Abstract
Ten years after the introduction of the Scott three-piece inflatable penile prosthesis in 1973 (American Medical Systems, Minnetonka, MN) (1), Mentor Corporation introduced their first three-piece inflatable penile prosthesis, the Mentor IPP (Surgitek, Racine, WI) (2). This device provided an alternative for improving the mechanical reliability of the three-piece inflatable penile prosthesis, which had been reported to be as high as 42% in some series (3). The most important advance that Mentor brought to the field of penile prosthetics was the introduction of a new material, known as Bioflex. Biofelx is an aromatic polyether urea urethane elastomer that provided a tensile strength seven times higher than that of silicone without sacrificing biocompatibility and hemocompatibility (4–6). The physical characteristics of this material, virtually eliminated cylinder failures as a result of aneurysms or wear-induced abrasion, and provided the widest inflatable cylinder girth expansion available.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Scott FB, Bradley WE, Timm GW (1973) Management of erectile dysfunction: use of implantable inflatable prosthesis. Urology 2:80.
Merrill DC (1983) Mentor Inflatable penile prosthesis. Urology 22:504.
Scott FB, Byrd GJ, Karacan I, Olsson P, Beutler LE, Attia SL (1979) Erectile impotence treated with an implantable, inflatable prosthesis. JAMA 241:2609.
Pescatori ES, Goldstein I (1993) Intraluminal device pressures in 3-piece inflatable penile prosthesis: the “pathophysiology” of mechanical malfunction. J Urol 149:295–300.
Hackler RH (1986) Mentor inflatable penile prosthesis: a reliable device. Urology 28:489.
Whalen RK, Merrill DC (1991) Patient satisfaction with Mentor inflatable penile prosthesis. Urology 37:531.
Brooks MB (1988) 42 months experience with Mentor inflatable penile prosthesis. J Urol 139:48.
Merrill DC (1988) Clinical experience with the Mentor inflatable penile prosthesis in 301 patients. J Urol 140:1424.
Wilson SK, Cleves MA, Delk JR (1999) Comparison of the mechanical reliability of Original and enhanced mentor alpha I penile prosthesis. J Urol 162:715–718.
Steinkohl WB, Leach GE (1991) Mechanical complications associated with Mentor inflatable penile prosthesis. Urology 38:32.
Kabalin JN, Kessler R (1988) Five-year follow–up of the Scott inflatable penile prosthesis and comparison with semirigid penile prosthesis. J Urol 140:1428.
Earle CM, Watters GR, Tulloch AGS, Wisniewski ZS, Lord DJ, Keogh EJ (1989) Complications associated with penile implants used to treat impotence. Aust New Zeal J Surg 59:959.
Montague DK (1990) Penile prosthesis implantation: special considerations. Int J Impot Res, supp 1, 2:3.
Woodworth BE, Carson CC, Webster GD (1991) Inflatable penile prosthesis: effect of device modification on functional longevity. Urology 38:533.
Goldstein I, Geffin M, and the Mentor Lock-Out Valve study Group. Prevention of auto-inflation in the Mentor Alpha-1 three piece inflatable penile prosthesis: preliminary results of the Lock-Out Valve Study. 1999 AUA Meeting.
Wilson SK, Delk JR, Van Buren, Dhabuwala CB. Early results with new Lockout Valve to prevent auto inflation of Mentor Alpha 1 penile prosthesis. 1999 AUA Meeting.
Geffin M, LaSalle M, Patel R, Krane RJ, Goldstein I. Clinical outcome of Alpha-1 three piece inflatable penile prosthesis insertion in patients with bilateral severe corporal fibrosis. 1998 AUA Meeting.
Hakim LS, Pham H. Initial clinical experience with the Mentor alpha-one narrow base inflatable penile prosthesis: an effective option for the management of severe corporal fibrosis. 1999 AUA Meeting.
Merril DC (1989) Mentro inflatable penile prosthesis. Urol Clin North Am 16:51–66.
Furlow WL, Motley RC (1988) The inflatable penile prosthesis: clinical experience with a new controlled expansion cylinder. J Urol 139:945–946.
Goldstein I, Newman L, Baum N, Brooks M, Chaikin L, Goldberg K, et al. (1997) Safety and efficacy outcome of Mentor Alpha-1 inflatable penile prosthesis implantation for impotence treatment. J Urol 157(3):833–839.
Goldstein I, Bertero E, Kaufman JM. WittenFR, Hubbard JG, Fitch WP, et al. (1993) Early experience with the first pre-connected 3-piece inflatable penile prosthesis: The Mentor Alpha-1. J Urol 150:1814–1818.
Randrup E, Wilson S, Mobley D, Suarez G, Mekras G, Baum N (1993) Clinical experience with Mentor Alpha I inflatable penile prosthesis. Urology 42(3):305–308.
Garber BB (1996) Inflatable penile prosthesis: results of 150 cases. Br J Urol 78(6):933–935.
Carson CC, Mulkahy JJ, Govier FE, and the AMS 700 Cs study group (2000) Efficacy, safety and patient satisfaction outcomes of the AMS 700CX inflatable prosthesis: results of a long-term multicenter study. J Urol 164:376–380.
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2002 Springer Science+Business Media New York
About this chapter
Cite this chapter
Munarriz, R.M., Goldstein, I. (2002). Experience with the Mentor α-1. In: Carson, C.C. (eds) Urologic Prostheses. Current Clinical Urology. Humana Press, Totowa, NJ. https://doi.org/10.1007/978-1-59259-096-4_12
Download citation
DOI: https://doi.org/10.1007/978-1-59259-096-4_12
Publisher Name: Humana Press, Totowa, NJ
Print ISBN: 978-1-61737-242-1
Online ISBN: 978-1-59259-096-4
eBook Packages: Springer Book Archive