A cryogenic system1,2 which has a capacity of 300 W at 1.75 K, 1000 W at 4 K and 30 kW at 80 K has been operating for more than 10 years. It is used to cool the superconducting toroidal magnet of the TORE SUPRA Tokamak3. The 1.75 K refrigeration stage is constituted by 3 Hell saturated baths (cold sources) linked to the 18 Hell pressurized baths of the toroidal coils. The Hell saturated bath pumping system is achieved part at low temperature by two centrifugal compressors, part at room temperature by two oil ring pumps. This pumping system has a very large pumping range characteristic from 0.003 to 0.040 kg/s and a great operating reliability. The safety devices and protections against quench are peculiar.

Keywords

Centrifugal Compressor Safety Valve Toroidal Field Safety Device Superfluid Helium 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    G. Claudet et al. Design of the cryogenic system for the TORE SUPRA tokamak, Cryogenics 26:443 (1986)CrossRefGoogle Scholar
  2. 2.
    G. Bon Mardion et al.,Normal Operating of the 1.8 K TORE SUPRA Cryogenic system 1. Proc 13th ICEC Beijing CRYOGENICS (1990)30S 566–570Google Scholar
  3. 3.
    R. Aymar et al., IEEE Trans. Magn (1979) MAG 15 5426545Google Scholar
  4. 4.
    G. Bon Mardion et al. A Magnetic safety valve cryogenics 79:425 (1979)CrossRefGoogle Scholar
  5. 5.
    J.L. Duchateau et al. Monitoring and controlling TORE SUPRA toroidal field system. IEEE Trans.Magn. 27:2053(1991)CrossRefGoogle Scholar