Advertisement

Cryopump Cooled with a Dual Heat Pipe

  • S. Buhler
  • A. Horbowa
  • J. P. Thermeau
Part of the Advances in Cryogenic Engineering book series (ACRE, volume 43)

Abstract

A cryopumping system providing a large pumping speed in the centre of a cyclotron accelerating chamber has been built. The cooling of the cryopanels supplied from cryorefrigerators located at some distance is efficiently transfered with a dual heat pipe operating with LN2 and LH2 circulating by gravity or even with He at moderate pressure in a natural convection mode. The design of the cryopanel is described. Performances for cooldown and steady state operation are given.

Keywords

Heat Pipe Moderate Pressure Cooling Module Cooling Power Steady State Operation 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    The SPIRAL. “Radioactive Ion Beam Facility”, GANIL Report R9402 may 1994.Google Scholar
  2. 2.
    S. Buhler, A. Horbowa. “The AGOR Cryopump”, Proc. 12th Intern. Conf. on Cyclotrons, Berlin, May 1989.Google Scholar
  3. 3.
    A. Horbowa, S. Buhler. “Le Système de cryopompage du cyclotron AGOR”, Vide et Couches Minces. No 252, 1990.Google Scholar