Abstract
Continuous glucose monitors (CGMs) are minimally invasive sensors that detect blood glucose levels (usually in patients with diabetes) at high frequency. The devices produce considerable volumes of sensor data when used for weeks and months. We consider the following research question: is it possible to uniquely identify a patient from a fragment of their CGM data? That is, supposing a patient’s medical records are stored in a database along with a large sample of their CGM data, could an attacker with a much smaller sample of data from a different time period match the two time series and positively identify the patient? If the answer is yes, then significant patient privacy concerns are raised since many health records are now stored online. Our investigations using existing public CGM datasets reveal that many subjects can be uniquely identified using a simple nearest neighbour-based analysis approach.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Bailey, T.S., Chang, A., Christiansen, M.: Clinical accuracy of a continuous glucose monitoring system with an advanced algorithm. J. Diabetes Sci. Technol. 9(2), 209–214 (2014)
Bruen, D., Delaney, C., Florea, L., Diamond, D.: Glucose sensing for diabetes monitoring: recent developments. Sensors 17(8), 1866 (2017)
Buckingham, B., et al.: Effectiveness of early intensive therapy on \(\beta \)-cell preservation in type 1 diabetes. Diabetes Care 36, 4030 (2013)
Cappon, G., Acciaroli, G., Vettoretti, M., Facchinetti, A., Sparacino, G.: Wearable continuous glucose monitoring sensors: a revolution in diabetes treatment. Electronics 6(3), 65 (2017)
Hassanalieragh, M., et al.: Health monitoring and management using Internet-of-Things (IoT) sensing with cloud-based processing: opportunities and challenges. In: 2015 IEEE International Conference on Services Computing (SCC), pp. 285–292. IEEE (2015)
Kovatchev, B.P., Cox, D.J., Gonder-Frederick, L.A., Clarke, W.: Symmetrization of the blood glucose measurement scale and its applications. Diabetes Care 20(11), 1655–1658 (1997)
Kovatchev, B.P., Otto, E., Cox, D., Gonder-Frederick, L., Clarke, W.: Evaluation of a new measure of blood glucose variability in diabetes. Diabetes Care 29(11), 2433–2438 (2006)
Mauras, N., et al.: A randomized clinical trial to assess the efficacy and safety of real-time continuous glucose monitoring in the management of type 1 diabetes in young children aged 4 to \(<\)10 years. Diabetes Care 35, 204 (2011)
PĂ©rez-GandĂa, C., et al.: Decision support in diabetes care: the challenge of supporting patients in their daily living using a mobile glucose predictor. J. Diabetes Sci. Technol. 12(2), 243–250 (2018)
Rodbard, D.: Continuous glucose monitoring: a review of recent studies demonstrating improved glycemic outcomes. Diabetes Technol. Ther. 19(S3), S25 (2017)
The Nightscout Foundation: About the Nightscout Data Commons on Open Humans (2014). http://www.nightscoutfoundation.org/data-commons/
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this paper
Cite this paper
Mayo, M., Yogarajan, V. (2019). A Nearest Neighbour-Based Analysis to Identify Patients from Continuous Glucose Monitor Data. In: Nguyen, N., Gaol, F., Hong, TP., Trawiński, B. (eds) Intelligent Information and Database Systems. ACIIDS 2019. Lecture Notes in Computer Science(), vol 11432. Springer, Cham. https://doi.org/10.1007/978-3-030-14802-7_30
Download citation
DOI: https://doi.org/10.1007/978-3-030-14802-7_30
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-14801-0
Online ISBN: 978-3-030-14802-7
eBook Packages: Computer ScienceComputer Science (R0)