VNFs): eNodeB, Mobility Management Entity (MME), Serving Gateway (SGW), and Packet Data Network Gateway (PGW), and Home Subscriber Server (HSS).

Fig. 6.2
figure 2

A forwarding graph of a network service in an LTE network

The adoption of such a distributed architecture for the network and its services introduces four major challenges when rolling out a network service:

  1. 1.

    The communication system facilitates various types of applications/services, namely voice/video calls, audio/video streaming, web surfing, and instant messaging. This introduces a high complexity in understanding individual network services and associated dynamic workloads.

  2. 2.

    The placement and autoscaling of VNFs are needed by the communication system in order to enable dynamic resource provisioning. VNF components in control and user planes have different features and requirements. As such, to fully address the placement and autoscaling, it is necessary to understand and predict not only the variation of workload and resource utilisation but also the characteristics of the components. Diversity in requirements and implementation, together with the dispersion of components across the network infrastructure, makes placement and autoscaling of VNFs a significant challenge.

  3. 3.

    User behaviour needs to be explored for accurate workload predictions. To obtain knowledge of user behaviour, data communicated in control and user planes need to be analysed, and correlations thoroughly investigated. This analysis is challenging, as one requires domain knowledge regarding behaviour of network services and the telecommunication network more broadly.

  4. 4.

    Multi-tenancy is demanded in emerging 5G mobile networks where multiple network services are deployed and operating on top of a shared infrastructure. Different communication services come with different QoS requirements that desire a capability of adaptation and prioritising in resource allocation and management. In short, 5G brings complexity in the shape of mixed criticality and scale.

6.2.3 Implementation

6.2.3.1 Requirements

To fully address all the aforementioned challenges, it requires a complete control loop from data collection and analysis to optimisations on both infrastructure and application levels, and further up to the deployment of optimisation plans. This places an overall requirement on a system, such as RECAP, to enable a wide range of automation tasks as listed below:

  • Profiling network/service functions and infrastructural resources

  • Automated service and infrastructure deployment

  • Automated orchestration and optimisation of services and the infrastructural resource planning and provisioning

  • Observability of behaviours of the system and services at run-time

To ensure end-to-end QoS (and by inference required service availability and reliability) in a complex large-scale use case, the control loop together with automated solutions need to be capable of resource planning and provisioning in the short- and long term, e.g. in minutes or in months. The solutions are also required to satisfy constraints of multi-tenancy scenarios and multiple network services competing for shared infrastructural resources. In addition, the optimisation aspects of the solution need to manage resource provisioning that achieve utilisation and service performance goals. Moreover, the simulation aspects of the solution need to support evaluation, i.e. impact of changes in planning rules prior to any real deployments.

Table 6.2 summarises the requirements. For each requirement, a set of targeted solutions is presented to illustrate the requirements are met. A simplified mapping is presented but the solution for any single requirement could be derived from one or a combination of multiple solutions listed.

Table 6.2 Use case requirements and corresponding RECAP solutions

6.2.3.2 Implementation

To demonstrate and validate the RECAP approach, a software/hardware testbed in Tieto is used. The testbed, deployed in a lab environment, emulates a real-world telecommunication system to facilitate the development and evaluation of optimisation solutions for end-to-end communications in a 5G network and its applications. Figure 6.3 presents an overview of the testbed in which a distributed software-defined infrastructure is emulated. This is achieved with heterogeneous resources collected from multiple physical infrastructures, located in a wide range of vertical regions, to provide communication and contents services to various applications that form different network services.

Fig. 6.3
figure 3

Logical view of the testbed

From the testbed’s perspective, the entire RECAP platform is represented through the RECAP Optimiser, an external component that produces and enacts optimisation plans (through its enactor) on the testbed. Each plan presents the in-directions of VNF placement and autoscaling across the emulated network infrastructure and is executed by the testbed. Ultimately, results, in terms of both application and infrastructure performance, are collected and evaluated. These results are also fed back to the RECAP platform for further investigation and model improvement.

6.2.3.3 Deliverables and Validation

To facilitate validation, multiple validation scenarios covering all the requirements presented in Table 6.2 were defined:

  • Scenario 1: the placement and autoscaling of VNFs to fulfil QoS constraints required by a given single communication service.

  • Scenario 2: the placement and autoscaling of VNFs to fulfil QoS constraints required by multiple communication services under multi-tenant circumstances.

  • Scenario 3: the capability of RECAP simulation and optimisation tools in supporting the offline initial dimensioning the (physical) infrastructure according to traffic demands.

  • Scenario 4: the capability of RECAP simulation and optimisation tools supporting the offline planning by identifying future (physical) infrastructure needs.

  • Scenario 5: the observability and fulfilment of given QoS requirements from the VNF level put in the resources provided by the infrastructure.

The relevant models and components that form the solutions to be validated against these scenarios are summarised in Table 6.3.

Table 6.3 RECAP deliverables to address validation scenarios

The application model is developed based on the network services deployed in the Tieto testbed, and workload models are constructed using the synthetic traffic data collected from various experiments carried out within the testbed. The infrastructure network model pertains to the city of Umeå in Sweden but is influenced by BT’s national transport network and includes four network tiers (MSAN, Metro, Outer-Core, and Inner-Core). The network topology of the infrastructure is kept symmetrical, without including customisation for real-world aspects for asymmetrical node capacity, for asymmetrical node interconnection, and for asymmetrical link latencies.

6.2.4 Results

This section presents exemplar validation results for the application placement and infrastructure optimisation (Chap. 4). It addresses the problem of VNF placement across the network infrastructure. For the case study, the RECAP Simulator (Chap. 5) was used to calibrate the models used by the Infrastructure Optimiser.

In the experiments, given a network service (Fig. 6.2), the eNodeB is deployed as two separate units on different planes: the Central Unit-User plane (CU-U) and the Central Unit-Control plane (CU-C). Additionally, the SGW and PGW VNF components are located on the user plane and are termed Service Gateway-User plane (SGW-U) and Packet Data Network Gateway-User plane (PGW-U).

The optimisation solutions presented address Scenarios 3 and 4 concerned with placement and infrastructure optimisation. Five placement plans/distributions are identified as the input to the algorithm assuming (1) one forwarding graph per MSAN tier with CU-U as the user-request entry point, and (2) no currently deployed infrastructure. Table 6.4 describes these five placement distributions.

Table 6.4 Initial placement plans of VNFs

Results obtained are evaluated based on a comparison of provider and customer utility.

In Fig. 6.4, maximum provider vs. customer utility is normalised [0,1] for all distributions. Distributions 1 and 2 only use physical hardware across two tiers (as per Table 6.4) and hence exhibit the highest provider utility; this decreases by approximately 50% as the distributions start to include more than two tiers in the placement. This is understandable as more infrastructure needs to be deployed and maintained. Customer utility is highest for Distribution 5, which has three tiers MSAN, Metro, and Outer-Core (as per Table 6.4) included in the distribution. The lowest utility is when no VNFs are placed at the edge, i.e. Distribution 2, which has no MSAN; this is to be expected as the end-user request faces larger processing latency in travelling further into the network.

Fig. 6.4
figure 4

Maximum provider and customer utility of each distribution

Figure 6.4 maps the normalised provider utility and normalised customer utility of each VNF placement. The figure shows that a provider can manage its deployments by fixing the provider utility or customer utility in a way that balances business considerations.

For example, in Fig. 6.5 the provider utility is centred on 50% to ensure customer utility is centred on 75%. The intersection of threshold lines (the highlighted section in grey) identifies a set of placements that are optimal for each individual forwarding graph of the use case while satisfying defined constraints including application and infrastructure provider perspectives. The provider could choose Distribution 1, 2 or 4. However, Distribution 2 has poorer customer utility (no MSAN, higher latency) and so is disregarded. Distributions 1 and 4 utilise MSAN and Outer-Core infrastructure and have comparable customer utility. However, Distribution 1 has the higher provider utility, and thus would be the best option with caveats. It would be the best option if “consolidation” was the most important factor to the business, but not necessarily the best option if “flexibility” to service future requests was more important. In the latter case Distribution 4 is a better option because one’s current customer is satisfied (compared to Distribution 1) but the provider has significant up-swing capacity.

Fig. 6.5
figure 5

Provider utility vs. customer utility for different distributions

Figure 6.6 below illustrates simulation results for the same distributions without Distribution 2 which was disregarded due to no MSAN capacity. The graph represents all infrastructure and all remaining distributions. Utility is combined for simplicity (y-axis) and is graphed against 3 scenarios (x-axis) “normal day”, “event”, and “24% growth”. It should be more apparent that for the same scenarios and constraints as above, Distributions 1 and 4 remain the best options. Distribution 1 remains the best option and for this simulation exercise could cope with the defined event and growth scenarios. But what is a little less obvious is that its utility remained essentially static while the utility for Distribution 4 starts to trend upwards from the normal day to event to 24% growth scenario. This is primarily driven by provider utility improving as utilisation of physical assets improve; this scenario offers considerably greater capacity for future growth/event scenarios.

Fig. 6.6
figure 6

Total utility for normal day, event, and 24% growth scenarios

6.2.5 Summary

For this case study, an extensive evaluation and validation were performed for the scenarios outlined and utilising the models, components, and technologies described in Chaps. 1, 2, 3, 4, and 5. Current results contribute to more effective decision making for infrastructural resource dimensioning and planning for future 5G communication systems. The value presented is supporting informed, automated (if desirable) decisions similar to the consolidation vs. flexibility example illustrated in the Distribution 1 versus Distribution 4 options above.

6.3 Case Study in Network Functions Virtualisation: Virtual Content Distribution Networks

6.3.1 Introduction

Network Function Virtualisation (NFV ) replaces physical network appliances with software running on servers. Content Distribution Networks (CDNs) offer a service to content providers that puts content on caches closer to the content consumers or end users. Traditional Content Distribution Network (CDN) operators install customised hardware caches across the globe—sometimes within an Internet Service Provider’s network and sometimes in third-party co-located data centre facilities. Each CDN operator develops its own caching software with unique features, e.g. transcoding methods, management methods, and high availability solutions.

As of now, network operators such as BT have hardware from each of several CDN operators deployed at strategic points in its network. However, this creates several potential issues:

  • it is hard to organise sufficient physical space (in “telephone exchange” or “central office” buildings for instance) to support all the CDN operators;

  • a lot of energy is needed to power and cool all the equipment; and

  • a lot of physical effort is needed when a new CDN operator arrives or an existing one disappears.

Such factors make it attractive to consider a Virtual CDN (vCDN ) approach that aims to replace the multiple customised physical caches with standard servers and storage running multiple virtual applications per CDN operator. This lowers CDN and network operator costs and allows the content caches to be put closer to the consumer, which improves customer experience. Also, the barriers to entry for new virtual CDN operators are likely to be lower than for a physical CDN operator.

6.3.2 Overview and Business Setting

Broadband traffic on BT’s network of 50% of broadband traffic on BT’s network originates from the content caches operated by the CDN operators. At the time of writing, BT hosts CDN operators customised cache hardware in two to eleven compute sites in the UK to reduce the amount and cost of Internet peering traffic. If the caches were installed in BT’s thousand edge nodes (also known as Tier-1 MSANs (Multi-Service Access Nodes) or “Telephone Exchanges”), the cost of delivering content would be reduced by 75% and BT would reduce its network load significantly. However, the CDN operators are unlikely to want to install their hardware at up to a thousand locations in the UK; for some international CDN operators, a single compute site in London is sufficient for the entire UK.

The vCDN proposition is that BT could install the compute infrastructure at its edge sites and offer an Infrastructure-as-a-Service (IaaS) offering tailored towards CDN operators. The CDN operators would install and manage their own software on BT IaaS and thus they would maintain their unique selling points and ownership of the content provider customers. This is a potential win-win scenario: the network and CDN operators reduce operating costs and consumers get better service (Table 6.5). There are, however, several technical challenges to designing and operating a vCDN service, not least performance, orchestration, optimisation, monitoring, and remediation. These are discussed later in Sect. 6.3.3.

Table 6.5 vCDN use case requirements and corresponding RECAP components

An abstract representation of the BT UK network topology is shown in Fig. 6.7. The real locations of BT network sites are shown in Fig. 6.8; the black dots represent BT’s 5600 local exchanges, of which c. 1000 are MSANs and c. 100 BT’s Metro sites (Ofcom 2016). The 4500 local exchanges that are not MSANs are considered unsuitable for deployment of caches as they do not contain enumerates the most important vCDN use case requirements.

Fig. 6.7
figure 7

Abstract representation of BT UK network topology

Fig. 6.8
figure 8

BT network locations in UK

6.3.3 Technical Challenges

The vCDN technical challenges can be grouped into several areas as shown in Table 6.6 below.

Table 6.6 vCDN technical challenge and RECAP solution

6.3.4 Validation and Impact

The RECAP consortium is engaged with various CDN operators to develop fine-grained infrastructure and application models to develop optimisation strategies for Virtual Content Distribution Networks (vCDN). The resulting strategies will aid BT to improve the accuracy of their planning and forecasting, reducing infrastructure investment while still giving BT’s customers a superior web browsing and video streaming experience. RECAP methods will reduce the amount of human support BT’s vCDN planning process requires, enabling BT to be more agile and cost efficient (Fig. 6.9).

Fig. 6.9
figure 9

Customer utility vs. number of vCDN sites

Preliminary experimentation results are promising regarding the utility of RECAP for BT. They suggest:

  1. 1.

    The SARIMA models provide one-hour ahead workload forecasts of 11.5% accuracy with 90% confidence. This should be sufficient for CDN operators to pre-emptively adjust the sizes and number of caches running while infrastructure operators should be able to shut down or power up servers to minimise power wastage.

  2. 2.

    The RECAP DTS framework demonstrated the value of a caching hierarchy when compared to a single layer of caches at the MSAN. The results suggest a caching hierarchy can improve Provider Utility by up to 24% (see Fig. 6.10) and doubles Customer Utility at intermediate stages of infrastructure deployment, as illustrated in Fig. 6.9. Further, when compared to BT’s own optimisation strategy, it improved Provider Utility by up to 6.4% at certain intermediate stages of infrastructure deployment. The BT and RECAP optimisation both converged on deploying the maximum number of 860 nodes because the caching business case is very compelling, i.e. deploying a cache at a site always saves money and improves customer utility. For a use case where the business case is more marginal, the RECAP methodology can find a solution more significantly optimal.

  3. 3.

    The RECAP Application Optimisation (autoscaling and simulation) systems provide BT with the ability to both improve on baseline cache deployment scenarios (through comparative analysis of alternative deployment scenarios) and in run-time adapt to unforeseen and unexpected changes in workload. Simulation allows experimentation with alternative deployment strategies and evaluates the impact of changes in infrastructure, as well as application topologies and caching strategies. Validation experiments demonstrate a 4% improvement in cache efficiency when serving realistic workloads as well as the ability to efficiently adapt the amount of cache capacity deployed in heterogeneous and hierarchical networks to changes in request and network traffic patterns.

Fig. 6.10
figure 10

Provider utility vs. number of vCDN nodes

These results suggest that by implementing RECAP, BT and CDN operators can benefit from both decreased cost and increased competitiveness through:

  1. 1.

    Providing more accurate modelling, infrastructure dimensioning, and resource allocation across the chain of service provision to support better infrastructure planning.

  2. 2.

    Rapid accurate autoscaling to support fluctuations in demand and avoid under and over booking of resources.

  3. 3.

    Leveraging existing infrastructure and avoiding additional capital expenditure.

  4. 4.

    Reducing staffing requirements and freeing up valuable IT expertise.

  5. 5.

    Increased revenue through:

    1. (a)

      Delivering and maintaining high QoS.

    2. (b)

      Shortening the time for CDN operators to access infrastructure and accelerate revenue generation.

    3. (c)

      Reducing time to market for infrastructure and applications deployment.

6.4 Case Study in Edge/Fog Computing for Smart Cities

6.4.1 Introduction

This case study integrates RECAP mechanisms related to resource reallocation and optimisation in a proprietary distributed IoT platform for smart cities, called SAT-IoT. Hence, it demonstrates the capabilities to integrate RECAP components into third-party systems as well as the immediate benefits of using the RECAP approach for optimisation.

Being IoT-centric, this case study deals with hardware-software infrastructures and vertical applications as well as mobile entities and devices that move over the area of city. It is built on the assumption that smart cities provide infrastructure for handling IoT network traffic in a zone-based manner as shown in Fig. 6.11; wireless networks complement wired networks to form a hybrid network (Sauter et al. 2009); and these hybrid networks include the cloud nodes, edge nodes (IoT gateways), and further mid (fog) nodes. Mid nodes are connected to the cloud and to each other forming a mesh network. Edge nodes receive data from wireless devices located in the same geographical area. Groups of edge nodes are connected to a mid node. Edge nodes are usually not connected to each other. In this kind of scenario, it is necessary to manage the IoT network topology to adapt to moving users and changing data streams. Such a topology administration will facilitate the dynamic deployment of distributed IoT applications, the interconnection of devices in the IoT platform, and the data exchange among platform network nodes.

Fig. 6.11
figure 11

Example of IoT hybrid network for mobile devices

Consequently, this use case study requires:

  • The capability to dynamically optimise the applications’ communication topologies under an “Edge/Cloud Computing Location Transparency” model. In particular, it requires the optimal reallocation of data flows periodically at run-time to reduce bandwidth consumption and application latencies.

  • A mechanism to consider limitations of the physical topology when planning the virtual topology.

For the sake of demonstration and validation purposes, the SAT-IoT platform in RECAP is running a distributed Route Planning and City Traffic Monitoring application. Figure 6.12 illustrates this scenario based on the city of Cologne. The city area is distributed into nine geographical regions, each of which has its own edge compute node.

Fig. 6.12
figure 12

Smart city structure

6.4.2 Issues and Challenges

The formulated scenario presents some challenges with respect to the current cloud IoT/smart city systems, the edge/fog computing paradigm, and the ICT architecture optimisation. The issues and challenges addressed in this case study include:

  • Adoption of edge computing models to process the massive data generated from different IoT devices at their zone edge nodes in order to improve performance.

  • Integration of edge, fog, and cloud paradigms to develop dynamically configurable IoT systems, to achieve better optimisation results for both applications and underlying infrastructure.

  • Dynamic management of smart city environments based on distribution of mobile devices and users and their resource demands.

6.4.3 Implementation

6.4.3.1 Requirements

In order to improve the performance of the IoT system, the edge computing model seeks to process the massive data generated from different IoT devices at their zone edge nodes. Only the processing results are transmitted to the cloud infrastructure or to the IoT devices, reducing the bandwidth consumption, the response latency, and/or the storage needed (Ai et al. 2018).

Considering an IoT system that uses a hybrid network similar to Fig. 6.11, any application that processes data from zones, North and Centre, cannot naively run data processing in the zones since it requires information from both zones. A conventional cloud computing architecture is not well suited to applications where the location of devices changes, where the volume of data received in each edge node varies dynamically, or where the processing needs data from different geographical areas. Car route planners and city traffic analysers are good examples of smart city applications that make calculations with the information received from connected cars located in different zones of the city.

Thus, to process the data from, for example, the North and Centre zones, it is necessary to send it to a processing node. As these edge nodes are not connected to each other, the data from one or both zones need to pass through Mid86. Indeed, Mid86 would be the closest node to run processing for both affected zones. When considering the scenario on a larger scale with multiple zones and applications that require data from all zones to complete the processing,Footnote 1 the task of finding the most suitable processing node is non-trivial. Furthermore, where there are significant constraints on deployment capacity constraint, the underlying infrastructure becomes a factor too. Consequently, an IoT platform for smart city applications must be able to:

  • integrate of cloud, fog, and edge computing models;

  • manage the smart city data network topology at run-time;

  • use optimisation techniques that support processing aggregated data by geographical zones; and

  • monitor the IoT system and the optimisation process in run-time.

6.4.3.2 The SAT-IoT Platform

The IoT platform which forms the basis of this case study is based on the SAT-IoT platform. Its core architectural concept is edge/cloud computing location transparency. This computational property allows data to be shared between different zones and to be processed at any of the edge nodes, mid nodes, or cloud nodes.

The concept of edge/cloud computing location transparency is realised by two of the entities in the SaT-IoT architecture, the IoT Data Flow Dynamic Routing Entity, and the Topology Management Entity (see Fig. 6.13). They support a cloud/fog programming model with the capability of managing the network topology at run-time while also providing the necessary monitoring capabilities to understand the usage pattern and capacity limitations of the infrastructure. While they provide the necessary capabilities to reconfigure the topologies and data flow, they lack the capability to derive the best-possible placement of the data processing logic. This is realised by integrating the RECAP Application Optimiser in the SAT-IoT platform.

Fig. 6.13
figure 13

SAT-IoT platform architectural model

6.4.3.2.1 IoT Topology Management Entity

IoT Data Flow Dynamic Routing is the cornerstone of SAT-IoT. It dynamically manages IoT data flows between processing nodes (cloud nodes, edge nodes, and smart devices). In addition, this entity includes a distributed temporary data storage system to support data streaming and local processing services. In this case study, data flows are both the sets of data sent by the cars (position, speed, fuel consumption, etc.) and the route calculation requests between two locations in the city.

The IoT Data Flow Dynamic Routing Entity comprises:

  • Data Streaming Management System: Provides the mechanisms to transfer IoT data flows directly from nodes (e.g. edge nodes or smart devices) to other internal or external services and applications that request them (on a publish/subscribe model).

  • Computing Location Transparency Support System: Wraps the RECAP Application Optimiser for its integration into the SAT-IoT platform.

  • Data Flow Routing Management System: Responsible for setting the routing of the data flows to the optimum computation node after inquiring about the best computation node for the data flow from the Computing Location Transparency Support System.

6.4.3.2.2 IoT Topology Management Entity

The IoT Topology Management Entity is responsible for the definition of an application network topology in every IoT system deployed by the platform. This application network topology defines which SAT-IoT entity communicates with which other SAT-IoT entities. The communication structure is based on the available underlying IT infrastructure (computation nodes and data network).

The application topology is defined as a graph of computing nodes and links between them, and it includes a variety of attributes like node features (CPU, Memory, etc.), data link features (bandwidth), geolocation of the node, use of resources (hardware and communication metrics), etc. With this definition, the system dynamically manages the physical hardware topologies, enables updating the logical structure of the topologies at any time, and includes a monitoring system that continuously provides the status of nodes and links in terms of performance metrics (consumption of CPU, memory, storage, bandwidth, etc., and also data flows crossing the network).

The three main functions of the Topology Management Entity are:

  • IoT Topology Definition: It enables the modelling of the IoT architecture as an enhanced graph in which nodes are the hardware elements with processing capabilities. The nodes in the graph are defined containing all their attributes (node type, CPU, RAM, location, etc.). Edges in the graph correspond to data links and have their attributes as well.

  • Topology Management: It is a set of services to query and modify the IoT topology definition to maintain the consistency between the physical installations and their definition in the platform. It supports the model of Edge/Cloud Computing Location Transparency supported by the platform.

  • Topology Monitoring: It continuously gathers and stores metrics of each node and edge. It also provides these metrics to other internal systems (IoT Topology Visualisation System or Embedded Applications) and external systems (third-party applications and systems).

6.4.3.2.3 Application Optimisation

To find the optimal location of the data processing logic, the optimiser needs to consider response latency, bandwidth consumption, storage, and other properties. Furthermore, the selection of the computation nodes might change dynamically as the conditions of the system may vary over the time (shared data, application requests, data volume, network disruptions, or any other relevant issue).

6.4.3.3 Implementation

For realising optimisation support, SAT-IoT integrates a RECAP application optimisation algorithm. Using this algorithm, SAT-IoT can decide, in real time, the optimum node of the IoT data network to process a given data flow. The integration of the application optimisation algorithm is implemented in the Computing Location Transparency Support System module, part of the IoT Data Flow Dynamic Routing Entity (see Fig. 6.14).

Fig. 6.14
figure 14

SAT IoT platform high-level conceptual architecture

The application optimisation algorithm uses IT resource optimisation techniques, graph theory (based on the topology graph definition), and machine learning processes to predict the needs of the system in the short term. The prediction considers the current state of the systems, e.g. metrics, IT resources used, links bandwidth consumption, application latencies, distribution of nodes across the topology, and the data flows involved in each node. A RECAP Non-Dominated Sorting Genetic Algorithm is used to calculate the optimum node to process the application data flows received in the last time period.

The Application Optimiser systematically receives the virtual topology and the data flows (route calculation requests and information about them) for the last time period. It then calculates a cost function to move the flows to each server and finally selects the node with the minimum value of the cost function. The application receives the node selected and requests the platform to configure the data flow routing to send the data flows to the optimum computation node.

The city traffic monitoring application makes use of the optimisation service provided by SAT-IoT and provides a user interface to execute the optimisation on demand. In a production setting, the Application Optimiser would be run automatically based on intervals. Every time the optimisation is executed, SAT-IoT automatically changes the virtual network routing configuration in order to send data flows to the optimum node for processing.

6.4.4 Validation Results

To validate the system, SAT-IoT runs a distributed Route Planning and City Traffic Monitoring application using a dataset of Cologne city traffic edited by the Simulation of Urban Mobility (SUMO) Eclipse project as an input. Software entities emulate cars moving in the city and send data such as position, velocity, and road conditions captured from sensors periodically.

The IoT platform and application have been deployed in a virtual infrastructure with a topology as shown in Fig. 6.15 where seven edge servers associated to ten areas of Cologne city are used (nine city zones and an additional zone to cover traffic close to those defined zones). Three mid nodes have been deployed to group sets of three areas, and a group of virtual servers acts as the cloud infrastructure. Runs cover traffic simulation of two hours.

Fig. 6.15
figure 15

Optimisation results

As discussed, SAT-IoT makes use of the RECAP Application Optimiser (see Fig. 6.13). Periodic optimisation is switched off and manual optimisation enabled to allow the user to execute the RECAP Application Optimiser on demand while the simulation scenario is running. This allows optimisations to be performed at different execution times where the conditions and status of the platform may vary. For instance, route requests and operational vehicles vary over time and executing the Application Optimiser at different points in time results in different optimisation results as shown at the top of Fig. 6.15. Here, the orange circle in the upper left diagram represents the optimal node for data processing at that point in time. Similarly, the chart at the upper right side shows the cost function for the selected node compared to cloud-based data processing.

In the lower left chart, Fig. 6.15 shows the values and results obtained from the optimisation process executed nine times during an experiment. In the first optimisation, the optimum destination node changes from the cloud to Node 86. The line chart on the right shows an immediate cost reduction. The table on the bottom left shows the cost saving/additional cost of moving the data to different nodes. In this case, the optimum node shows a reduction of 3311 cost points compared to moving the data to the cloud node. These results are evident in the bar chart at bottom right too.

Figure 6.16 plots the overall amount of data transferred per time unit. It compares a standard cloud-based processing approach with an approach using RECAP-Optimised message routing. As can be seen, it shows a significant reduction of transferred data and hence bandwidth consumption.

Fig. 6.16
figure 16

Number of records transferred for SAT-IoT running route planning and city traffic monitoring application using cloud-based processing and RECAP-optimised processing

6.4.5 Results

Implementation of the RECAP Application Optimiser (1) reduced bandwidth usage by up to 80% compared to a cloud-only processing of data, and (2) reduced the overall latency and improved the user experience by reducing the overall number of hops to send the data flows to the optimum processing node by up to 20%.

In summary, the benefits of the implementation of the RECAP Application Optimiser embedded in the SAT-IoT platform include (1) automated continuous optimisation; (2) enabling dynamic changes to computation nodes in an IoT network topology without administrator intervention to fulfil the efficiency criteria defined for the IoT system; and (3) global transparency across the entire IoT system, which together result in significantly reduced costs and increased quality of service.

6.5 Case Study in Capacity Planning: Big Data Analytics Search Engine

6.5.1 Introduction

This case study illustrates how components of the RECAP approach, namely data analytics as well as simulation and planning, can be used for capacity planning for and small-to-medium-sized enterprises.

Linknovate (LKN) is a Spanish SME that develops and markets a cloud-base data analytics and competitive intelligence platform and service. LKN’s primary market is in the US. LKN generates knowledge insights by aggregating large amounts of (heterogeneous) research and scientific data using data mining and data analytics techniques for their clients. At the time of writing, LKN had indexed over 20 million documents, over 30 million expert profiles, over 2 million entity profiles, and more than 200 million innovation topics.

LKN manages vast amounts of information through different offline and online layers. The offline layer, Data Acquisition, comprises several pre-processing components working in parallel over raw data to homogenise structure and identify entities and semantic relations. The online layer, Processing and Indexing, is done over a virtual cluster of search nodes based on ElasticSearch (ES). Finally, the Web and Search layer is where user queries execute several internal queries over LKN indices, retrieving the data to be displayed in the User Interface (UI). User queries are received by the virtual Nginx web server that also renders the results pages. The LKN platform is deployed on a heterogeneous technology stack on the Microsoft Azure cloud with three types of nodes: web processing nodes, database nodes, and the aforementioned index and search nodes. An overview of the LKN platform components is provided in Table 6.7.

Table 6.7 LKN platform components

6.5.2 Issues and Challenges

Small businesses typically operate in constrained business environments with a tension between scaling for growth and cashflow. While cloud computing provides significant benefits in terms of cashflow management and scalability, controlling consumption and managing complex cloud infrastructure with a small IT team are significant challenges. Small businesses may not be able to accommodate reactive approaches to infrastructure provisioning (given the elevated warm-up times) and could save costs and improve QoS by using predictive solutions. Such solutions should allow effective and efficient provisioning/deprovisioning of cloud capacity by predicting spikes in demand in the short- and medium term and enabling boot-up instances in advance thereby addressing consume pattern prediction by geographic region and accurately anticipating periodic time-based traffic patterns.

In this case study, LKN overprovision nodes in Azure to cope with unexpected or irregular request peaks by users with a focus on serving the Eastern US market. LKN would like to optimise their cloud resources to reduce the cost of overprovisioning and avoid platform replication in non-core geographic markets. RECAP Data Analytics and Simulation and Planning methodologies and tools were used to support LKN in the capacity planning.

6.5.3 Implementation

6.5.3.1 RECAP Data Analytics

6.5.3.1.1 Step 1: Exploratory Data Analysis
6.5.3.1.1.1 Web Server Error Analysis

Firstly, LKN data were evaluated from a quality perspective. Given that the workload is based on the number of user queries, the errors were evaluated (number of invalid requests) reported by the web server as per Table 6.8 below.

Table 6.8 Statistics of the response codes returned by the LKN search engine

Although 78.78% of the queries were successfully answered by the search engine, the number of errors is very high for this kind of service.

6.5.3.1.1.2 Request Source Analysis

In a second step, the source of all requests was analysed and ordered by the number of requests. Table 6.9 below presents data based on the first 10 entries.Footnote 2 45% of the requests are originated from a few IP addresses. These IPs correspond to web-spider bots from large search companies, e.g. Google and Yandex. As this provides visibility for LKN in search engine results, no remediation action was taken.

Table 6.9 The top 10 IP addresses directing the largest number of requests to the LKN search engine
6.5.3.1.1.3 Response Size and Response Time

Figure 6.17 shows a histogram of the response volume of the LKN search engine. Figure 6.17(b) presents a histogram of the (total) time that the search engine requires to provide an answer to user queries. The correlation between the response size and the response time was also studied and is shown in Fig. 6.17(c). The Pearson correlation coefficient is 0.18. If only 200 (OK) requests are considered, it is 0.20. Both 0.18 and 0.20 suggest a positive (although weak) correlation between both values.

Fig. 6.17
figure 17

(a), (b), and (c): Histograms of the distribution of the responses, response time, and scatter plot of the response size and time for the LKN search engine

6.5.3.1.1.4 Number of Requests

The number of requests has also been characterised through a time series with the number of requests that the server receives aggregated over intervals of 30 minutes. This time series is the target workload that is analysed and modelled as part of the RECAP methodology. Peaks in this period can be explained by increased media attention during the period (Fig. 6.18).

Fig. 6.18
figure 18

Time series of the LKN’s search engine workload (data aggregated over windows of 30 minutes)

6.5.3.2 Workload Predictor Model

From experience, the time to deploy a new data node in Azure clusters is about 30 minutes. The original dataset was aggregated in periods of 30 minutes, and a new feature, number of requests, was derived. Predicting the number of servers required for the next period of 30 minutes (workload prediction) to deal with the expected user requests is the goal of the model.

As a preliminary step before fitting a model to predict future workloads, the stationarity of the time series was examined. A visual inspection of a moving average and a moving standard deviation, together with a decomposition of the series in trends + cycles + noise, suggests a stationary time series. This intuition has been confirmed with a Dickey-Fuller test. The coefficients of the autoregressive integrated moving average (ARIMA) were estimated using an autocorrelation function (autoregressive part) and a partial autocorrelation function (for the moving average) where the already identified components were removed. The final ARIMA model trained corresponds to an autoregressive part of four periods, and a moving average of six periods, without requiring the integration of the original time series.

Figure 6.19 presents a sample dashboard with the Workload Predictor and the Application Modeller for LKN. The dashboard is composed of three independent but synchronised panes. The “Workload” pane, displayed in light blue, presents the actual workload (number of requests during each 30-minute interval) of the search engine, along with the forecast number of servers required to deal with the predicted workload (in black). The “Capacity Planning” pane presents the overprovisioning of resources deployed to deal with the actual workloads. The current overprovisioning of the servers in production used by LKN is displayed in light blue, while the overprovisioning given the RECAP models is displayed in dark blue together with the underprovisioning in red. The grey display depicts a conservative model that does not underprovision resources. Finally, the “Servers and Location” pane presents the recommended number of servers and their geographical locations, as they are predicted by the application model.

Fig. 6.19
figure 19

Workload predictor dashboard

RECAP ran a simulation of the LKN workload based on a historical dataset collected at the production server for a period of one month (August 2017). Based on the collected data, LKN was overprovisioning during that period of time by an average number of 13.8 cores of Azure DS12 v2 i.e. 86.6% of overprovisioning of data processing capacity. Applying the RECAP models would reduce overprovisioning to 3.5 cores, or the equivalent of 60% overprovisioning.

6.5.3.3 RECAP Simulation and Planning Mode

The RECAP Simulation Framework supports a number of features that can help in ES-based system deployment and provisioning decisions. These include:

  • Modelling and simulation of a distributed data flow with a hierarchical architecture;

  • Custom policy implementation for distributing workload in the hierarchical architecture;

  • Synchronous communication between search engine components for data aggregation; and

  • Flexible modelling that can be easily adapted to integrate with other CloudSim extensions.

6.5.3.3.1 Modelling

Figure 6.20 shows the online virtual layers of the LKN search engine considered in the implementation of the RECAP Simulation Framework. As discussed earlier, the deployed LKN search service stack consists of a web server where the users input their queries and an ES cluster which is responsible for the search and returning the response to the user query. The ES cluster consists of an ES client node and data nodes. The ES node is responsible for: (1) passing and distributing the queries among the data nodes; (2) coordinating and aggregating the search results of different data nodes; (3) and returning the query result to the web server, which in turn returns it to the user. The data nodes are responsible for storing and processing old and fresh data.

Fig. 6.20
figure 20

LKN conceptual ElasticSearch (ES) architecture

A simulation model was built to reflect the behaviour of a real ES-based system deployed in a public cloud based on the LKN workload data as a reference. An ES-based search engine was then modelled and simulated using a Discrete Event Simulation (DES) approach. To do so, CloudSim, a widely used open source DES platform, was extended with the simulation model and then compared with KPI traces collected from LKN.

Figure 6.21 illustrates the ES workload flow. Within CloudSim modelling concepts, a cloudlet represents a task submitted to a cloud environment for processing. When a query is launched, a set of cloudlets is generated and executed in sequential manner. The first cloudlet is executed at a web server then the second cloudlet is executed at the ES node. From the ES node, a set of cloudlets (which is less or equal to the number of data nodes) is distributed and executed at data nodes. Next, another cloudlet is executed again at the ES node to merge the partial results coming back from the data nodes. Finally, a last cloudlet goes from the ES node to the web server as a response to the user query.

Fig. 6.21
figure 21

ElasticSearch (ES) workload flow

6.5.3.3.2 Results

The simulated response time of a query was compared to its actual time as collected from real system traces. A subset of 100 valid queries was extracted from the data set used. Figure 6.22 compares actual and simulation query response times across the 100 queries. As one can see, the actual query response times and the simulation query response times are very close and highly positively correlated across all the 100 queries tested.

Fig. 6.22
figure 22

Comparison of actual and simulation query response times

The performance of the LKN system was analysed by running the simulation with different workloads (query traffic) to see how much traffic the LKN system could handle. Query response time was monitored while varying the number of queries per second (q/s) received by the system. Figure 6.23 is a box plot (min, max, lower quartile, upper quartile) that shows the query response time based on the number of queries per second the system receives.

Fig. 6.23
figure 23

LKN system performance under different traffic scenarios

With query traffic of up to 80 q/s, the query response time for all the queries is the same and it is equal to having one q/s. That means the system is capable of handling 80 q/s with no waiting time. Between 80 q/s and 120 q/s, a slight increase in the response time appears. However, this increase affects all the queries in the same way, i.e. there is no difference in response time between the queries. As we increase the query traffic beyond 120 q/s, a divergence in query response times becomes apparent. Between 130 q/s and 170 q/s, the system manages to execute several queries within a short time by delaying the excess of queries; however, with the increase in query traffic beyond 170 q/s, the system fails to execute even a single query in a short time.

6.5.4 Results

The analysis run for this case study has proven valuable in multiple ways. First, LKN was able to gain a better understanding of infrastructure planning, deployment, anomaly detection. Similar, workload prediction models estimate the potential cost savings due to improved resource consumption of 26.6%.

Using the RECAP DES simulator, it was possible to provide an insight for LKN into capacity planning in that it identifies thresholds at which point LKN’s QoS starts degrading and additional resources must be provisioned. LKN can now use these data to reduce overprovisioning and at the same time set specific rules for scaling up and down in a cost-effective manner.

All these insights resulted in LKN changing their deployment strategy moving to a more advanced infrastructure configuration using only two data nodes (instead of nine) with NVMe (non-volatile memory express) storage.