Abstract
Production of different kind of parts has increasing character. They are different according to materials, shapes, production technology and accuracy. Possibilities of their quality and accuracy control have to taken into consideration. In addition to optical (non – contact method) and contact (CMM) methods there are applied progressive technologies which bring new opportunities into the metrology processes. One of them is application of X - ray beam in measurement process. Computed tomography finds application in the field of different parts quality evaluation. This new method has many unexamined areas which are necessary to research. One of them is effect of voxel size on quality and accuracy of achieved model.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Kruth, J.P., Bartscher, M., Carmignto, S., Schmitt, R., De Chiffre, L., Weckenmann, A.: Computed tomography for dimensional metrology. CIRP Ann. Manuf. Technol. 60, 821–842 (2011)
Ambrose, J., Hounsfield, G.: Computerized Transverse Axial Tomography. Br. J. Radiol. 46, 1023–1047 (1973)
Reimers, P., Goebbels, J.: New possibilities of non-destructive evaluation by X-ray computed tomography. Mater. Eval. 41, 732–737 (1983)
Werth Messtechnik (2011). www.werth.de/de/unser-angebot/
Mitchell, K.W.: A generalized approach to wall thickness measurements in CT images. In: Topical Proceedings of Industrial Computerized Tomography, pp. 120–124. ASNT (1989). ISBN 0–931403-89-8
GE/phoenix Prufbericht, 3D Prazisionsprufung CT, Prufbericht zur Bestimmung der Messgenauigkeit von CT-Systemen, pp. 1–8 (2009)
http://werthinc.com/computer-tomography-principle-x-ray-tomography/
Kato, A., Ohno, N.: Construction of three-dimensional tooth model by micro-computed tomography and application for data sharing (2009). https://www.ncbi.nlm.nih.gov/pubmed/18386082
ZEISS 2015 METROTOM 1500: Návod k obsluze. ISBN 61212-7090112
https://static.industryarena.com/files/i/143/505/61366e2dadeace5fe0242a67d606edcb_MW_1200_.png
Acknowledgment
This work was supported by the Slovak Research and Development Agency under the Contract no. APVV-18-0418.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this paper
Cite this paper
Kritikos, M. (2020). Effect of the Voxel Size on the Final Scan Accuracy in Computed Tomography. In: Durakbasa, N., Gençyılmaz, M. (eds) Proceedings of the International Symposium for Production Research 2019. ISPR ISPR 2019 2019. Lecture Notes in Mechanical Engineering. Springer, Cham. https://doi.org/10.1007/978-3-030-31343-2_37
Download citation
DOI: https://doi.org/10.1007/978-3-030-31343-2_37
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-31342-5
Online ISBN: 978-3-030-31343-2
eBook Packages: EngineeringEngineering (R0)