Abstract

Epithermal neutron beams are currently being developed for use in Neutron Capture Therapy (NCT). They have the advantage over thermal neutron beams in that they can achieve better penetration and can therefore treat deep-seated tumors. It has been shown that the optimum energy range for epithermal neutrons is approximately from 0.5eV to 10keV1; energy above that will cause significant damage due to proton recoil.

Keywords

Fuel Element Neutron Beam Boron Neutron Capture Therapy Reactor Core Epithermal Neutron 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    B.J. Mcgregor and B.J. Allen, “Filtered beam dose distributions for boron neutron capture therapy brain tumours,” in Proc. First Int. Symp. Neutron Capture Therapy, R.G. Fairchild and G.L. Brownell eds., Brookhaven National Laboratory, 1983.Google Scholar
  2. 2.
    J.F. Briesmeisterk, ed., “MCNP - A general Monte Carlo code for neutron and photon transport, version 3A,” Los Alamos National Laboratory, LA-7396—M, Rev. 2 1986.Google Scholar
  3. 3.
    R.M. Brugger, T.J. Less, and G.G. Passmore, “An intermediate-energy neutron beam for NCT at MURR,” Workshop on NCT, Jan. 1986, BNL-51994, Brookhaven National Laboratory, 1986.Google Scholar
  4. 4.
    H.B. Liu, et al., “Enhancement of the epithermal neutron beam used for BNCT at the BMRR,” Submitted to International Journal of Radiation Oncology, Biology and Physics, 1993.Google Scholar
  5. 5.
    R.M. Moss, “Review of reactor-based neutron beam development for BNCT applications,” 5th International Symposium on Neutron Capture Therapy for Cancer, Ohio State University, Columbus, Ohio, USA, on 13–17th September 1992.Google Scholar
  6. 6.
    S.D. Clement, et al., “Monte Carlo methods of neutron beam design for neutron capture therapy at the MIT Research Reactor (MITR-I1),” in Neutron Beam Design, Development, and Performance for Neutron Capture Therapy, edited by O.K. Harling, et al., Plenum Press, NY, 1990.Google Scholar
  7. 7.
    R.L. Moss, et al., “Design, construction and installation of an epithermal neutron beam for BNCT at the High Flux Reactor Petten,” Progress in Neutron Capture Therapy for Cancer, edited by B.J. Allen, et al., Plenum Press, NY, 1992.Google Scholar