Cone beam computed tomography (CBCT) is increasingly popular when gathering initial patient imaging records for diagnosis and treatment planning. Although traditional two-dimensional panoramic or cephalometric radiographs can provide sufficient information to perform treatment in most cases, clinicians have become aware of the distortion inherent with these radiographs that can affect angular and linear measurements and, more importantly, tooth location and tooth-bone-jaw relationships.
A problem with CBCT technology is that its routine use poses a health risk as a source of ionizing radiation, especially in orthodontic patients who are mostly growing patients, preadolescent, and adolescent.
But what if there was a way to reduce the radiation dose and still reap the benefits of this technology to better serve our patients? This chapter will discuss dose adjustment methods used in the medical arena and their applications in the dental profession, with special focus on orthodontics.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
American Association of Orthodontists. Statement on the role of CBCT in orthodontics. Creve Coeur, MO: American Association of Orthodontists; 2010. p. 26-10H.
American Dental Association Council on Scientific Affairs. The use of cone beam computed tomography in dentistry: an advisory statement from the American Dental Association Council on Scientific Affairs. J Am Dent Assoc. 2012;143:899–902.
American Academy of Oral and Maxillofacial Radiology. Clinical recommendations regarding use of cone beam computed tomography in orthodontics. Position statement by the American Academy of Oral and Maxillofacial Radiology. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013;116:238–57. https://doi.org/10.1016/j.OOOO.2013.06.002.
Ludlow JB. A manufacturer’s role in reducing the dose of cone beam computed tomography examinations: effect of beam filtration. Dentomaxillofac Radiol. 2011;40:115–22. https://doi.org/10.1259/dmfr/31708191.
Qiu W, Pengpan T, Smith ND, Soleimani M. Evaluating iterative algebraic algorithms in terms of convergence and image quality for cone beam CT. Comput Methods Prog Biomed. 2013;109:313–22. https://doi.org/10.1016/j.cmpb.2012.09.006.
Park JC, Song B, Kim JS, Park SH, Kim HK, Liu Z, et al. Fast compressed sensing-based CBCT reconstruction using Barzilai–Borwein formulation for application to on-line IGRT. Med Phys. 2012;39:1207–17. https://doi.org/10.1118/1.3679865.
Walker L, Enciso R, Mah J. Three-dimensional localization of maxillary canines with cone-beam computed tomography. Am J Orthod Dentofac Orthop. 2005;128:418–23.
Hatcher DC, Miller A, Peck JL, Sameshima GT, Worth P. Mesiodistal root angulation using panoramic and cone beam CT. Angle Orthod. 2007;77:206–13.
Monnerat C, Restle L, Mucha JN. Tomographic mapping of mandibular interradicular spaces for placement of orthodontic mini-implants. Am J Orthod Dentofac Orthop. 2009;135:428–9.
Baik HS, Kim KD, Lee KJ, Park SH, Yu HS. A proposal for a new analysis of craniofacial morphology by 3-dimensional computed tomography. Am J Orthod Dentofac Orthop. 2006;129:600. e23–600. e34.
Nakajima A, Arai Y, Dougherty H Sr, Homme Y, Sameshima GT, Shimizu N. Two- and three-dimensional orthodontic imaging using limited cone beam–computed tomography. Angle Orthod. 2005;75:895–903.
Larson BE. Cone-beam computed tomography is the imaging technique of choice for comprehensive orthodontic assessment. Am J Orthod Dentofac Orthop. 2012;141:402–4., 406 passim. https://doi.org/10.1016/j.ajodo.2012.02.009.
Halazonetis DJ. Cone-beam computed tomography is not the imaging technique of choice for comprehensive orthodontic assessment. Am J Orthod Dentofac Orthop. 2012;141:403–5., 407 passim. https://doi.org/10.1016/j.ajodo.2012.02.010.
Wiesent K, Barth K, Navab N, Durlak P, Brunner T, Schuetz T, et al. Enhanced 3-D-reconstruction algorithm for C-arm systems suitable for interventional procedures. IEEE Trans Med Imaging. 2000;19:391–403.
Lauritsch G, Boese J, Wigström L, Kemeth H, Fahrig R. Towards cardiac C-arm computed tomography. IEEE Trans Med Imaging. 2006;25:922–34.
Wallace MJ, Kuo MD, Glaiberman C, Binkert CA, Orth RC, Soulez G. Three-dimensional C-arm cone-beam CT: applications in the interventional suite. J Vasc Interv Radiol. 2008;19:799–813. https://doi.org/10.1016/j.jvir.2008.02.018.
Orth RC, Wallace MJ, Kuo MD. C-arm cone-beam CT: general principles and technical considerations for use in interventional radiology. J Vasc Interv Radiol. 2008;19:814–20. https://doi.org/10.1016/j.jvir.2008.02.002.
Grass M, Koppe R, Klotz E, Proksa R, Kuhn M, Aerts H, et al. Three-dimensional reconstruction of high contrast objects using C-arm image intensifier projection data. Comput Med Imaging Graph. 1999;23:311–21.
Siewerdsen JH, Moseley DJ, Burch S, Bisland SK, Bogaards A, Wilson BC, et al. Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery. Med Phys. 2005;32:241–54.
Hott JS, Deshmukh VR, Klopfenstein JD, Sonntag VK, Dickman CA, Spetzler RF, et al. Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases. Neurosurgery. 2004;54:1131–7.
De Vos W, Casselman J, Swennen G. Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: a systematic review of the literature. Int J Oral Maxillofac Surg. 2009;38:609–25. https://doi.org/10.1016/j.ijom.2009.02.028.
Jaffray DA, Siewerdsen JH, Wong JW, Martinez AA. Flat-panel cone-beam computed tomography for image-guided radiation therapy. Int J Radiat Oncol Biol Phys. 2002;53:1337–49.
Oldham M, Létourneau D, Watt L, Hugo G, Yan D, Lockman D, et al. Cone-beam-CT guided radiation therapy: a model for on-line application. Radiother Oncol. 2005;75:271–8.
Smitsmans MH, De Bois J, Sonke J-J, Betgen A, Zijp LJ, Jaffray DA, et al. Automatic prostate localization on cone-beam CT scans for high precision image-guided radiotherapy. Int J Radiat Oncol Biol Phys. 2005;63:975–84.
Grills IS, Hugo G, Kestin LL, Galerani AP, Chao KK, Wloch J, et al. Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy. Int J Radiat Oncol Biol Phys. 2008;70:1045–56.
Sidky EY, Kao C-M, Pan X. Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT. J Xray Sci Technol. 2006;14:119–39.
Sidky EY, Pan X. Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization. Phys Med Biol. 2008;53:4777–807. https://doi.org/10.1088/0031-9155/53/17/021.
Bian J, Siewerdsen JH, Han X, Sidky EY, Prince JL, Pelizzari CA, et al. Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT. Phys Med Biol. 2010;55:6575–99. https://doi.org/10.1088/0031-9155/55/22/001.
Bian J, Yang K, Boone JM, Han X, Sidky EY, Pan X. Investigation of iterative image reconstruction in low-dose breast CT. Phys Med Biol. 2014;59:2659–85. https://doi.org/10.1088/0031-9155/59/11/2659.
Zhang Z, Han X, Pearson E, Pelizzari C, Sidky EY, Pan X. Artifact reduction in short-scan CBCT by use of optimization-based reconstruction. Phys Med Biol. 2016;61:3387–406. https://doi.org/10.1088/0031-9155/61/9/3387.
Xia D, Langan DA, Solomon SB, Zhang Z, Chen B, Lai H, et al. Optimization-based image reconstruction with artifact reduction in C-arm CBCT. Phys Med Biol. 2016;61:7300–33.
Delaney A, Bresler Y, Sunnyvale C. Globally convergent edge-preserving regularized reconstruction: an application to limited-angle tomography. IEEE Trans Image Process. 1998;7:204–21. https://doi.org/10.1109/83.660997.
Elbakri I, Fessler J. Statistical image reconstruction for polyenergetic X-ray computed tomography. IEEE Trans Med Imaging. 2002;21:89–99.
Pan X, Sidky EY, Vannier M. Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction? Inverse Probl. 2009;25:123009. https://doi.org/10.1088/0266-5611/25/12/123009.
Tang J, Nett BE, Chen G-H. Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms. Phys Med Biol. 2009;54:5781–804. https://doi.org/10.1088/0031-9155/54/19/008.
Stsepankou D, Arns A, Ng S, Zygmanski P, Hesser J. Evaluation of robustness of maximum likelihood cone-beam CT reconstruction with total variation regularization. Phys Med Biol. 2012;57:5955–70. https://doi.org/10.1088/0031-9155/57/19/5955.
Sidky EY, Jørgensen JH, Pan X. Convex optimization problem prototyping for image reconstruction in computed tomography with the Chambolle–Pock algorithm. Phys Med Biol. 2012;57:3065–91. https://doi.org/10.1088/0031-9155/57/10/3065.
Wang AS, Stayman JW, Otake Y, Kleinszig G, Vogt S, Gallia GL, et al. Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction. Phys Med Biol. 2014;59:1005–26. https://doi.org/10.1088/0031-9155/59/4/1005.
Nien H, Fessler JA. Fast splitting-based ordered-subsets X-ray CT Image reconstruction. Proceedings of the third international conference on image form Xray computed tomography. 2014. pp. 291–294. https://web.eecs.umich.edu/~fessler/papers/files/proc/14/web/nien-14-FSBpdf. Accessed 16 Jul 2017.
Han X, Bian J, Eaker DR, Kline TL, Sidky EY, Ritman EL, et al. Algorithm-enabled low-dose micro-CT imaging. IEEE Trans Med Imaging. 2011;30:606–20. https://doi.org/10.1109/TMI.2010.2089695.
Bian J, Wang J, Han X, Sidky EY, Shao L, Pan X. Optimization-based image reconstruction from sparse-view data in offset-detector CBCT. Phys Med Biol. 2012;58:205–30. https://doi.org/10.1088/0031-9155/58/2/205.
Zhang Z, Han X, Kusnoto B, Sidky EY, Pan X. Preliminary evaluation of dental cone-beam CT image reconstruction from reduced projection data by constrained TV-minimization. Proceedings of the third international conference on image form Xray computed tomography. 2014. pp. 299–302. https://www.researchgate.net/publications/312068633_preliminary_Evaluation_of_Dental_Cone-beam_CT_Image_from_Reduced_Projection_Data_by_Constrained-TV_minimization. Accessed 16 Jul 2017.
Kusnoto B, Kaur P, Salem A, Zhang Z, Galang-Boquiren MT, Viana G, et al. Implementation of ultra-low-dose CBCT for routine 2D orthodontic diagnostic radiographs: cephalometric landmark identification and image quality assessment. Semin Orthod. 2015;21:233–47. https://doi.org/10.1053/j.sodo.2015.07.001.
Chambolle A, Pock T. A first-order primal-dual algorithm for convex problems with applications to imaging. J Math Imaging Vis. 2011;40:120–45. https://doi.org/10.1007/s10851-010-0251-1.
Sidky EY, Kraemer DN, Roth EG, Ullberg C, Reiser IS, Pan X. Analysis of iterative region-of interest image reconstruction for x-ray computed tomography. J Med Imaging (Bellingham). 2014;1:031007. https://doi.org/10.1117/1.JMI.1.3.031007.
Sidky EY, Chartrand R, Boone JM, Pan X. Constrained TpV minimization for enhanced exploitation of gradient sparsity: application to CT image reconstruction. IEEE J Trans Eng Health Med. 2014;2:1–18.
Zhang Z, Ye J, Chen B, Perkins AE, Rose S, Sidky EY, et al. Investigation of optimization-based reconstruction with an image-total-variation constraint in PET. Phys Med Biol. 2016;61:6055–84. https://doi.org/10.1088/0031-9155/61/16/6055.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this chapter
Cite this chapter
Galang-Boquiren, M.T.S., Kusnoto, B., Zheng, Z., Pan, X. (2019). Dose Adjustments for Accuracy: Ultralow Dose Radiation 3D CBCT for Dental and Orthodontic Application. In: Kadioglu, O., Currier, G. (eds) Craniofacial 3D Imaging. Springer, Cham. https://doi.org/10.1007/978-3-030-00722-5_5
Download citation
DOI: https://doi.org/10.1007/978-3-030-00722-5_5
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-00721-8
Online ISBN: 978-3-030-00722-5
eBook Packages: MedicineMedicine (R0)