Skip to main content

Oxygen Saturation Measurements in Acute Heart Failure Syndrome

  • Chapter
Acute Heart Failure

Abstract

The primary physiologic task of the cardiovascular system is to deliver enough oxygen (O2) to meet the metabolic demands of the body. The monitoring of venous O2 saturation measurements (venous oximetry) seems to be more sensible to hemodynamic changes than the simple monitoring of cardiac output in patients with acute heart failure. Indeed, a drop in mixed venous oxygen saturation is a marker not only of decreased cardiac output but also of decreased hemoglobin concentration, impaired arterial oxygenation, and increased tissue oxygen demand. Monitoring venous oxygen saturation is increasingly used as a clinical marker of systemic oxygen utilization in critically ill patients, particularly those with hemodynamic alteration (1,2).

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 139.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 179.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 249.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Rivers E, Nguyen B, Havstad S, et al. Early goaldirected therapy in the treatment of severe sepsis and septic shock. N Engl J Med 2001;345:1368–77.

    Article  CAS  PubMed  Google Scholar 

  2. Reinhart K, Kuhn HJ, Hartog C, Bredle DL. Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill. Intensive Care Med 2004;30:1572–8.

    Article  PubMed  Google Scholar 

  3. Dueck MH, Klimek M, Appenrodt S et al. Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions. Anesthesiology 2005;103:249–57.

    Article  PubMed  Google Scholar 

  4. Gawlinski A. Can measurement of mixed venous oxygen saturation replace measurement of cardiac output in patients with advanced heart failure? Am J Crit Care 1998;7:374–80; quiz 81–2.

    CAS  PubMed  Google Scholar 

  5. Sumimoto T, Takayama Y, Iwasaka T et al. Mixed venous oxygen saturation as a guide to tissue oxygenation and prognosis in patients with acute myocardial infarction. Am Heart J 1991;122:27–33.

    Article  CAS  PubMed  Google Scholar 

  6. Bloos F, Reinhart K. Venous oximetry. Intensive Care Med 2005;31:911–3.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer-Verlag London Limited

About this chapter

Cite this chapter

Gayat, E., Mebazaa, A., de La Garanderie, D.P. (2008). Oxygen Saturation Measurements in Acute Heart Failure Syndrome. In: Mebazaa, A., Gheorghiade, M., Zannad, F.M., Parrillo, J.E. (eds) Acute Heart Failure. Springer, London. https://doi.org/10.1007/978-1-84628-782-4_37

Download citation

  • DOI: https://doi.org/10.1007/978-1-84628-782-4_37

  • Publisher Name: Springer, London

  • Print ISBN: 978-1-84628-781-7

  • Online ISBN: 978-1-84628-782-4

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics