The determination of the intraocular pressure by means of instruments is still a developing science. Several physical properties and mechanisms affect this measure due to the corneal shape and its rigidity. Experimental and analytical researches are tools to improve indirect technologies (tonometric devices) for this relevant quantity for ophthalmologic diagnosis. In this chapter the applanation contact tonometry is the main subject (biomechanical modeling, computational modeling, and calibration equations); nevertheless, new tonometric devices tend to avoid contact to diminish influence of probe shape in the contact procedure and also pain in the patient.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
R. Sampaolesi, Glaucoma (Editorial Médica Panamericana S.A., Buenos Aires, 1974)
J.E. Hall, Guyton and Hall Textbook of Medical Physiology (Saunders, Enhanced E-Book, 2010)
C. Kniestedt, O. Punjabi, S. Lin, R.L. Stamper, Tonometry through the ages. Surv. Ophthalmol. 53(6), 568–591 (2008)
A. Arciniegas, L.E. Amaya, Mechanical behavior of the Sclera. Ophthalmologica 193(1–2), 45–55 (1986)
P.-A. Tonnu, T. Ho, T. Newson, A. El Sheikh, K. Sharma, E. White et al., The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Br. J. Ophthalmol. 89(7), 851–854 (2005)
A. Kotecha, A. Elsheikh, C.R. Roberts, H. Zhu, D.F. Garway-Heath, Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer. Invest. Ophthalmol. Vis. Sci. 47(12), 5337–5347 (2006)
A. Elsheikh, D. Wang, M. Brown, P. Rama, M. Campanelli, D. Pye, Assessment of corneal biomechanical properties and their variation with age. Curr. Eye Res. 32(1), 11–19 (2007)
A. Elsheikh, D. Wang, P. Rama, M. Campanelli, D. Garway-Heath, Experimental assessment of human corneal hysteresis. Curr. Eye Res. 33(3), 205–213 (2008)
T. Kida, J.H.K. Liu, R.N. Weinreb, Effects of aging on corneal biomechanical properties and their impact on 24-hour measurement of intraocular pressure. Am. J. Ophthalmol. 146(4), 567–572.e1 (2008)
T. Gosho, K. Yamada, N. Yamasaki, M. Higashimori, J. Takenaka, Y. Kiuchi et al., Is cornea compliant with respect to age? in World Congr. Med. Phys. Biomed. Eng. Sept. 7–12 2009 Munich Ger, ed. by O. Dössel, W. Schlegel (Springer, Berlin, 2009), pp. 223–226
A. Elsheikh, B. Geraghty, P. Rama, M. Campanelli, K.M. Meek, Characterization of age-related variation in corneal biomechanical properties. J. R. Soc. Interface 7(51), 1475–1485 (2010)
N. Ehlers, T. Bramsen, S. Sperling, Applanation tonometry and central corneal thickness. Acta Ophthalmol. (Copenh) 53(1), 34–43 (1975)
G. Orssengo, D. Pye, Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo. Bull. Math. Biol. 61(3), 551–572 (1999)
M.E. Iliev, A. Meyenberg, E. Buerki, G. Shafranov, M.B. Shields, Novel pressure-to-cornea index in glaucoma. Br. J. Ophthalmol. 91(10), 1364–1368 (2007)
E. Chihara, Assessment of true intraocular pressure: the gap between theory and practical data. Surv. Ophthalmol. 53(3), 203–218 (2008)
T.H. Kwon, J. Ghaboussi, D.A. Pecknold, Y.M.A. Hashash, Effect of cornea material stiffness on measured intraocular pressure. J. Biomech. 41(8), 1707–1713 (2008)
A. Elsheikh, D. Alhasso, P. Gunvant, D. Garway-Heath, Multiparameter correction equation for Goldmann applanation tonometry. Optom. Vis. Sci. 88(1), E102–E112 (2011)
A.F. Guzmán, A. Arciniegas Castilla, F.A. Guarnieri, R.F. Ramírez, Intraocular pressure: Goldmann tonometry, computational model, and calibration equation. J. Glaucoma 22(1), 10–14 (2013)
C.C. Mow, A theoretical model of the cornea for use in studies of tonometry. Bull. Math. Biophys. 30(3), 437–453 (1968)
M. Whitacre, M. Emig, K. Hassanein, The effect of Perkins, Tono-Pen, and Schiotz tonometry on intraocular pressure. Am J. Ophthalmol. 111(1), 59–64 (1991)
M.M. Whitacre, R. Stein, Sources of error with use of Goldmann-type tonometers. Surv. Ophthalmol. 38(1), 1–30 (1993)
M. Whitacre, R. Stein, K. Hassanein, The effect of corneal thickness on applanation tonometry. Am J. Ophthalmol. 115(5), 592–596 (1993)
N. Feltgen, D. Leifert, J. Funk, Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings. Br. J. Ophthalmol. 85(1), 85–87 (2001)
J. Liu, C.J. Roberts, Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J. Cataract Refract. Surg. 31(1), 146–155 (2005)
A. Kotecha, E.T. White, J.M. Shewry, D.F. Garway-Heath, The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry. Br. J. Ophthalmol. 89(12), 1572–1575 (2005)
A.T. Broman, N.G. Congdon, K. Bandeen-Roche, H.A. Quigley, Influence of corneal structure, corneal responsiveness, and other ocular parameters on tonometric measurement of intraocular pressure. J. Glaucoma 16(7), 581–588 (2007)
K.E. Hamilton, D.C. Pye, Young’s modulus in normal corneas and the effect on applanation tonometry. Optom. Vis. Sci. 85(6), 445–450 (2008). doi:10.1097/OPX.0b013e3181783a70
H.H. Mark, Armand Imbert, Adolf Fick, and their tonometry law. Eye 26(1), 13–16 (2012)
H. Goldmann, T. Schmidt, Über Applanationstonometrie. Ophthalmologica 134(4), 221–242 (1957)
H. Goldmann, T. Schmidt, Weiterer Beitrag zur Applanationstonometrie. Ophthalmologica 141(6), 441–456 (1961)
H. Goldmann, Un nouveau tonometre d’applanation. Bull. Soc. Ophtalmol. Fr 67, 474–478 (1955)
G.C. Stuckey, Application of physical principles in the development of tonometry. Clin. Exp. Ophthalmol. 32(6), 633–636 (2004)
J.I. Barraquer, Cirugía refractiva de la córnea. LXV Ponen Soc Española Oftalmol (Instituto Barraquer de América, Bogotá, 1989), pp. 812–814
A. Arciniegas, L.E. Amaya, Relación entre la tonometría de Goldmann y la presion intravitrea en conejos; Relation between the Goldmann tonometry and the intravitreous pressure in rabbits. Arch. Soc. Am. Oftalmol. Optom. 18(4), 261–275 (1984)
C.R. Ethier, M. Johnson, J. Ruberti, Ocular biomechanics and biotransport. Annu. Rev. Biomed. Eng. 6(1), 249–273 (2004)
M.K. ElMallah, S.G. Asrani, New ways to measure intraocular pressure. Curr. Opin. Ophthalmol. 19(2), 122–126 (2008)
R.L. Stamper, M.F. Lieberman, M.V. Drake, Ch 4 – Intraocular pressure, in: Becker-Shaffers Diagn. Ther. Glaucomas, 8th edn. (Mosby, Edinburgh, 2009), pp. 47–67
S.L.-Y. Woo, A.S. Kobayashi, C. Lawrence, W.A. Schlegel, Mathematical model of the corneo-scleral shell as applied to intraocular pressure–volume relations and applanation tonometry. Ann. Biomed. Eng. 1(1), 87–98 (1972)
Ö.E. Abbasoḡlu, R.W. Bowman, H.D. Cavanagh, J.P. McCulley, Reliability of intraocular pressure measurements after myopic excimer photorefractive keratectomy. Ophthalmology 105(12), 2193–2196 (1998)
C.L.S. Kniestedt, Clinical comparison of contour and applanation tonometry and their relationship to pachymetry. Arch. Ophthalmol. 123(11), 1532–1537 (2005)
M. Lanza, M. Borrelli, M. De Bernardo, M.L. Filosa, N. Rosa, Corneal parameters and difference between Goldmann applanation tonometry and dynamic contour tonometry in normal eyes. J. Glaucoma 17(6), 460–464 (2008)
A. Kotecha, What biomechanical properties of the cornea are relevant for the clinician? Surv. Ophthalmol. 52(6, Supplement), S109–S114 (2007)
Y. Zeng, J. Yang, K. Huang, Z. Lee, X. Lee, A comparison of biomechanical properties between human and porcine cornea. J. Biomech. 34(4), 533–537 (2001)
M.R. DiSilvestro, J.-K.F. Suh, A cross-validation of the biphasic poroviscoelastic model of articular cartilage in unconfined compression, indentation, and confined compression. J. Biomech. 34(4), 519–525 (2001)
M.L. Sears, Miosis and intraocular pressure changes during manometry: mechanically irritated rabbit eyes studied with improved manometric technique. AMA Arch. Ophthalmol. 63(4), 707–714 (1960)
I. Iinuma, K. Uenoyama, T. Sakaguchi, Intraocular pressure changes during tonography. Studies of other pressure tests in rabbit and enucleated human eyes by closed electric manometry. Am. J. Ophthalmol. 61(5 Pt 1), 853–859 (1966)
P. Vareilles, P. Conquet, J.-C. Le Douarec, A method for the routine intraocular pressure (IOP) measurement in the rabbit: range of IOP variations in this species. Exp. Eye Res. 24(4), 369–375 (1977)
J.S. Friedenwald, Contribution to the theory and practice of tonometry. Am J. Ophthalmol. 20(9), 985–1024 (1937)
J.S. Friedenwald, H.F. Pierce, Circulation of the aqueous: VI. Intra-ocular gas exchange. Arch. Ophthalmol. 17(3), 477–485 (1937)
N.J. Schwartz, R.S. Mackay, J.L. Sackman, A theoretical and experimental study of the mechanical behavior of the cornea with application to the measurement of intraocular pressure. Bull. Math. Biophys. 28(4), 585–643 (1966)
M.F. Armaly, The heritable nature of dexamethasone-induced ocular hypertension. Arch. Ophthalmol. 75(1), 32–35 (1966)
W.K. McEwen, Difficulties in measuring intraocular pressure and ocular rigidity, in Glaucoma – Tultzing Symp Tultzing Castle, ed by W. Leydhecker (1966), pp. 97–125
P. Kronfeld, Gross anatomy and embryology of the eye. The Eye 1, 1–66 (1962)
P.R. Greene, Mechanical aspects of myopia, Ph.D. Thesis (Harvard University, Cambridge, 1978)
J.L. Battaglioli, R.D. Kamm, Measurements of the compressive properties of scleral tissue. Invest. Ophthalmol. Vis. Sci. 25(1), 59–65 (1984)
N. Ehlers, J. Hjortdal, The cornea: epithelium and stroma, in Adv. Organ Biol. ed. by J. Fischbarg (Elsevier, Philadelphia, 2005), pp. 83–111
I. Asensio Romero, Valoración del efecto de la oxibuprocaína HCL 0.4 % y del compuesto de tetracaína y oxibuprocaína HCL 0.4 % sobre los valores anatómicos del espesor corneal humano. Ph.D. Thesis (Universitat de València, España, 2007)
M.R. Bryant, P.J. McDonnell, Constitutive laws for biomechanical modeling of refractive surgery. J. Biomech. Eng. 118(4), 473–481 (1996)
E. Sjøntoft, C. Edmund, In vivo determination of young’s modulus for the human cornea. Bull. Math. Biol. 49(2), 217–232 (1987)
J.O. Hjortdal, P. Koch-Jensen, In situ mechanical behavior of the human cornea as evaluated by simultaneous measurement of corneal strain, corneal surface contour, and corneal thickness. Invest. Ophthalmol. Vis. Sci. 33, 895 (1992)
H. Wang, P.L. Prendiville, P.J. McDonnell, W.V. Chang, An ultrasonic technique for the measurement of the elastic moduli of human cornea. J. Biomech. 29(12), 1633–1636 (1996)
L.E. Amaya, A. Arcienegas, Mecánica de la cavidad ocular (Universidad de los Andes, Facultad de Ingeniería, Centro de Estudios e Investigación, Bogotá, 1982)
P.M. Pinsky, D.V. Datye, A microstructurally-based finite element model of the incised human cornea. J. Biomech. 24(10), 907–922 (1991)
K. Buzard, Introduction to biomechanics of the cornea. Refract. Corneal. Surg. 8(2), 127–138 (1992)
K. Anderson, A. El-Sheikh, T. Newson, Application of structural analysis to the mechanical behaviour of the cornea. J. R. Soc. Interface 1(1), 3–15 (2004)
W.J. Dupps Jr., S.E. Wilson, Biomechanics and wound healing in the cornea. Exp. Eye Res. 83(4), 709–720 (2006)
J.Ø. Hjortdal, Extensibility of the normo-hydrated human cornea. Acta Ophthalmol. Scand. 73(1), 12–17 (1995)
C.T. McKee, J.A. Last, P. Russell, C.J. Murphy, Indentation versus tensile measurements of Young’s modulus for soft biological tissues. Tissue Eng. Part B Rev. 17(3), 155–164 (2011)
A.S. Kobayashi, S.L.-Y. Woo, C. Lawrence, W.A. Schlegel, Analysis of the corneo-scleral shell by the method of direct stiffness. J. Biomech. 4(5), 323–330 (1971)
G.W. Nyquist, Rheology of the cornea: experimental techniques and results. Exp. Eye Res. 7(2), 183–188 (1968)
H. Goldmann, Applanation tonometry, in Glaucoma Trans Second Conf., ed by F.W. Newell (Josia Macy Jr Foundation, New York, 1957), pp. 167–220
S.-Y. Woo, A.S. Kobayashi, W.A. Schlegel, C. Lawrence, Nonlinear material properties of intact cornea and sclera. Exp. Eye Res. 14(1), 29–39 (1972)
D.M. Maurice, The cornea and sclera, in The Eye, ed. by H. Davson (Academic Press Inc. (London) Ltd., London, 1984), p. 522
R.P. Vito, P.H. Carnell, Finite element based mechanical models of the cornea for pressure and indenter loading. Refract. Corneal Surg. 8(2), 146–151 (1992)
M.E. Levenston, E.H. Frank, A.J. Grodzinsky, Variationally derived 3-field finite element formulations for quasistatic poroelastic analysis of hydrated biological tissues. Comput. Methods Appl. Mech. Eng. 156(1–4), 231–246 (1998)
M.R. Prausnitz, J.S. Noonan, Permeability of cornea, sclera, and conjunctiva: a literature analysis for drug delivery to the eye. J. Pharm. Sci. 87(12), 1479–1488 (1998)
Y. Ota, S. Mishima, D.M. Maurice, Endothelial permeability of the living cornea to fluorescein. Invest. Ophthalmol. Vis. Sci. 13(12), 945–949 (1974)
L.S. Liebovitch, S. Weinbaum, A model of epithelial water transport. The corneal endothelium. Biophys. J. 35(2), 315–338 (1981)
S. Hodson, C. Wigham, The permeability of rabbit and human corneal endothelium. J. Physiol. 342(1), 409–419 (1983)
A. Edwards, M. Prausnitz, Predicted permeability of the cornea to topical drugs. Pharm. Res. 18(11), 1497–1508 (2001)
M. Borene, V. Barocas, A. Hubel, Mechanical and cellular changes during compaction of a collagen-sponge-based corneal stromal equivalent. Ann. Biomed. Eng. 32(2), 274–283 (2004)
N. Katsube, R. Wang, E. Okuma, C. Roberts, Biomechanical response of the cornea to phototherapeutic keratectomy when treated as a fluid-filled porous material. J. Refract. Surg. Thorofare NJ 1995 18(5), S593–S597 (2002)
D. Prokofiev, J. Dunec, Multiphysics model of soil phenomena near a well, in Proc. Comsol Multiphysics User’s Conf. 2005 (Boston, 2005)
A. Rémond, S. Naïli, T. Lemaire, Interstitial fluid flow in the osteon with spatial gradients of mechanical properties: a finite element study. Biomech. Model. Mechanobiol. 7(6), 487–495 (2008)
S.D. Klyce, C.H. Dohlman, D.W. Tolpin, In vivo determination of corneal swelling pressure. Exp. Eye Res. 11(2), 220–229 (1971)
B.O. Hedbys, C.H. Dohlman, A new method for the determination of the swelling pressure of the corneal stroma in vitro. Exp. Eye Res. 2(2), 122–129 (1963)
S. Mishima, B.O. Hedbys, Physiology of the cornea. Int. Ophthalmol. Clin. 8(3), 527–560 (1968)
T. Seiler, M. Matallana, S. Sendler, T. Bende, Does Bowman’s layer determine the biomechanical properties of the cornea? Refract. Corneal Surg. 8(2), 139–142 (1992)
A. Arciniegas, L.E. Amaya, Bio-structural model of the human eye. Ophthalmologica 180(4), 207–211 (1980)
C.F. Burgoyne, J. Crawford Downs, A.J. Bellezza, J.-K. Francis Suh, R.T. Hart, The optic nerve head as a biomechanical structure: a new paradigm for understanding the role of IOP-related stress and strain in the pathophysiology of glaucomatous optic nerve head damage. Prog. Retin. Eye Res. 24(1), 39–73 (2005)
Y.C. Fung, Biomechanics: Mechanical Properties of Living Tissues (Springer, New York, 1993)
Y.C. Fung, S.C. Cowin, Biomechanics: mechanical properties of living tissues. J. Appl. Mech. 61(4), 1007–1007 (1994)
P.B. Wilhelm, K.M. Van De Graaff, R.W. Rhees, Schaum’s Easy Outline of Human Anatomy and Physiology (McGraw-Hill, New York, 2001)
J.O. Hjortdal, On the biomechanical properties of the cornea with particular reference to refractive surgery. Acta Ophthalmol. Scand. Suppl. 225, 1–23 (1998)
R.F. Jones, D.M. Maurice, New methods of measuring the rate of aqueous flow in man with fluorescein. Exp. Eye Res. 5(3), 208–220 (1966)
H. Wiig, Cornea fluid dynamics I: measurement of hydrostatic and colloid osmotic pressure in rabbits. Exp. Eye Res. 49(6), 1015–1030 (1989)
S.D. Klyce, S.R. Russell, Numerical solution of coupled transport equations applied to corneal hydration dynamics. J. Physiol. 292(1), 107–134 (1979)
S. Cronemberger, C.S. Guimarães, N. Calixto, J.M.F. Calixto, Intraocular pressure and ocular rigidity after LASIK. Arq. Bras. Oftalmol. 72(4), 439–443 (2009)
W.J. Dupps Jr., M.Q. Salomão, R. Ambrósio Jr., Clinical biomechanics and the ocular response analyzer in ectatic disease, in: Keratoconus Keratoectasia Prev. Diagn. Treat., ed. by M.X. Wang, T. Schroeder Swartz (SLACK Incorporated, 2010), pp. 13–28
I.G. Pallikaris, A.I. Dastiridou, M.K. Tsilimbaris, N.G. Karyotakis, H.S. Ginis, Ocular rigidity. Exp. Rev. Ophthalmol. 5(3), 343–351 (2010)
E.T. Detorakis, I.G. Pallikaris, Ocular rigidity: biomechanical role, in vivo measurements and clinical significance. Clin. Exp. Ophthalmol. 41(1), 73–81 (2013)
R. Stodtmeister, Applanation tonometry and correction according to corneal thickness. Acta Ophthalmol. Scand. 76(3), 319–324 (1998)
P.J. Foster, J.-S. Wong, E. Wong, F.-G. Chen, D. Machin, P.T. Chew, Accuracy of clinical estimates of intraocular pressure in Chinese eyes. Ophthalmology 107(10), 1816–1821 (2000)
M. Shimmyo, A.J. Ross, A. Moy, R. Mostafavi, Intraocular pressure, Goldmann applanation tension, corneal thickness, and corneal curvature in Caucasians, Asians, Hispanics, and African Americans. Am J. Ophthalmol. 136(4), 603–613 (2003)
M. Kohlhaas, E. Spoerl, A.G. Boehm, K. Pollack, A correction formula for the real intraocular pressure after LASIK for the correction of myopic astigmatism. J. Refract. Surg. 22(3), 263–267 (2006)
M.B.A. Kohlhaas, Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry. Arch. Ophthalmol. 124(4), 471–476 (2006)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Glossary
- CCT
-
Central corneal thickness
- CH
-
Corneal hysteresis, a measure of viscoelasticity of the cornea (elasticity)
- CRF
-
Corneal resistance factor
- DCT
-
Dynamic contour tonometer
- E
-
Linear elastic modulus (Young’s modulus)
- ECR
-
External corneal radius
- GAT
-
Goldmann applanation tonometer
- ICR
-
Internal corneal radius
- IOP
-
Intraocular pressure
- IOPcc
-
IOP compensated for corneal effects
- IOPg
-
Goldmann equivalent IOP
- IOPt
-
Intraocular pressure measured by means of a tonometer
- LCT
-
Limbal corneal thickness
- PR
-
Poisson’s ratio
- PT
-
Pneumotonometer
- WS
-
Waveform score
Rights and permissions
Copyright information
© 2015 Springer Science+Business Media New York
About this chapter
Cite this chapter
Guarnieri, F.A., Guzmán, A. (2015). Biomechanical Instrumentation in Refractive Surgery. In: Guarnieri, F. (eds) Corneal Biomechanics and Refractive Surgery. Springer, New York, NY. https://doi.org/10.1007/978-1-4939-1767-9_6
Download citation
DOI: https://doi.org/10.1007/978-1-4939-1767-9_6
Published:
Publisher Name: Springer, New York, NY
Print ISBN: 978-1-4939-1766-2
Online ISBN: 978-1-4939-1767-9
eBook Packages: MedicineMedicine (R0)