Effects of High Intensity Cryogenic Irradiation and Magnetic Field on Temperature Sensors

  • Yu. P. Filippov
  • V. V. Golikov
  • E. N. Kulagin
  • V. G. Shabratov
Part of the Advances in Cryogenic Engineering book series (ACRE, volume 43)


Four types of commercially available cryogenic thermometers were irradiated by gamma and/or neutron sources. These sensors are the well known rhodium-iron and platinum resistance thermometers, carbon resistance thermometer of TVO type and thin-film germanium resistance sensors; they can operate over the 1.5 K to 350 K range (14 K — for platinum sensor). The radiation source for experiments is the Fast Pulsed Reactor of Frank Laboratory for Neutron Physics, JINR. The total doses were about 1016 n/cm2 and 105 Gy at average energy of the fast neutrons of 1 MeV. The thermometers were calibrated at cryogenic temperatures and irradiated at 290 K, after that the comparison of the new calibration to the old one was made. Then the thermometers were irradiated and calibrated in-situ at 77.4 K. In addition, several tests of the thin-film germanium, platinum and TVO-carbon sensors were performed in the magnetic field. The obtained results are discussed.


Fast Neutron Temperature Shift Boron Carbide Neutron Fluence Platinum Resistance Thermometer 


Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.


  1. 1.
    S.S. Court, D.S. Holmes and P.R. Swinehart, Neutron and gamma radiation effects on cryogenic temperature sensors, in: “Temperature, Its Measurements and Control in Science and Industry”, J.F.Schooley ed., American Institute of Physics, New York, (1992),p.l237.Google Scholar
  2. 2.
    S.S. Court and D.S. Holmes, Effects of cryogenic irradiation on temperature sensors, in: “Advances in Cryogenic Engineering”, Plenum Press, New York (1996), vol. 41B, p.1707.CrossRefGoogle Scholar
  3. 3.
    ATLAS Collaboration, Technical Proposal, CERN/LHCC/94–43 (1993), M.Shupe, Private communication.Google Scholar
  4. 4.
    V.I. Datskov and J.G. Weisend II, Characteristics of russian carbon resistance (TVO) cryogenic thermometers, Cryogenics 34:425 (1994) ICEC Supplement.CrossRefGoogle Scholar
  5. 5.
    D.I. Astrov, G.S Abilov, B.I Alshin et al. Investigations in the field of thermometry and thermophysical measurements, Proceedings of VNIIFTRI, Moscow (1967–1983), in russian.Google Scholar
  6. 6.
    V. Mitin, Y. Thorik and E. Venger, New type of thin film germanium resistance thermometer for use in a wide temperature range, in: “Proc. ICEC 16, Part I”, (1996), Kitakyuishu, Japan, p.653.Google Scholar
  7. 7.
    F. Pavese, V.M. Malyshev, P.P.M. Steur, D. Ferri and D. Giraudi, Routine calibration of the cryogenic thermometers in the range 1.5–350 K with an accuracy up to the millikelvin level, in:“Advances in Cryogenic Engineering”, Plenum Press, New York (1996), vol. 41B, p.1683.CrossRefGoogle Scholar
  8. 8.
    A. Cheplakov, V. Golikov, S .Golubyh et al., Radiation hardness of GaAs preamplifiers for liquid argon calorimetry at LHC, 80805 Munich, Forringer ring 6, MPI-PhE/96–15.Google Scholar
  9. 9.
    M.P. Orlova, O.F. Pogorelova and S.A. Ulybin. “Low Temperature Thermometry”, Energoatomizdat, Moscow (1987), in russian.Google Scholar
  10. 10.
    T. Haruyama, N. Kimura, K. Tanaka and A. Yamamoto, Temperature measurement under high magnetic fields around 1.8 K by using CGR thermometers, in: “Proc. ICEC 16, Part I”, (1996), Kitakyuishu, Japan, p.649.Google Scholar

Copyright information

© Springer Science+Business Media New York 1998

Authors and Affiliations

  • Yu. P. Filippov
    • 1
  • V. V. Golikov
    • 1
  • E. N. Kulagin
    • 1
  • V. G. Shabratov
    • 1
  1. 1.Joint Institute for Nuclear ResearchDubnaRussia

Personalised recommendations