Abstract
The tNIRS-1, a new clinical tissue oximeter using NIR time-resolved spectroscopy (TRS), has been developed. The tNIRS-1 measures oxygenated, deoxygenated and total hemoglobin and oxygen saturation in living tissues. Two-channel TRS measurements are obtained using pulsed laser diodes (LD) at three wavelengths, multi-pixel photon counters (MPPC) for light detection, and time-to-digital converters (TDC) for time-of-flight photon measurements. Incorporating advanced semiconductor devices helped to make the design of this small-size, low-cost and low-power TRS instrument possible. In order to evaluate the correctness and reproducibility of measurement data obtained with the tNIRS-1, a study using blood phantoms and healthy volunteers was conducted to compare data obtained from a conventional SRS device and data from an earlier TRS system designed for research purposes. The results of the study confirmed the correctness and reproducibility of measurement data obtained with the tNIRS-1. Clinical evaluations conducted in several hospitals demonstrated a high level of usability in clinical situations and confirmed the efficacy of measurement data obtained with the tNIRS-1.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Jobsis FF (1977) Non-invasive infrared monitoring of cerebral myocardial oxygen sufficiency and circulatory parameters. Science 198:1264–1267
Cope M, Delpy DT (1988) A system for long-term measurement of cerebral blood and tissue oxygenation in newborn infants by near-infrared transillumination. Med Biol Eng Comput 26:289–294
Matcher SJ, Kirkpatrick P, Nahid M et al (1993) Absolute quantification methods in tissue near infrared spectroscopy. Proc SPIE 2389:486–495
Miwa M, Ueda Y, Chance B (1995) Development of time resolved spectroscopy system for quantitative non-invasive tissue measurement. Proc SPIE 2389:142–149
Suzuki S, Takasaki S, Ozaki T et al (1999) A tissue oxygenation monitor using NIR spatially resolved spectroscopy. Proc SPIE 3597:582–592
Roberts KW, Crnkowic AP, Linneman LJ (1998) Near infrared spectroscopy detects critical cerebral hypoxia during carotid endarterectomy in awake patients. Anesthesiology 89:A934
Ohmae E, Oda M, Suzuki T et al (2007) Clinical evaluation of time-resolved spectroscopy by measuring cerebral hemodynamics during cardiopulmonary bypass surgery. J Biomed Opt 12:062112
Patterson MS, Chance B, Wilson BC (1989) Time resolved reflectance and transmittance for the noninvasive measurement of tissue optical properties. Appl Opt 28:2331–2336
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer Science+Business Media, New York
About this paper
Cite this paper
Fujisaka, Si. et al. (2016). A Clinical Tissue Oximeter Using NIR Time-Resolved Spectroscopy. In: Elwell, C.E., Leung, T.S., Harrison, D.K. (eds) Oxygen Transport to Tissue XXXVII. Advances in Experimental Medicine and Biology, vol 876. Springer, New York, NY. https://doi.org/10.1007/978-1-4939-3023-4_54
Download citation
DOI: https://doi.org/10.1007/978-1-4939-3023-4_54
Publisher Name: Springer, New York, NY
Print ISBN: 978-1-4939-3022-7
Online ISBN: 978-1-4939-3023-4
eBook Packages: Biomedical and Life SciencesBiomedical and Life Sciences (R0)