Abstract
The primary physiologic task of the cardiovascular system is to deliver enough oxygen (O2) to meet the metabolic demands of the body. The monitoring of venous O2 saturation measurements (venous oximetry) seems to be more sensible to hemodynamic changes than the simple monitoring of cardiac output in patients with acute heart failure. Indeed, a drop in mixed venous oxygen saturation is a marker not only of decreased cardiac output but also of decreased hemoglobin concentration, impaired arterial oxygenation, and increased tissue oxygen demand. Monitoring venous oxygen saturation is increasingly used as a clinical marker of systemic oxygen utilization in critically ill patients, particularly those with hemodynamic alteration (1,2).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Rivers E, Nguyen B, Havstad S, et al. Early goaldirected therapy in the treatment of severe sepsis and septic shock. N Engl J Med 2001;345:1368–77.
Reinhart K, Kuhn HJ, Hartog C, Bredle DL. Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill. Intensive Care Med 2004;30:1572–8.
Dueck MH, Klimek M, Appenrodt S et al. Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions. Anesthesiology 2005;103:249–57.
Gawlinski A. Can measurement of mixed venous oxygen saturation replace measurement of cardiac output in patients with advanced heart failure? Am J Crit Care 1998;7:374–80; quiz 81–2.
Sumimoto T, Takayama Y, Iwasaka T et al. Mixed venous oxygen saturation as a guide to tissue oxygenation and prognosis in patients with acute myocardial infarction. Am Heart J 1991;122:27–33.
Bloos F, Reinhart K. Venous oximetry. Intensive Care Med 2005;31:911–3.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2008 Springer-Verlag London Limited
About this chapter
Cite this chapter
Gayat, E., Mebazaa, A., de La Garanderie, D.P. (2008). Oxygen Saturation Measurements in Acute Heart Failure Syndrome. In: Mebazaa, A., Gheorghiade, M., Zannad, F.M., Parrillo, J.E. (eds) Acute Heart Failure. Springer, London. https://doi.org/10.1007/978-1-84628-782-4_37
Download citation
DOI: https://doi.org/10.1007/978-1-84628-782-4_37
Publisher Name: Springer, London
Print ISBN: 978-1-84628-781-7
Online ISBN: 978-1-84628-782-4
eBook Packages: MedicineMedicine (R0)