The paper describes the development of electrode system and blood glucose measuring circuit for glucose analysis. Measuring blood glucose levels is today one of the standards of medical procedures that determine the physiological state of a person. The task of the work was to implement the measuring system, to test the functionality of the whole system, the measurement tests were carried out and the measured data were subsequently processed statistically. In designing and constructing the electrode system, the resistive principle of measurement of non-electrical quantities was applied because the system focuses on the measurement of the concentration of a certain substance in the liquid. These are electrolytic sensors using gold electrodes. The part that deals with the construction of the electrical measuring circuit has determined the conditions that the circuit must meet. For this reason, a micro-ammeter was designed to provide the source voltage, measure the current and convert it back to a suitable magnitude. The current measured by the circuit is proportional to the concentration of glucose in the solution. Glucose oxidase enzyme was used to distinguish glucose molecules in the blood and determine its concentration, which, together with the supply of the required voltage, provides useful chemical reactions. Based on the processed data, it is possible to evaluate the constructed system and lay the foundations for further development of the issue.
Keywords
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
Comeaux, R., Novotny, P.: Biosensors: Properties, Materials and Applications. Biotechnology in Agriculture, Industry and Medicine Series. Nova Science Publishers, New York (2009). ISBN 978-1-60741-617-3
Clarke, S.F., Foster, J.R.: A history of blood glucose meters and their role in self-monitoring of diabetes mellitus. Br. J. Biomed. Sci. 69(2), 83 (2012)
Chang, T.M.S.: Biomedical Applications of Immobilized Enzymes and Proteins. Springer Science & Business Media (2013)
Holzinger, U., et al.: Real-time continuous glucose monitoring in critically ill patients: a prospective randomized trial. Diabetes care 33(3), 467–472 (2010)
Pickup, J.C., ed.: Insulin Pump Therapy and Continuous Glucose Monitoring. Oxford University Press, Oxford (2009). ISBN 978-0-19-956860-4
Eggins, B.R.: Chemical Sensors and Biosensors. Wiley, Chichester (2002). ISBN 0-471-89913-5
Hermanson, G.T.: Bioconjugate Techniques, 2nd edn. Academic Press, San Diego (2008). ISBN 978-0-12-370501-3
Bugg, T.D.H.: Introduction to Enzyme and Coenzyme Chemistry, 3rd ed. Wiley, Hoboken (2013). ISBN 9781118348994
Langendam, M., et al.: Continuous glucose monitoring systems for type 1 diabetes mellitus. The Cochrane Library (2012)
Rodbard, D.: Continuous glucose monitoring: a review of successes, challenges, and opportunities. Diab. Technol. Ther. 18(S2), S2-3–S2-13 (2016)
Nichols, S.P., et al.: Biocompatible materials for continuous glucose monitoring devices. Chem. Rev. 113(4), 2528–2549 (2013)
Wagner, J., Tennen, H., Wolpert, H.: Continuous glucose monitoring: a review for behavioral researchers. Psychosom. Med. 74(4), 356 (2012)
English, B.P., et al.: Ever-fluctuating single enzyme molecules: Michaelis-Menten equation revisited. Nat. Chem. Biol. 2(2), 87–94 (2006)
Purich, D.L.: Enzyme Kinetics: Catalysis & Control: A Reference of Theory and Best-Practice Methods. Elsevier/Academic Press, Amsterdam (2010). ISBN 9780123809247
Fiedorová, K.: Návrh elektrody pro měření koncentrace glukózy v krvi. Ostrava. Dostupné z: http://hdl.handle.net/10084/119180. Diplomová práce. Vysoká škola báňská - Technická univerzita Ostrava (2017). [cit. 2018-06-25]
Acknowledgment
The work and the contributions were supported by the project SV4508811/2101 ‘Bi- medicínské inženýrské systémy XIV’. This study was supported by the research project The Czech Science Foundation (GACR) 2017 No. 15330/16/AGR Investment evaluation of medical device development run at the Faculty of Informatics and Management, University of Hradec Kralove, Czech Republic. This study was supported by the research project The Czech Science Foundation (TACR) ETA No. TL01000302 Medical devices development as an effective investment for public and private entities.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this paper
Cite this paper
Fiedorova, K., Augustynek, M. (2020). Proposal of Electrode System for Measuring Level of Glucose in the Blood. In: Zelinka, I., Brandstetter, P., Trong Dao, T., Hoang Duy, V., Kim, S. (eds) AETA 2018 - Recent Advances in Electrical Engineering and Related Sciences: Theory and Application. AETA 2018. Lecture Notes in Electrical Engineering, vol 554. Springer, Cham. https://doi.org/10.1007/978-3-030-14907-9_5
Download citation
DOI: https://doi.org/10.1007/978-3-030-14907-9_5
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-14906-2
Online ISBN: 978-3-030-14907-9
eBook Packages: EngineeringEngineering (R0)