Abstract
The paper presents two noncontact pulse rate measurement techniques from vowel speech signals and Eulerian Video Magnification. The proposed methods use signals those are neither audible nor visible to naked eyes. The signals are recorded and their characteristic plots and spectrum analysis by Short-Time Fourier Transform reveal some peaks from which pulse rate can be calculated. The methods are then compared with the conventional methods where the accuracy differs by only 3.9% for vowel speech and by 0.4% for Eulerian Video Magnification. The Bland–Altman plot for the techniques shows that both are acceptable as they lie between ±1.96 Standard Deviation. The data collected from the methods are processed in MATLAB and also implemented on FPGA using serial communication by RS232.
Keywords
- Biomedical
- Image processing
- Eulerian video magnification
- Vowel speech
- Short-time Fourier transform
- FPGA
- Bland–Altman plot
- RS232
This is a preview of subscription content, access via your institution.
Buying options









References
James AP (2015) Heart rate monitoring using human speech spectral features. Hum-Centric Comput Inf Sci 5(1):33
Mesleh A et al (2012) Heart rate extraction from vowel speech signals. J Comput Sci Technol 27(6):1243–1251
Sukaphat S et al (2016) Heart rate measurement on Android platform. In: 2016 13th international conference on electrical engineering/electronics, computer, telecommunications and information technology (ECTI-CON). IEEE, New York, pp 1–5
He X, Goubran RA, Liu XP (2016) Wrist pulse measurement and analysis using Eulerian video magnification. In: 2016 IEEE EMBS international conference on biomedical and health informatics (BHI). IEEE, New York, pp 1–4
Aubel C, Stotz D, Bölcskei H (2018) A theory of super-resolution from short-time Fourier transform measurements. J Fourier Anal Appl 24(1):45–107
Zhang G (2018) Time-phase amplitude spectra based on a modified short-time Fourier transform. Geophys Prospect 66(1):34–46
He X, Goubran RA, Liu XP (2014) Using Eulerian video magnification framework to measure pulse transit time. In: 2014 IEEE international symposium on medical measurements and applications (MeMeA). IEEE, New York, pp 1–4
Pokharkar S (2015) FPGA based design and implementation of ECG feature extraction. Int J Adv Found Res Sci Eng (IJAFRSE) 1(12)
Altman DG, Bland JM (2017) Assessing agreement between methods of measurement. Clin Chem 63(10):1653–1654
Matsuura N et al (2017) Bland–Altman analysis for method comparisons. Adv Mod Med 354
Ryskaliyev A, Askaruly S, James AP (2016) Speech signal analysis for the estimation of heart rates under different emotional states. In: 2016 International conference on advances in computing, communications and informatics (ICACCI). IEEE, New York
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this paper
Cite this paper
Paul, R., Shandilya, R., Sharma, R.K. (2019). Comparative Study and Analysis of Pulse Rate Measurement by Vowel Speech and EVM. In: Pandian, D., Fernando, X., Baig, Z., Shi, F. (eds) Proceedings of the International Conference on ISMAC in Computational Vision and Bio-Engineering 2018 (ISMAC-CVB). ISMAC 2018. Lecture Notes in Computational Vision and Biomechanics, vol 30. Springer, Cham. https://doi.org/10.1007/978-3-030-00665-5_15
Download citation
DOI: https://doi.org/10.1007/978-3-030-00665-5_15
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-00664-8
Online ISBN: 978-3-030-00665-5
eBook Packages: EngineeringEngineering (R0)