Dose Adjustments for Accuracy: Ultralow Dose Radiation 3D CBCT for Dental and Orthodontic Application

  • Chapter
  • First Online:
Book cover Craniofacial 3D Imaging

Abstract

Cone beam computed tomography (CBCT) is increasingly popular when gathering initial patient imaging records for diagnosis and treatment planning. Although traditional two-dimensional panoramic or cephalometric radiographs can provide sufficient information to perform treatment in most cases, clinicians have become aware of the distortion inherent with these radiographs that can affect angular and linear measurements and, more importantly, tooth location and tooth-bone-jaw relationships.

A problem with CBCT technology is that its routine use poses a health risk as a source of ionizing radiation, especially in orthodontic patients who are mostly growing patients, preadolescent, and adolescent.

But what if there was a way to reduce the radiation dose and still reap the benefits of this technology to better serve our patients? This chapter will discuss dose adjustment methods used in the medical arena and their applications in the dental profession, with special focus on orthodontics.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. American Association of Orthodontists. Statement on the role of CBCT in orthodontics. Creve Coeur, MO: American Association of Orthodontists; 2010. p. 26-10H.

    Google Scholar 

  2. American Dental Association Council on Scientific Affairs. The use of cone beam computed tomography in dentistry: an advisory statement from the American Dental Association Council on Scientific Affairs. J Am Dent Assoc. 2012;143:899–902.

    Article  Google Scholar 

  3. American Academy of Oral and Maxillofacial Radiology. Clinical recommendations regarding use of cone beam computed tomography in orthodontics. Position statement by the American Academy of Oral and Maxillofacial Radiology. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013;116:238–57. https://doi.org/10.1016/j.OOOO.2013.06.002.

    Article  Google Scholar 

  4. Ludlow JB. A manufacturer’s role in reducing the dose of cone beam computed tomography examinations: effect of beam filtration. Dentomaxillofac Radiol. 2011;40:115–22. https://doi.org/10.1259/dmfr/31708191.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  5. Qiu W, Pengpan T, Smith ND, Soleimani M. Evaluating iterative algebraic algorithms in terms of convergence and image quality for cone beam CT. Comput Methods Prog Biomed. 2013;109:313–22. https://doi.org/10.1016/j.cmpb.2012.09.006.

    Article  CAS  Google Scholar 

  6. Park JC, Song B, Kim JS, Park SH, Kim HK, Liu Z, et al. Fast compressed sensing-based CBCT reconstruction using Barzilai–Borwein formulation for application to on-line IGRT. Med Phys. 2012;39:1207–17. https://doi.org/10.1118/1.3679865.

    Article  PubMed  Google Scholar 

  7. Walker L, Enciso R, Mah J. Three-dimensional localization of maxillary canines with cone-beam computed tomography. Am J Orthod Dentofac Orthop. 2005;128:418–23.

    Article  Google Scholar 

  8. Hatcher DC, Miller A, Peck JL, Sameshima GT, Worth P. Mesiodistal root angulation using panoramic and cone beam CT. Angle Orthod. 2007;77:206–13.

    Article  Google Scholar 

  9. Monnerat C, Restle L, Mucha JN. Tomographic mapping of mandibular interradicular spaces for placement of orthodontic mini-implants. Am J Orthod Dentofac Orthop. 2009;135:428–9.

    Article  Google Scholar 

  10. Baik HS, Kim KD, Lee KJ, Park SH, Yu HS. A proposal for a new analysis of craniofacial morphology by 3-dimensional computed tomography. Am J Orthod Dentofac Orthop. 2006;129:600. e23–600. e34.

    Google Scholar 

  11. Nakajima A, Arai Y, Dougherty H Sr, Homme Y, Sameshima GT, Shimizu N. Two- and three-dimensional orthodontic imaging using limited cone beam–computed tomography. Angle Orthod. 2005;75:895–903.

    PubMed  Google Scholar 

  12. Larson BE. Cone-beam computed tomography is the imaging technique of choice for comprehensive orthodontic assessment. Am J Orthod Dentofac Orthop. 2012;141:402–4., 406 passim. https://doi.org/10.1016/j.ajodo.2012.02.009.

    Article  Google Scholar 

  13. Halazonetis DJ. Cone-beam computed tomography is not the imaging technique of choice for comprehensive orthodontic assessment. Am J Orthod Dentofac Orthop. 2012;141:403–5., 407 passim. https://doi.org/10.1016/j.ajodo.2012.02.010.

    Article  Google Scholar 

  14. Wiesent K, Barth K, Navab N, Durlak P, Brunner T, Schuetz T, et al. Enhanced 3-D-reconstruction algorithm for C-arm systems suitable for interventional procedures. IEEE Trans Med Imaging. 2000;19:391–403.

    Article  CAS  Google Scholar 

  15. Lauritsch G, Boese J, Wigström L, Kemeth H, Fahrig R. Towards cardiac C-arm computed tomography. IEEE Trans Med Imaging. 2006;25:922–34.

    Article  Google Scholar 

  16. Wallace MJ, Kuo MD, Glaiberman C, Binkert CA, Orth RC, Soulez G. Three-dimensional C-arm cone-beam CT: applications in the interventional suite. J Vasc Interv Radiol. 2008;19:799–813. https://doi.org/10.1016/j.jvir.2008.02.018.

    Article  PubMed  Google Scholar 

  17. Orth RC, Wallace MJ, Kuo MD. C-arm cone-beam CT: general principles and technical considerations for use in interventional radiology. J Vasc Interv Radiol. 2008;19:814–20. https://doi.org/10.1016/j.jvir.2008.02.002.

    Article  PubMed  Google Scholar 

  18. Grass M, Koppe R, Klotz E, Proksa R, Kuhn M, Aerts H, et al. Three-dimensional reconstruction of high contrast objects using C-arm image intensifier projection data. Comput Med Imaging Graph. 1999;23:311–21.

    Article  CAS  Google Scholar 

  19. Siewerdsen JH, Moseley DJ, Burch S, Bisland SK, Bogaards A, Wilson BC, et al. Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery. Med Phys. 2005;32:241–54.

    Article  CAS  Google Scholar 

  20. Hott JS, Deshmukh VR, Klopfenstein JD, Sonntag VK, Dickman CA, Spetzler RF, et al. Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases. Neurosurgery. 2004;54:1131–7.

    Article  Google Scholar 

  21. De Vos W, Casselman J, Swennen G. Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: a systematic review of the literature. Int J Oral Maxillofac Surg. 2009;38:609–25. https://doi.org/10.1016/j.ijom.2009.02.028.

    Article  Google Scholar 

  22. Jaffray DA, Siewerdsen JH, Wong JW, Martinez AA. Flat-panel cone-beam computed tomography for image-guided radiation therapy. Int J Radiat Oncol Biol Phys. 2002;53:1337–49.

    Article  Google Scholar 

  23. Oldham M, Létourneau D, Watt L, Hugo G, Yan D, Lockman D, et al. Cone-beam-CT guided radiation therapy: a model for on-line application. Radiother Oncol. 2005;75:271–8.

    Article  Google Scholar 

  24. Smitsmans MH, De Bois J, Sonke J-J, Betgen A, Zijp LJ, Jaffray DA, et al. Automatic prostate localization on cone-beam CT scans for high precision image-guided radiotherapy. Int J Radiat Oncol Biol Phys. 2005;63:975–84.

    Article  Google Scholar 

  25. Grills IS, Hugo G, Kestin LL, Galerani AP, Chao KK, Wloch J, et al. Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy. Int J Radiat Oncol Biol Phys. 2008;70:1045–56.

    Article  Google Scholar 

  26. Sidky EY, Kao C-M, Pan X. Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT. J Xray Sci Technol. 2006;14:119–39.

    Google Scholar 

  27. Sidky EY, Pan X. Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization. Phys Med Biol. 2008;53:4777–807. https://doi.org/10.1088/0031-9155/53/17/021.

    Article  PubMed  PubMed Central  Google Scholar 

  28. Bian J, Siewerdsen JH, Han X, Sidky EY, Prince JL, Pelizzari CA, et al. Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT. Phys Med Biol. 2010;55:6575–99. https://doi.org/10.1088/0031-9155/55/22/001.

    Article  PubMed  PubMed Central  Google Scholar 

  29. Bian J, Yang K, Boone JM, Han X, Sidky EY, Pan X. Investigation of iterative image reconstruction in low-dose breast CT. Phys Med Biol. 2014;59:2659–85. https://doi.org/10.1088/0031-9155/59/11/2659.

    Article  PubMed  PubMed Central  Google Scholar 

  30. Zhang Z, Han X, Pearson E, Pelizzari C, Sidky EY, Pan X. Artifact reduction in short-scan CBCT by use of optimization-based reconstruction. Phys Med Biol. 2016;61:3387–406. https://doi.org/10.1088/0031-9155/61/9/3387.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  31. Xia D, Langan DA, Solomon SB, Zhang Z, Chen B, Lai H, et al. Optimization-based image reconstruction with artifact reduction in C-arm CBCT. Phys Med Biol. 2016;61:7300–33.

    Article  Google Scholar 

  32. Delaney A, Bresler Y, Sunnyvale C. Globally convergent edge-preserving regularized reconstruction: an application to limited-angle tomography. IEEE Trans Image Process. 1998;7:204–21. https://doi.org/10.1109/83.660997.

    Article  CAS  PubMed  Google Scholar 

  33. Elbakri I, Fessler J. Statistical image reconstruction for polyenergetic X-ray computed tomography. IEEE Trans Med Imaging. 2002;21:89–99.

    Article  Google Scholar 

  34. Pan X, Sidky EY, Vannier M. Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction? Inverse Probl. 2009;25:123009. https://doi.org/10.1088/0266-5611/25/12/123009.

    Article  Google Scholar 

  35. Tang J, Nett BE, Chen G-H. Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms. Phys Med Biol. 2009;54:5781–804. https://doi.org/10.1088/0031-9155/54/19/008.

    Article  PubMed  PubMed Central  Google Scholar 

  36. Stsepankou D, Arns A, Ng S, Zygmanski P, Hesser J. Evaluation of robustness of maximum likelihood cone-beam CT reconstruction with total variation regularization. Phys Med Biol. 2012;57:5955–70. https://doi.org/10.1088/0031-9155/57/19/5955.

    Article  CAS  PubMed  Google Scholar 

  37. Sidky EY, Jørgensen JH, Pan X. Convex optimization problem prototyping for image reconstruction in computed tomography with the Chambolle–Pock algorithm. Phys Med Biol. 2012;57:3065–91. https://doi.org/10.1088/0031-9155/57/10/3065.

    Article  PubMed  PubMed Central  Google Scholar 

  38. Wang AS, Stayman JW, Otake Y, Kleinszig G, Vogt S, Gallia GL, et al. Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction. Phys Med Biol. 2014;59:1005–26. https://doi.org/10.1088/0031-9155/59/4/1005.

    Article  PubMed  PubMed Central  Google Scholar 

  39. Nien H, Fessler JA. Fast splitting-based ordered-subsets X-ray CT Image reconstruction. Proceedings of the third international conference on image form Xray computed tomography. 2014. pp. 291–294. https://web.eecs.umich.edu/~fessler/papers/files/proc/14/web/nien-14-FSBpdf. Accessed 16 Jul 2017.

  40. Han X, Bian J, Eaker DR, Kline TL, Sidky EY, Ritman EL, et al. Algorithm-enabled low-dose micro-CT imaging. IEEE Trans Med Imaging. 2011;30:606–20. https://doi.org/10.1109/TMI.2010.2089695.

    Article  PubMed  Google Scholar 

  41. Bian J, Wang J, Han X, Sidky EY, Shao L, Pan X. Optimization-based image reconstruction from sparse-view data in offset-detector CBCT. Phys Med Biol. 2012;58:205–30. https://doi.org/10.1088/0031-9155/58/2/205.

    Article  PubMed  PubMed Central  Google Scholar 

  42. Zhang Z, Han X, Kusnoto B, Sidky EY, Pan X. Preliminary evaluation of dental cone-beam CT image reconstruction from reduced projection data by constrained TV-minimization. Proceedings of the third international conference on image form Xray computed tomography. 2014. pp. 299–302. https://www.researchgate.net/publications/312068633_preliminary_Evaluation_of_Dental_Cone-beam_CT_Image_from_Reduced_Projection_Data_by_Constrained-TV_minimization. Accessed 16 Jul 2017.

  43. Kusnoto B, Kaur P, Salem A, Zhang Z, Galang-Boquiren MT, Viana G, et al. Implementation of ultra-low-dose CBCT for routine 2D orthodontic diagnostic radiographs: cephalometric landmark identification and image quality assessment. Semin Orthod. 2015;21:233–47. https://doi.org/10.1053/j.sodo.2015.07.001.

    Article  Google Scholar 

  44. Chambolle A, Pock T. A first-order primal-dual algorithm for convex problems with applications to imaging. J Math Imaging Vis. 2011;40:120–45. https://doi.org/10.1007/s10851-010-0251-1.

    Article  Google Scholar 

  45. Sidky EY, Kraemer DN, Roth EG, Ullberg C, Reiser IS, Pan X. Analysis of iterative region-of interest image reconstruction for x-ray computed tomography. J Med Imaging (Bellingham). 2014;1:031007. https://doi.org/10.1117/1.JMI.1.3.031007.

    Article  Google Scholar 

  46. Sidky EY, Chartrand R, Boone JM, Pan X. Constrained TpV minimization for enhanced exploitation of gradient sparsity: application to CT image reconstruction. IEEE J Trans Eng Health Med. 2014;2:1–18.

    Article  Google Scholar 

  47. Zhang Z, Ye J, Chen B, Perkins AE, Rose S, Sidky EY, et al. Investigation of optimization-based reconstruction with an image-total-variation constraint in PET. Phys Med Biol. 2016;61:6055–84. https://doi.org/10.1088/0031-9155/61/16/6055.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Budi Kusnoto .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Galang-Boquiren, M.T.S., Kusnoto, B., Zheng, Z., Pan, X. (2019). Dose Adjustments for Accuracy: Ultralow Dose Radiation 3D CBCT for Dental and Orthodontic Application. In: Kadioglu, O., Currier, G. (eds) Craniofacial 3D Imaging. Springer, Cham. https://doi.org/10.1007/978-3-030-00722-5_5

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-00722-5_5

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-00721-8

  • Online ISBN: 978-3-030-00722-5

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics