Abstract
Spacecraft cryocoolers continue to attract interest in the space science community. To date, many Stirling cycle cryocoolers have been characterized by JPL in a number of performance areas including thermal performance. A number of factors are used to evaluate the efficiency and cooling power of cryocoolers at cryogenic coldtip temperatures. A comparison of the measured thermal performance of several cryocoolers is presented.
The various cryocoolers tested by JPL include single compressor/single displacer, back-to-back dual compressor/dual displacer, back-to-back dual compressor/single displacer, and in-line single compressor/single displacer configurations. These cryocoolers were designed with various compressor and displacer sizes and strokes and were designed to operate at a drive frequency that is particular to each cooler. The design differences between various coolers complicates their comparison. This paper aims to evaluate the thermal performance data so that cooler-to-cooler comparisons can be made. As part of these comparisons, the paper explores the measured sensitivity of thermal performance to a wide range of operational variables. These include piston and displacer stroke, piston/displacer phase, fill pressure, heatsink temperature, and drive frequency. A multivariable plot format aids in the understanding of the complex interdependence of input power, coldtip temperature, coldtip heat load, specific power (efficiency), and the operational variable.
This paper provides the community with insight into the expected performance and limitations of state-of-the-art cryocoolers.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
V.Y. Kotsubo, D.L. Johnson, and R.G. Ross Jr., “Calorimetric Thermal-Vacuum Performance Characterization of the BAe 80K Space Cryocooler,” 27th Intersociety Energy Conversion Engineering Conference. SAE Paper No. 929037, San Diego, August, 1992.
V. Kotsubo, D.L. Johnson, and R.G. Ross, Jr., “Cold-tip Off-state Conduction Loss of Miniature Stirling-Cycle Cryocoolers,” Adv. Cryo. Engin., vol. 37B (1991), p. 10327.
R.G. Rossjr., D.L. Johnson, and, V.Y. Kotsubo, BAe 80K Stirling Cryocooler: Performance Characterization. JPL Internal Document D-9912, May 1992.
D.L. Johnson, G.R. Mon, and R.G. Rossjr., BAe 55k Development Model Cryocooler: Performance Characterization. JPL Internal Document D-10276, May 1993.
G.T. Smedley, D.L. Johnson, and R.G. Rossjr., Stirling Technology Company 80K TDM Cryocooler: Performance Characterization. JPL Internal Document D-11270, July 1993.
G.T. Smedley, D.L. Johnson, and R.G. Rossjr., Sunpower 140K Cryocooler: Performance Characterization. JPL Internal Document D-l 1085, July 1993.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1995 Springer Science+Business Media New York
About this chapter
Cite this chapter
Smedley, G.T., Mon, G.R., Johnson, D.L., Ross, R.G. (1995). Thermal Performance of Stirling-Cycle Cryocoolers: A Comparison of JPL-Tested Coolers. In: Ross, R.G. (eds) Cryocoolers 8. Springer, Boston, MA. https://doi.org/10.1007/978-1-4757-9888-3_19
Download citation
DOI: https://doi.org/10.1007/978-1-4757-9888-3_19
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4757-9890-6
Online ISBN: 978-1-4757-9888-3
eBook Packages: Springer Book Archive