Skip to main content

Reduced Optical Path Length in the Vastus Lateralis During Ramp Cycling Exercise

  • Chapter
  • First Online:
Oxygen Transport to Tissue XLI

Abstract

Near-infrared time-resolved spectroscopy (NIRTRS) can quantitatively evaluate mean optical path length (MPL). Since an increase in optical absorbers in the NIR region (e.g. an increase in deoxygenated hemoglobin during exercise) would shorten the MPL, the NIRS measurement area may vary depending on physical and physiological characteristics of the measurement region and/or the exercise intensity. The aim of this study was to examine the changes in MPL measured by NIRTRS during ramp cycling exercise between fat layer thickness-matched subjects with different aerobic capacities. Healthy control (CON, n = 8) and endurance-trained males (TR, n = 8) performed ramp cycling exercise until exhaustion. Deoxygenated hemoglobin concentration (Deoxy-Hb), total hemoglobin concentration (Total-Hb) and oxygenated hemoglobin concentration (Oxy-Hb) were evaluated by a three-wavelength NIRTRS system. MPL in each wavelength (MPL760, MPL800 and MPL830) was monitored continuously. With increasing exercise intensity, Total- and Deoxy-Hb significantly increased and Oxy-Hb decreased in both groups. Total- and Oxy-Hb during exercise were significantly higher in TR than CON (P < 0.05, P < 0.01, respectively). Furthermore, Deoxy-Hb also tended to be higher in TR than CON (P = 0.07). In addition, MPL at all wavelengths significantly shortened with an increase in exercise intensity, with no differences between CON and TR. In particular, MPL760 at peak exercise shortened more than 10% compared to the start of exercise in both groups, even though MPL830 decreased only a few per cent. These findings suggest that the NIRS measurement area may be reduced during ramp cycling exercise due to shortened MPL. Additionally, the changes in MPL may be especially greater at 760 nm than at the other wavelengths due to greater changes in Deoxy-Hb during exercise. Furthermore, this study indicates that the measurements of muscle deoxygenation using continuous-wave NIRS can be less accurate since they are significantly affected by changes in the optical path length.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 119.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 159.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Grassi B, Quaresima V (2016) Near-infrared spectroscopy and skeletal muscle oxidative function in vivo in health and disease: a review from an exercise physiology perspective. J Biomed Opt 21(9):091313

    Article  Google Scholar 

  2. Takagi S (2016) Skeletal muscle oxygen dynamics and peak aerobic capacity. J Phys Fitness Sports Med 5(5):379–383

    Article  Google Scholar 

  3. Delpy DT et al (1988) Estimation of optical pathlength through tissue from direct time of flight measurement. Phys Med Biol 33(12):1433–1442

    Article  CAS  Google Scholar 

  4. Ferrari M et al (1992) Time-resolved spectroscopy of the human arm. J Photochem Photobiol B Biol 16:141–153

    Article  CAS  Google Scholar 

  5. Ferreira LF et al (2007) Effects of assuming constant optical scattering on measurements of muscle oxygenation by near-infrared spectroscopy during exercise. J Appl Physiol 102:358–367

    Article  CAS  Google Scholar 

  6. Duncan A et al (1995) Measurement of changes in optical pathlength through human muscle during cuff occlusion on the arm. Opt Laser Technol 27(4):269–274

    Article  Google Scholar 

  7. Patterson MS et al (1989) Time resolved reflectance and transmittance for the noninvasive measurement of tissue optical properties. Appl Opt 28(12):2231–2236

    Article  Google Scholar 

  8. Zoladz JA et al (2005) Capillary density and capillary-to-fibre ratio in vastus lateralis muscle of untrained and trained men. Folia Histochem Cyto 43(1):11–17

    CAS  Google Scholar 

Download references

Acknowledgments

The authors are grateful to Andrea Hope for revision of this manuscript. We also thank Mikiko Anjo and Ayaka Kime (Tokyo Medical University, Japan) for their helpful technical assistance. This study was supported by JSPS KAKENHI Grant Number 16 K01735.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ryotaro Kime .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Endo, T. et al. (2020). Reduced Optical Path Length in the Vastus Lateralis During Ramp Cycling Exercise. In: Ryu, PD., LaManna, J., Harrison, D., Lee, SS. (eds) Oxygen Transport to Tissue XLI. Advances in Experimental Medicine and Biology, vol 1232. Springer, Cham. https://doi.org/10.1007/978-3-030-34461-0_30

Download citation

Publish with us

Policies and ethics