Notes
- 1.
Perutz, MF. Molecular anatomy, physiology, and pathology of hemoglobin. In: Stamatoyannopoulos, G, Nienhuis, AW, et al. (Eds). The Molecular Basis of Blood Disorders, WB Saunders, Philadelphia, 1987
Bunn, HF, Forget, BG. Hemoglobin: Molecular, Genetic and Clinical Aspects. WB Saunders, Philadelphia 1986
- 2.
Stamler, JS, Jia, L, Eu JP, McMahon, TJ, Demchenko, IT, Bonaventura, J, Gernert, K, Piantadosi, CA. Blood flow regulation by S-nitrosohemoglobin in the physiological oxygen gradient. Science 1997; 276:2034–2037
McMahon, TJ, Moon, RE, Luschinger, BP, Carraway, MS, Stone, AE, Stolp, BW, Gow, AJ, Pawloski, JR, Watke, P, Singel, DJ, et al. Nitric oxide in the human respiratory cycle. Nat Med 2002; 8:711–717
- 3.
Perutz, MF. Molecular anatomy, physiology, and pathology of hemoglobin. In: Stamatoyannopoulos, G, Nienhuis, AW, et al. (Eds). The Molecular Basis of Blood Disorders, WB Saunders, Philadelphia, 1987
Bunn, HF, Forget, BG. Hemoglobin: Molecular, Genetic and Clinical Aspects. WB Saunders, Philadelphia, 1986
- 4.
Bohr, C, Hasselbalch, K, Krogh, A. Ueber einen in biologischer Beziehung wichtigen Einfluss. den die Kohlen- sauerespannung des Blutes auf dessen Sauerstoffbinding ubt. Skand Arch Physiol 1904; 16:402
Busch, MR, Mace, JE, Ho, NT, Ho, C. Roles of the beta 146 histidyl residue in the molecular basis of the Bohr effect of hemoglobin: A proton nuclear magnetic resonance study. Biochemistry 1991; 30:1865
Klocke RA. Mechanism and kinetics of the Haldane effect in human erythrocytes. J Appl Physiol 1973; 35:673–681
- 5.
Interpreting Arterial Blood Gases, Canham EM, Beuther DA, PCCU-on line, Chest.
- 6.
Pierson, DJ. Pulse oximetry versus arterial blood gas specimens in long-term oxygen therapy. Lung 1990; 168 Suppl:782
Inman, KJ, Sibbald, WJ, Rutledge, FS. Does implementing pulse oximetry in a critical care unit result in substantial arterial blood gas savings? Chest 1993; 104: 543
- 7.
Bongard, F, Sue, D. Pulse oximetry and capnography in intensive and transitional care units. West J Med 1992; 156:57
Greene, GE, Hassel, KT, Mahutte, CK. Comparison of arterial blood gas with continuous intraarterial and transcutaneous PO2 sensor in adult critically ill parients. Crit Care Med 1987; 15:491
- 8.
Comroe, JH Jr, Botelho, S. The unreliability of cyanosis in the recognition of arterial hpoxemia. Am J Med Sci 1947; 214:1
Martin, L, Khalil, H. How much reduced hemoglobin is necessary to generate central cyanosis? Chest 1990; 97:182
Neff, TA. Routine oximetry: A fifth vital sign? Chest 1988; 94:227
- 9.
Interpreting Arterial Blood Gases, Canham EM, Beuther DA, PCCU-on line, Chest.
- 10.
Hanning, CD, Alexander-Williams, JM. Pulse oximetry: A practical review. BMJ 1995
- 11.
Mendelson, Y. Pulse oximetry: Theory and applications for noninvasive monitoring. Clin Chem 1992; 38:1601
- 12.
Mendelson, Y. Pulse oximetry: Theory and applications for noninvasive monitoring. Clin Chem 1992; 38:1601
- 13.
Tallon, RW. Oximetry: state-of-the-art. Nurs Manage 1996; 27:43
- 14.
Stoneham, MD. Uses and limitations of pulse oximetry. Br J Hosp Med 1995; 54:35
Ralston, AC, Webb, RK, Runciman, WB. Potential errors in pulse oximetry. Anaesthesia 1991; 46:291
- 15.
Schnapp, LM, Cohen, NH. Pulse oximetry: Uses and abuses. Chest 1990; 98:1244
- 16.
Ralston, AC, Webb, RK, Runciman, WB. Potential errors in pulse oximetry. III: Effects of interference, dyes, dyshaemoglobins and other pigments. Anaesthesia 1991; 46:291
Veyckemans, F, Baele, P, Guillaume, JE, et al. Hyperbilirubinemia does not interfere with hemoglobin saturation measured by pulse oximetry. Anesthesiology 1989; 70:118
Zeballos, RJ, Weisman, IM. Reliability of noninvasive oximetry in black subjects during exercise and hypoxia. Am Rev Resp Dis 1991; 144:1240
Brand, TM, Brand, ME, Jay, GD. Enamel nail polish does not interfere with pulse oximetry. J Clin Monit Comput 2002; 17:93
- 17.
Eisenkraft, JI, Pulse oximeter desaturation due to methemoglobinemia. Anesthesiology 1988; 68:279
Ernst, A, Zibrak, JD. Carbon monoxide poisoning. New Engl J Med 1998; 339:1603–1608
Ortiz, FO, Aldrich, TK, Nagel, RL, Benjamin, LJ. Accuracy of pulse oximetry in sickle cell disease. Am J Respir Crit Care Med 1999; 159:447
- 18.
Wright, RO, Lewander, WJ, Woolf, AD. Methemoglobinemia: etiology, pharmacology, and clinical management. Ann Emerg Med 1999; 34:646−656
Curry S. Methemoglobinemia. Ann Emerg Med 1982; 11:214–221
- 19.
Curry, S. Methemoglobinemia. Ann Emerg Med 1982; 11:214–221
Jaffe, ER. Enzymopenic hereditary methemoglobinemia: a clinical/ biochemicalclassification. Blood Cells 1986; 12:81–90
Prchal, JT. Diagnosis and treatment of methemoglobinemia, Uptodate.com
- 20.
Park, CM, Nagel, RL. Sulfhemoglobinemia. N Engl J Med 1984; 310:1579–1584
- 21.
Weaver, LK. Carbon monoxide poisoning. Crit Care Clin 1999; 15:297.
Caughey, WS. Carbon monoxide bonding in hemeproteins. Ann N Y Acad Sci 1970; 174:148.
- 22.
Greenberg, AG, Terlizzi, L, Peskin, G. Oxyhemoglobin affinity in acute pancreatitis. J Surg Res 22: 561–565, 1977
- 23.
Eisenkraft, JB. Pulse oximeter desaturation due to methaemoglobinemia. Anaesthesiology 1988; 68:279–282
Oesenberg, B. Pulse oximetry in methaemoglobinemia. Anaesthesia 1990;45:56
Mokhlesi, B, Leiken, JB, Murray, P, Corbridge, TC. Adult Toxicology in Critical Care, Part I: General Approach to the Intoxicated Patient. (Chest 2003; 123:577–592
- 24.
Gehring, H, Hornberger, C, Matz, H, et al. The effects of motion artifact and low perfusion on the performance of a new generation of pulse oximeters in volunteers undergoing hypoxemia. Respir Care 2002; 47:48
Fluck, RR Jr, Schroeder, C, Frani, G, et al. Does ambient light affect the accuracy of pulse oximetry? Respir Care 2003; 48:677
Ralston, AC, Webb, RK, Runciman, WB. Potential errors in pulse oximetry. Anaesthesia 1991; 46:291
Van de, Louw A, Cracco, C, Cerf, C, et al. Accuracy of pulse oximetry in the intensive care unit. Intensive Care Med 2001; 27:1606
- 25.
Gehring, H, Hornberger, C, Matz, H, et al. The effects of motion artifact and low perfusion on the performance of a new generation of pulse oximeters in volunteers undergoing hypoxemia. Respir Care 2002; 47:48
Lee, WW, Mayberry, K, Crapo, R, Jensen, RL. The accuracy of pulse oximetry in the emergency department. Am J Emerg Med 2000; 18:427
- 26.
Canham, EM. Interpretation of arterial blood gases. In: Parsons, PE, Weiner-Kronish, JP, eds. Critical care secrets. 3rd ed. Philadelphia, Hanley and Belfus, Inc, 21–24, 2003
- 27.
Stock, MC. Capnogrophy for adults. Crit Care Clinics 1995; 11:219
- 28.
Moon, RE, Camporesi, EM. Respiratory monitoring. In: RD Miller, ed. Miller’s anesthesia. 6th ed. Philadelphia, PA: Elsevier/Churchill Livingstone, 2005
Kalenda, Z. Mastering infrared Capnography. The Netherlands, Kerckbosch-Ziest 1989
Carbon dioxide monitors. Health Devices 1986; 15:255–85
- 29.
Nunn, JF, Hill, DW. Respiratory dead space and arterial to end-tidal CO2 tension difference in anesthetized man. J Appl Physiol 1960; 15:383–9
Fletcher, R, Jonson, B. Deadspace and the single breath test for carbon dioxide during anaesthesia and artificial ventilation. Br J Anaeasth 1984; 56:109–119
Shankar, KB, Moseley, H, Kumar, Y, Vemula, V. Arterial to end-tidal carbon dioxide tension difference during cesarean section anaesthesia. Anaesthesia 1986; 41:698–702
- 30.
(Modified from: Bhavani Shankar. Factors influencing PetCO2; March 2007: Welcome to capnography.com)
Bhavani, S. K, Moseley, H, Kumar, AY, Delph, Y. Capnometry and anaesthesia. Review article. Canadian J Anaesth 1992; 39:6:617–632
- 31.
Phan, CQ, Tremper, KK, Lee, SE, Barker, SJ. Noninvasive monitoring of carbon dioxide: A comparison of the partial pressure of transcutaneous and end-tidal carbon dioxide with the partial pressure of arterial carbon dioxide. J Clin Monit 1987; 3:149–54
- 32.
Bhavani, S K, Mosely, H, Kumar, AY, Delph, Y. Capnometry and anaesthesia. Canadian J Anaesth 1992; 39:6:617–632
Criner, GJ, D’Alonzo, GE. Pulmonary Pathophysiology, Blackwell 1999
- 33.
Criner, GJ, D’Alonzo, GE. Pulmonary Pathophysiology, Blackwell, 1999
- 34.
Moorthy, SS, Losasso, AM, Wilcox, J. End-tidal PCo2 greater than PaCO2. Chest 1984; 12:534
- 35.
Isserles, S, Breen, PH. Can changes in end-tidal PCO2 measure changes in cardiac output ? Anest h Anag\lg 1991; 73:808
Shibutani, K, Shirasaki, S, Braaz, T, et al. Changes in cardiac output affect PetCO2, CO2 transport, and O2 uptake during unsteady state in humans. J Clin Monit 1992; 8:175–176
- 36.
Grmec, S, Lah, K, Tusek-Bunc, K. Difference in end-tidal CO2 between asphyxia cardiac arrest and ventricular fibrillation/pulseless ventricular tachycardia cardiac arrest in the prehospital setting. Crit Care 2003; 7:R139–R144
- 37.
Falk, JL, Rackow, ED, Weil, MH, “End-tidal carbon dioxide concentration during cardiopulmonary resuscitation.” N Engl J Med 1988; 318(10):607–611
Grmec, S, Klemen, P. Does the end-tidal carbon dioxide (ETCO2) concentration have prognostic value during out-of-hospital cardiac arrest? J Emerg Med 2001; 8:263–269
Callaham, M , Barton, C. Prediction of out come of cardiopulmonary resuscitation from end-tidal carbon dioxide concentration. Crit Care Med 1990; 18:358
Sanders, AB, Kern, KB, Otto, CW, et al. End-tidal carbon dioxide monitoring during cardiopulmonary resuscitation: a prognostic indicator for survival. JAMA 1989; 262:1347
- 38.
Bhavani Shankar Kodali. 2007. Welcome to Capnography.com
- 39.
Birmingham, PK, Cheney, FW, Ward, RJ. Esophageal intubation: a review of detection techniques. Anesth Analg 1986; 65:886–891
Linlo, K, Paloheimo, M, Tammisto, T. Capnography for detection of accidental oesophageal intubation. Acta Anaesthesiol Sand 1983; 27:199–202
‘O’ Flaherty, D, Adams, AP. The end-tidal carbon dioxide detector. Assessment of new method to distinguish oesophageal from tracheal intubation. Anaesthesia 1990; 45:653–655
- 40.
Bhavani Shankar Kodali 2007.
Welcome to Capnography.com
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 2009 Springer-Verlag London Limited
About this chapter
Cite this chapter
Hasan, A. (2009). The Noninvasive Monitoring of Blood Gases. In: Handbook of Blood Gas/Acid–Base Interpretation. Springer, London. https://doi.org/10.1007/978-1-84800-334-7_3
Download citation
DOI: https://doi.org/10.1007/978-1-84800-334-7_3
Publisher Name: Springer, London
Print ISBN: 978-1-84800-333-0
Online ISBN: 978-1-84800-334-7
eBook Packages: MedicineMedicine (R0)