Abstract
Different integrated systems with a bi-enzymatic biosensor, working with two different methods for ethanol detection—flow injection analysis (FIA) or sequential injection analysis (SIA)—were developed and applied for ethanol extracted from gasohol mixtures, as well as for samples of alcoholic beverages and fermentation medium. A detection range of 0.05–1.5 g ethanol/l, with a correlation coefficient of 0.9909, has been reached when using FIA system, working with only one microreactor packed with immobilized alcohol oxidase and injecting free horseradish peroxidase. When using both enzymes, immobilized separately in two microreactors, the detection ranges obtained varied from 0.001 to 0.066 g ethanol/l, without on-line dilution to 0.010–0.047 g ethanol/l when a 1:7,000 dilution ratio was employed, reaching correlation coefficients of 0.9897 and 0.9992, respectively. For the integrated biosensor SIA system with the stop-flow technique, the linear range was 0.005–0.04 g/l, with a correlation coefficient of 0.9922.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Patel, P. D. (2002). Trends in Analytical Chemistry, 21, 96–115.
Taniai, T., Sukurragawa, A., & Okitani, T. (2001). Journal of Association of Official Analytical Chemists International, 84(5), 1475–1483.
Alhadeff, E. M., Salgado, M. A., Pereira, N., Jr., & Valdman, B. (2004). Applied Biochemistry and Biotechnology, 113, 125–136.
Alhadeff, E. M., Salgado, M. A., Pereira, N., Jr., & Valdman, B. (2005). Applied Biochemistry and Biotechnology, 121, 361–372.
van Staden, J. F., & Stefan, R. I. (2004). Talanta, 64, 1109–1113.
Surribas, A., Cos, O., Montesinos, J. L., & Valero, F. (2003). Biotechnology Letters, 25, 1795–1800.
Lapa, R. A. S., Lima, J. L. F. C., & Pinto, I. V. O. S. (2003). Food Chemistry, 81, 141–146.
Masini, J. C., Rigobello-Masini, M., Salatino, A., & Aidar, E. (2001). Latin American Applied Research, 31, 463–468.
Niculescu, M., Erichsen, T., Sukharev, V., Kereny, Z., Csregi, E., & Schuhmann, W. (2002). Analytica Chimica Acta, 463, 39–51.
Segundo, M. A., & Rangel, A. O. S. S. (2002). Analytica Chimica Acta, 458, 131–138.
Coi, M. M. F. (2004). Microchemical Acta, 148, 107–132.
Alhadeff, E. M., Salgado, M. A., Cos, O., Pereira, N., Jr., Valero, F., & Valdman, B. (2007). Applied Biochemistry and Biotechnology, 136–140, 17–26.
Salgado, A. M., Folly, R. O. M., Valdman, B., Cós, O., & Valero, F. (2000). Biotechnology Letters, 22, 327–330.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2008 Humana Press Inc.
About this paper
Cite this paper
Alhadeff, E.M., Salgado, A.M., Cós, O., Pereira, N., Valero, F., Valdman, B. (2008). Integrated Biosensor Systems for Ethanol Analysis. In: Adney, W.S., McMillan, J.D., Mielenz, J., Klasson, K.T. (eds) Biotechnology for Fuels and Chemicals. ABAB Symposium. Humana Press. https://doi.org/10.1007/978-1-60327-526-2_26
Download citation
DOI: https://doi.org/10.1007/978-1-60327-526-2_26
Received:
Accepted:
Published:
Publisher Name: Humana Press
Print ISBN: 978-1-60327-525-5
Online ISBN: 978-1-60327-526-2
eBook Packages: Chemistry and Materials ScienceChemistry and Material Science (R0)