Abstract

The use of electron paramagnetic resonance (EPR) oximetry for oxygen measurements in deep tissues (>1 cm) is challenging due to the limited penetration depth of the microwave energy. To overcome this limitation, implantable resonators, having a small (0.5 mm diameter) sensory loop containing the oxygen-sensing paramagnetic material connected by a pair of twisted copper wire to a coupling loop (8–10 mm diameter), have been developed, which enable repeated measurements of deep-tissue oxygen levels (pO2, partial pressure of oxygen) in the brain and tumors of rodents. In this study, we have demonstrated the feasibility of measuring dynamic changes in pO2 in the heart and lung of rats using deep-tissue implantable oxygen sensors. The sensory loop of the resonator contained lithium octa-n-butoxynaphthalocyanine (LiNc-BuO) crystals embedded in polydimethylsiloxane (PDMS) polymer and was implanted in the myocardial tissue or lung pleura. The external coupling loop was secured subcutaneously above chest. The rats were exposed to different breathing gas mixtures while undergoing EPR measurements. The results demonstrated that implantable oxygen sensors provide reliable measurements of pO2 in deep tissues such as heart and lung under adverse conditions of cardiac and respiratory motions.

Keywords

Oximetry Electron paramagnetic resonance (EPR) Implantable oxygen sensors Myocardial tissue Lung pleura 

Notes

Acknowledgments

This work was supported by National Institutes of Health (NIH) grant 5R01EB004031.

References

  1. 1.
    Ahmad R, Kuppusamy P (2010) Theory, instrumentation, and applications of electron paramagnetic resonance oximetry. Chem Rev 110:3212–3236CrossRefPubMedPubMedCentralGoogle Scholar
  2. 2.
    Hou H, Dong R, Li H, Williams B, Lariviere JP, Hekmatyar SK, Kauppinen RA, Khan N, Swartz H (2012) Dynamic changes in oxygenation of intracranial tumor and contralateral brain during tumor growth and carbogen breathing: a multisite EPR oximetry with implantable resonators. J Magn Reson 214:22–28CrossRefPubMedGoogle Scholar
  3. 3.
    Hou H, Li H, Dong R, Mupparaju S, Khan N, Swartz H (2011) Cerebral oxygenation of the cortex and striatum following normobaric hyperoxia and mild hypoxia in rats by EPR oximetry using multi-probe implantable resonators. Adv Exp Med Biol 701:61–67CrossRefPubMedPubMedCentralGoogle Scholar
  4. 4.
    Li H, Hou H, Sucheta A, Williams BB, Lariviere JP, Khan MN, Lesniewski PN, Gallez B, Swartz HM (2010) Implantable resonators – a technique for repeated measurement of oxygen at multiple deep sites with in vivo EPR. Adv Exp Med Biol 662:265–272CrossRefPubMedPubMedCentralGoogle Scholar
  5. 5.
    Pandian RP, Parinandi NL, Ilangovan G, Zweier JL, Kuppusamy P (2003) Novel particulate spin probe for targeted determination of oxygen in cells and tissues. Free Radic Biol Med 35:1138–1148CrossRefPubMedGoogle Scholar
  6. 6.
    Chacko SM, Khan M, Kuppusamy ML, Pandian RP, Varadharaj S, Selvendiran K, Bratasz A, Rivera BK, Kuppusamy P (2009) Myocardial oxygenation and functional recovery in infarct rat hearts transplanted with mesenchymal stem cells. Am J Physiol Heart Circ Physiol 296:H1263–H1273CrossRefPubMedPubMedCentralGoogle Scholar

Copyright information

© Springer Science+Business Media, LLC 2014

Authors and Affiliations

  • Brian K. Rivera
    • 1
  • Shan K. Naidu
    • 1
  • Kamal Subramanian
    • 1
  • Matthew Joseph
    • 1
  • Huagang Hou
    • 2
  • Nadeem Khan
    • 2
  • Harold M. Swartz
    • 3
  • Periannan Kuppusamy
    • 2
  1. 1.Department of Internal MedicineDavis Heart and Lung Research Institute, The Ohio State University Wexner Medical CenterColumbusUSA
  2. 2.EPR Center for the Study of Viable Systems, Department of RadiologyGeisel School of Medicine at DartmouthLebanonUSA
  3. 3.EPR Center for the Study of Viable SystemsThe Geisel School of Medicine at DartmouthLebanonUSA

Personalised recommendations