Abstract
Conventional electrical circuit leakage fault data acquisition technology of leakage fault information collection, Failure to eliminate noise interference, resulting in failure to achieve real-time acquisition of circuit leakage fault data. There is a problem of low data accuracy and large noise interference, therefore put forward based on signal trigger electrical wiring leakage fault data automatic acquisition methods. Electrical wiring leakage fault detection based on signal trigger automatic acquisition mechanism, structures, acquisition model system, the acquisition model system hardware, electrical wiring to realize automatically leakage failure data acquisition model building; Automatically determine the leakage failure data acquisition software workflow, based on the leakage current fault detection algorithm and software anti-interference design, implementation is based on signal trigger automatic electric circuit leakage failure data collection. The experimental data show that the proposed automatic collection method is 35.24% more accurate than the traditional collection method, which is suitable for automatic collection of leakage fault data of different electrical circuits at different times.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Han, B.Z., Yu, L.F.: Fault diagnosis method of actuator based on Kalman filter bank. Comput. Simul. 30(2), 93–96 (2013)
Chen, Y.H., Deng, X.G.: Improvement and simulation of remote nuclear radiation data network acquisition method. Comput. Simul. 33(6), 274–277 (2016)
Duan, Z.M., Li, C., Cong, P.T., et al.: Remote fault signal acquisition method for fan fault detection based on STM32F407. Instrum. Technol. Sens. 6, 176–178 (2017)
Wu, Z., Zhang, J.C.: Application of improved EEMD data fusion method in bearing fault diagnosis. J. Beijing Jiaotong Univ. 40(3), 43–49 (2016)
Wu, H.L., Bai, Z.Q., Zhang, Y., et al.: Design and implementation of low frequency radio astronomy signal acquisition circuit based on modulated broadband converter. J. Comput. Appl. 38(2), 610–614 (2018)
Sun, S.G., Zhang, Q., Du, T.X., et al.: Study on the method of evaluating the failure degree of low-voltage universal breaker based on vibration signal. Proc. CSEE 37(18), 5473–5482 (2017)
Zhou, Y.T., Jiang, G.D., Tao, T., et al.: Multi-card synchronous acquisition method based on EnDat data transmission cycle. Combined Mach. Tool Autom. Manuf. Technol. 12, 9–12 (2016)
Li, C., Cong, P.T., Duan, Z.M., et al.: Vibration signal acquisition method based on adaptive sampling frequency and AD7606. Instrum. Technol. Sens. 7, 116–120 (2017)
Yang, K., Zhang, Q.C., Yang, J.H., et al.: Fault diagnosis method for series arc based on fractal dimension and support vector machines. Electrotechnics 31(2), 70–77 (2016)
Zhang, L.P., Geng, X.R., Shi, D.Y.: Research on low voltage arc fault identification method based on EMD and ELM. J. Electr. Mach. Control 20(9), 54–60 (2016)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 ICST Institute for Computer Sciences, Social Informatics and Telecommunications Engineering
About this paper
Cite this paper
Qu, Mf., Ma, Db. (2019). Signal-Triggered Automatic Acquisition Method for Electrical Leakage Fault Data of Electrical Circuits. In: Gui, G., Yun, L. (eds) Advanced Hybrid Information Processing. ADHIP 2019. Lecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering, vol 302. Springer, Cham. https://doi.org/10.1007/978-3-030-36405-2_38
Download citation
DOI: https://doi.org/10.1007/978-3-030-36405-2_38
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-36404-5
Online ISBN: 978-3-030-36405-2
eBook Packages: Computer ScienceComputer Science (R0)