Skip to main content

Non-Contact On-Chip Manipulation of 3-D Microtools and Its Applications

(Magnetically Modified Soft Microactuators for Particle Manipulation)

  • Chapter
Next-Generation Actuators Leading Breakthroughs
  • 1700 Accesses

Abstract

This chapter describes a novel non-contact manipulation system using an on-chip, magnetically driven micro-tool (MMT) rather than conventional biomanipulation by hand, which has a higher risk of contamination and lower success rate and repeatability. MMTs can sort particles individually, and have the unique feature that they can be installed directly in a microchannel (width = 150 µm), unlike conventional cell sorting systems. The drive unit was significantly improved by focusing magnetic field on-chip and reduced the magnetic interaction region. Also, we have investigated an active size controlled droplet generation system by using magnetically driven microtool (MMT). With a lateral motion of the MMT in microchannels, the continuous phase can be pinched off by the movement of MMT to obtain size-controlled droplets actively.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Song JM, Griffin GD, Vo-Dinh T (2003) Application of an integrated microchip system with capillary array electrophoresis to optimization of enzymatic reactions. Analytica Chimica Acta, 487:75–82.

    Article  Google Scholar 

  2. Kaigala GV, Hoang VN, Stickel A., Lauzon J, Manage D, Pilarskib LM and Backhouse CJ (2008) An inexpensive and portable microchip-based platform for integrated RT–PCR and capillary electrophoresis, Analyst, 133:331-338,.

    Article  Google Scholar 

  3. Melamed MR, Lindmo T and Mendelsohn ML (1991) Flow Cytometry and Sorting, second edition, Wiley-Liss, New York, USA.

    Google Scholar 

  4. Fuhr G, Hagedorn R et al (1991) Linear motion of dielectric particles and living cells in microfabricated structures induced by traveling electric fields, Proc. of IEEE Micro Electro Mechanical systems, 259-264.

    Google Scholar 

  5. Arai F, Ichikawa A, Ogawa M, Fukuda T, Horio K and Itoigawa K (2001) High-speed separation systems of randomly suspended single living cells by laser trap and dielectrophoresis, Electrophoresis 22:283-288.

    Article  Google Scholar 

  6. Shirasaki Y et al (2002) A Novel Biomolecule Sorter Using Thermosensitive Hydrogel in Micro Flow System. Proc. of the Micro Total Analysis Systems ( -TAS2002), 925-927.

    Google Scholar 

  7. Ashkin A and Dziedzic JM (1987) Optical trapping and manipulation of viruses and bacteria”, Science, 235:1517.

    Google Scholar 

  8. Pamme N (2006) Magnetism and microfluidics, Lab on a Chip 6:24-38.

    Article  Google Scholar 

  9. Crick FHC and Hughes AFW (1949) The physical properties of cytoplasm-A study by means of the magnetic particle method, Experimental Cell Research 1:37-80.

    Article  Google Scholar 

  10. Abbott JJ, Nagy Z, Beyeler F and Nelson BJ (2007) Robotics in the Small, IEEE Robotics & Automation Magazine, 92-103.

    Google Scholar 

  11. Yamanishi Y, Lin YC and Arai F (2007) Magnetically Modified PDMD Microtools for Micro Particle Manipulation, Proceedings of the 2007 IEEE/RSJ International Conference on Intelligent Robotics and Systems, 753-758.

    Google Scholar 

  12. Yamanishi Y, Lin YC and Arai F (2007) Magnetically Modified PDMS Devices for Active Microfluidic Control, -TAS2007, 883-885.

    Google Scholar 

  13. Yamanishi Y, Sakuma S and Arai F (2007) Magnetically Modified Soft Micro Actuator for Oocyte Manipulation, IEEE International Symposium on Micromechatronics and Human Science (MHS), 442-447.

    Google Scholar 

  14. Yamanishi Y, Sakuma S and Arai F (2008) High-accuracy Polymer-based Magnetically Driven Microtool Production and Application, Journal of Robotics and Mechatronics, 20(2):273-279.

    Google Scholar 

  15. Yamanishi Y, Sakuma S, Onda K, Arai F (2008) Biocompatible Polymeric Magnetically Driven Microtool for Particle Sorting, Journal of Micro - Nano Mechatronics, 4(1):49-57.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 Springer-Verlag London Limited

About this chapter

Cite this chapter

Arai, F., Yamanishi, Y. (2010). Non-Contact On-Chip Manipulation of 3-D Microtools and Its Applications. In: Higuchi, T., Suzumori, K., Tadokoro, S. (eds) Next-Generation Actuators Leading Breakthroughs. Springer, London. https://doi.org/10.1007/978-1-84882-991-6_12

Download citation

  • DOI: https://doi.org/10.1007/978-1-84882-991-6_12

  • Publisher Name: Springer, London

  • Print ISBN: 978-1-84882-990-9

  • Online ISBN: 978-1-84882-991-6

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics