Selective Antibody Responsive Membrane Electrodes

  • M. Y. Keating

Abstract

Demands of sensitivity, speed and accuracy of immunoassay methods in the health care industry have stimulated the interest of scientists in many disciplines. Although there exist well-established assays, alternative methods are still being sought. A considerable advance has been made in Potentiometric immuno-sensors alone. The method described in this chapter is different from straight forward enzyme labeled immuno techniques (e. g., Meyerhoff and Rechnitz, 1979; Boitieux, Desmet and Thomas, 1979; Alexander and Maitra, 1982) where an electrometrically measurable product is liberated by the enzyme label. This class of membrane electrodes respond to specific antibodies through modulation of a background potential fixed by a marker ion. Solsky and Rechnitz (1981) showed that a PVC (polyvinyl chloride) matrix containing DNP-ionophore conjugate responded to anti-DNP antibodies specifically. Keating and Rechnitz (1983, 1984) found that cortisol-ionophore and digoxin-ionophore membrane electrodes are specific to their corresponding antibodies. The term “ionophore” refers to a class of macro-organic molecules which are capable to solubilize specifically an inorganic ion of the suitable size in organic mediums. The ionophore used were benzo-crown ethers and the marker ion was potassium ion.

Keywords

Crown Ether Membrane Electrode Potentiometric Response Rabbit Serum Albumin Conjugate Molecule 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Alexander, P.W.; Maitra, C. (1982). Enzyme-Linked Immunoassay of Human Immunoglobulin G with the Fluoride Ion Selective Electrode. Anal. Chem. 54: 68–71.PubMedCrossRefGoogle Scholar
  2. Boitieux, J.-L.; Desmet, G.; Thomas, D. (1979). An “Antibody Electrode,” Preliminary Report on a New Approach in Enzyme Immunoassay. Clin. Chem. 25: 318–321.PubMedGoogle Scholar
  3. Butler Jr., V.P.; Chen, J.P. (1967). Digocin Specific Antibodies. Proc. Natl. Acad. Sci. U. S. A. 57: 71–78.PubMedCrossRefGoogle Scholar
  4. Butler Jr., V.P.; Tse-Eng, D. (1982). Immunoassay of Digoxin and Other Cardiac Glycosides. “Methods in Enzymology”, Langone, J.J.; Van Vunakis, H., Eds.; Academic Press: New York 84: 558–577.PubMedCrossRefGoogle Scholar
  5. Collins, S.; Janata, J. (1982). A Critical Evaluation of the Mechanism of Potential Response of Antigen Polymer Membranes to the Corresponding Antiserum. Anal. Chim. Acta 136: 93–99.CrossRefGoogle Scholar
  6. Erlanger, B.F.; Beiser, S.M. (1964). Antibodies Specific for Ribonucleosides and Ribonucleotides and their Reaction with Deoxyribonucleic Acid (DNA). Proc. Natl. Acad. Sci. U. S. A. 52: 68–74.PubMedCrossRefGoogle Scholar
  7. Evered, D.C. (1972). The Binding of Digoxin by the Serum Proteins. Eur. J. Pharmacol. 18: 236–244.PubMedCrossRefGoogle Scholar
  8. Farah, A. (1945). On the Combination of Some Cardio-Active Glycosides with Serum Proteins. J. Pharmacol. Exp. Ther. 83: 143–157.Google Scholar
  9. Feigenbaum, W.M.; Michel, R.H. (1971). Novel Polyamides from Macrocyclic Ethers. J. Polym. Sci. 9: 817–820.Google Scholar
  10. Holtzman, J.L.; Shafer, R.B. (1975). Radioimmunoassay of Digoxin: Effect of Albumin. Clin. Chem. 21: 636–637.Google Scholar
  11. Keating, M.Y.; Rechnitz, G.A. (1983). Cortisol Electrode. Analyst (London) 108: 766–768.CrossRefGoogle Scholar
  12. Keating, M.Y.; Rechnitz, G.A. (1984). Potentiometric Digoxin Antibody Measurements with Antigen-Ionophore Based Membrane Electrodes. Anal. Chem. 56: 801–806.PubMedCrossRefGoogle Scholar
  13. Lukas, D.S.; De Martino, A.G. (1969). Binding of Digoxin and Some Related Cardenolides to Human Plasma Proteins. J. Clin. Invest. 48: 1041–1053.PubMedCrossRefGoogle Scholar
  14. Meyerhoff, M.E.; Rechnitz, G.A. (1979). Electrode-Based Enzyme Immunoassays Using Urease Conjugates. Anal. Biochem. 95: 483–493.PubMedCrossRefGoogle Scholar
  15. Shaw, W. (1975). Radioimmunoassay of Digoxin: Effect of Albumin. Clin. Chem. 21: 636.PubMedGoogle Scholar
  16. Smith, T.W.; Butler Jr., V.P.; Haber, E. (1970). Characterization of Antibodies of High Affinity and Specificity for the Digitalis Glycoside Digoxin. Biochem. 9: 331–337.CrossRefGoogle Scholar
  17. Solsky, R.L.; Rechnitz, G.A. (1981). Preparation and Properties of an Antibody-Selective Membrane Electrode. Anal. Chim. Acta 123: 135–141.CrossRefGoogle Scholar
  18. Ungaro, R.; El Haj, B.; Smid, J. (1976). Substituent Effects on the Stability of Cation Complexes of 4’-Substituted Monobenzo Crown Ethers. J. Am. Chem. Soc. 98: 5198–5202.CrossRefGoogle Scholar
  19. Voshall, D.L.; Hunter, L.; Grady, H.J. (1975). Effect of Albumin on Serum Digoxin Radioimmunoassays. Clin. Chem. 21: 402–406.PubMedGoogle Scholar

Copyright information

© Springer Science+Business Media New York 1987

Authors and Affiliations

  • M. Y. Keating
    • 1
  1. 1.Department of ChemistryUniversity of DelawareNewarkUSA

Personalised recommendations