Advertisement

Assessment of Lung Function in Mechanically Ventilated Patients

  • J. H. T. Bates

Abstract

Lung function is often compromised in respiratory failure. Therefore, the management of mechanically ventilated patients is facilitated by knowing the mechanical properties of the patient’s lungs. Monitoring mechanical lung function regularly may help in the diagnosis of adverse events such as onset of pulmonary edema or blockage of the endotracheal tube. Ventilator-induced lung injury (VILI), due to over-stretch of the pulmonary tissues, may be minimized if the relationships between volume, flow and pressure in the lungs are understood and ventilatory parameters are chosen accordingly.

Keywords

Viscoelastic Model Tracheal Stenosis Lung Mechanic Lung Volume Reduction Surgery Forced Oscillation Technique 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Mead J, Whittenberger JL (1953) Physical properties of human lungs measured during spontaneous respiration. J Appl Physiol 5: 779–796Google Scholar
  2. 2.
    Peslin R, Felicio da Silva J, Chabot F, Duvivier C (1992) Respiratory mechanics studied by multiple linear regression in unsedated ventilated patients. Eur Respir J 5: 871–878PubMedGoogle Scholar
  3. 3.
    Dechman GS, Chartrand DA, Ruiz-Neto RP, Bates JHT (1995) The effect of changing end-expiratory pressure on respiratory system mechanics in open-and closed-chested anesthetized, paralyzed patients. Anesth Analg 81: 279–286PubMedGoogle Scholar
  4. 4.
    Fahy BG, Barnas GM, Nagle SE, Flowers JL, Njoku MJ, Agarwal M (1996) Effects of Trendelenburg and reverse Trendelenburg postures on lung and chest wall mechanics. J Clin Anesth 8: 236–244PubMedCrossRefGoogle Scholar
  5. 5.
    Fredberg JJ, Keefe DH, Glass GM, Castile RG, Franz ID (1984) Alveolar pressure nonhomogeneity during small-amplitude high-frequency oscillation. J Appl Physiol 57: 788–800PubMedGoogle Scholar
  6. 6.
    Hantos Z, Daroczy B, Suki B, Nagy S, Fredberg JJ (1992) Input impedance and peripheral inhomogeneity of dog lungs. J Appl Physiol 72: 168–178PubMedCrossRefGoogle Scholar
  7. 7.
    Otis AB (1986) History of respiratory mechanics. In: Cherniack NS (ed) Handbook of Physiology. The Respiratory System, vol III. Am Physiol Soc, Bethesda, pp 1–12Google Scholar
  8. 8.
    Fabry B, Guttman J, Eberhard L, Wolff G (1994) Automatic compensation of endotracheal tube resistance in spontaneously breathing patients. Technol Health Care 1: 281–291Google Scholar
  9. 9.
    Guttman J, Eberhard L, Fabry B, et al (1995) Time constant/volume relationship of passive expiration in mechanically ventilated ARDS patients. Eur Respir J 8: 114–120CrossRefGoogle Scholar
  10. 10.
    Bersten AD (1998) Measurement of overinflation by multiple linear regression analysis in patients with acute lung injury. Eur Respir J 12: 526–532PubMedCrossRefGoogle Scholar
  11. 11.
    Salazar E, Knowles JH (1964) An analysis of pressure-volume characteristics of the lungs. J Appl Physiol 19: 97–104PubMedGoogle Scholar
  12. 12.
    Colebatch HJH, Ng CKY, Nikov N (1979) Use of an exponential function for elastic recoil. J Appl Physiol 46: 387–393PubMedGoogle Scholar
  13. 13.
    Harris RS, Hess DR, Venegas JG (2000) An objective analysis of the pressure-volume curve in the acute respiratory distress syndrome. Am J Respir Crit Care Med 161: 432–439PubMedCrossRefGoogle Scholar
  14. 14.
    Hickling K (1998) The pressure-volume curve is greatly modified by recruitment. Am J Respir Crit Care Med 158: 194–202PubMedCrossRefGoogle Scholar
  15. 15.
    Otis AB, McKerrow CB, Bartlett RA, et al (1956) Mechanical factors in distribution of pulmonary ventilation. J Appl Physiol 8: 427–443PubMedGoogle Scholar
  16. 16.
    Mead J (1969) Contribution of compliance of airways to frequency-dependent behavior of lungs. J Appl Physiol 26: 670–673PubMedGoogle Scholar
  17. 17.
    Mount LE (1955) The ventilation flow-resistance and compliance of rat lungs. J Physiol (Lond) 127: 157–167Google Scholar
  18. 18.
    Similowski T, Bates JHT (1991) Two-compartment modelling of respiratory system mechanics at low frequencies: gas redistribution or tissue rheology? Eur Respir J 4: 353–358PubMedGoogle Scholar
  19. 19.
    Bates JHT, Ludwig MS, Sly PD, Brown K, Martin JG, Fredberg JJ (1988) Interrupter resistance elucidated by alveolar pressure measurement in open-chest normal dogs. J Appl Physiol 65: 408–414PubMedGoogle Scholar
  20. 20.
    Fredberg JJ, Ingram RH, Castile RG, Glass GM, Drazen JM (1985) Nonhomogeneity of lung response to inhaled histamine assessed with alveolar capsules. J Appl Physiol 58: 1914–1922PubMedGoogle Scholar
  21. 21.
    Ludwig MS, Romero PV, Sly PD, Fredberg JJ, Bates JHT (1990) Interpretation of interrupter resistance after histamine-induced constriction in the dog. J Appl Physiol 68: 1651–1656PubMedGoogle Scholar
  22. 22.
    Rossi A, Gottfried SB, Higgs BD, Zocchi L, Grassino A, Milic-Emili J (1985) Respiratory mechanics in mechanically ventilated patients with respiratory failure. J Appl Physiol 58: 1849–1858PubMedGoogle Scholar
  23. 23.
    D’Angelo E, Tavola M, Milic-Emili J (2000) Volume and time dependence of respiratory system mechanics in normal anaesthetized paralysed humans. Eur Respir J 16: 665–672PubMedCrossRefGoogle Scholar
  24. 24.
    Bates JHT, Rossi A, Milic-Emili J (1985) Analysis of the behavior of the respiratory system with constant inspiratory flow. J Appl Physiol 58: 1840–1848PubMedGoogle Scholar
  25. 25.
    Peslin R, Fredberg JJ (1986) Oscillation mechanics of the respiratory system. In: Cherniack NS (ed) Handbook of Physiology, The Respiratory System, vol III. Am Physiol Soc, Bethesda, pp 145–177Google Scholar
  26. 26.
    Beraldo PS, Mateus SR, Arujo LM, Horan TA (2000) Forced oscillation technique to detect and monitor tracheal stenosis in a tetraplegic patient. Spinal Cord 38: 445–447PubMedCrossRefGoogle Scholar
  27. 27.
    Kaczka D, Ingenito EP, Body SC, et al (2001) Inspiratory lung impedance in COPD: effects of PEEP and immediate impact of lung volume reduction surgery. J Appl Physiol 90: 18331841Google Scholar

Copyright information

© Springer Science+Business Media New York 2002

Authors and Affiliations

  • J. H. T. Bates

There are no affiliations available

Personalised recommendations