Skip to main content

Kinematic Design of a Double Pantographic Mechanism for the Intracranial Echography on Incubated Newborns

  • Conference paper
  • First Online:
Robotics and Mechatronics (ISRM 2019)

Part of the book series: Mechanisms and Machine Science ((Mechan. Machine Science,volume 78))

Included in the following conference series:

  • 1247 Accesses

Abstract

Some newborn babies require particular cares and are therefore placed in neonatal incubators. Intracranial ultrasound examinations are regularly performed in order to monitor the development of their brain. Due to the repetitivity and uncomfortability associated with this clinical task, the design of a robotic system capable of performing this task is proposed. The manipulation of an ultrasound probe inside a neonatal incubator is studied using a motion capture system. The kinematic specifications associated with this clinical task are established. A mechanical architecture based on two combined pantographic linkages is proposed. One pantographic mechanism performs the linear positioning of the end effector around a center of rotation. The orientation of the ultrasound probe around another center of rotation is mainly provided by a second pantographic linkage. The forward and inverse kinematic models are calculated to study the linear and angular positioning of the mechanism. The trajectories measured during the motion capture experiments are then tested on the mechanism to validate its suitability with the intracranial echography on newborns inside incubators.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Slovis, T.L., Kuhns, L.R.: Real-time sonography of the brain through the anterior fontanelle. Am. J. Roentgenol. 136, 277–286 (1981)

    Article  Google Scholar 

  2. Pape, K.E., Cusick, G., Blackwell, R.J., Houang, M.T.W., Sherwood, A., Thorburn R.J., Reynolds, E.O.R: Ultrasound detection of brain damage in preterm infants. Lancet 313(8129), 1261–1264 (1979)

    Google Scholar 

  3. Hsieh, W.-S., Jeng, S.-F., Hung, Y.-L., Chen, P.-C., Chou, H.-C., Tsao, P.-N.: Outcome and hospital cost for infants weighing less than 500 grams: a tertiary centre experience in Taiwan. J. Paediatr. Child Health 43(9), 627–631 (2007)

    Article  Google Scholar 

  4. Salcudean, S.E., Bell, G., Bachmann, S., Zhu, W.H., Abolmaesumi, P., Lawrence, P.D.: Robot-assisted diagnostic ultrasound-design and feasibility experiments. In: Medical Image Computing and Computer-Assisted Intervention, MICCAI 1999, pp. 1062–1071 (1999)

    Chapter  Google Scholar 

  5. Mitsuishi, M., Warisawa, S., Tsuda, T., Higuchi, T., Koizumi, N., Hashizume, H., Fujiwara, K.: Remote ultrasound diagnostic system. In: IEEE International Conference on Robotics & Automation, ICRA 2001, pp. 1567–1574 (2001)

    Google Scholar 

  6. Vilchis, A., Troccaz, J., Cinquin, P., Masuda, K., Pellissier, F.: A new robot architecture for tele-echography. IEEE Trans. Robot. Autom. Spec. Issue Med. Robot. 19(5), 922–926 (2003)

    Article  Google Scholar 

  7. Najafi, F.: Design and prototype of a robotic system for remote palpation and ultrasound imaging. M.Sc. Dissertation, University of Manitoba. Available as Report 20104, University of Manitoba Library MSpace (2004)

    Google Scholar 

  8. Lessard, S., Bigras, P., Bonev, I.A.: A new medical parallel robotic and its static balancing optimization. ASME J. Med. Device 1(4), 272–278 (2007)

    Article  Google Scholar 

  9. Najafi, F., Sepehri, N.: A robotic wrist for remote ultrasound imaging. Mech. Mach. Theory 46(8), 1153–1170 (2011)

    Article  Google Scholar 

  10. Masuda, K., Miyazaki, W, Sugano, Y., Yoshinaga, T.: Effectiveness of tele-echography system with and without robotics according to patient circumstances. In: Proceedings of the 3rd International Conference on E-Health and Bioengineering, EHB 2011, Iasi, Romania, 24–26 November 2011

    Google Scholar 

  11. Nakadate, R., Matsunaga, Y., Solis, J., Takanishi, A., Minagawa, E., Sugawara, M., Niki, K.: Development of a robot assisted carotid blood flow measurement system. Mech. Mach. Theory 46(8), 1066–1083 (2011)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Terence Essomba .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Essomba, T., Hsieh, JY. (2020). Kinematic Design of a Double Pantographic Mechanism for the Intracranial Echography on Incubated Newborns. In: Kuo, CH., Lin, PC., Essomba, T., Chen, GC. (eds) Robotics and Mechatronics. ISRM 2019. Mechanisms and Machine Science, vol 78. Springer, Cham. https://doi.org/10.1007/978-3-030-30036-4_39

Download citation

Publish with us

Policies and ethics