Experimental and theoretical evaluations of fixed beds of granular dextran beads for the purification of uremic lymph are described. This work was inspired by reported success in treatment of chronic uremia by repeated collection, purification, and reinfusion of thoracic duct lymph.

The experimental program demonstrated that a rapid and essentially complete separation of low molecular weight metabolites from lymph proteins in a gel bed is possible, but that the protein-rich effluent is somewhat diluted by the occurrence of viscous flow instabilities in the trailing protein boundary.

A complete theoretical description of the system which gave excellent agreement with observed behavior was achieved using a longitudinal dispersion model and parameters evaluated from available dispersion and mass transfer coefficient correlations and from analysis of some of the experimental data. The model and parameters were then used to investigate the effects of such variables as column volume, column configuration, displacement velocity, etc. on the separation process, using a digital computer. Means of stabilizing the trailing protein boundary are outlined, and general considerations involved in arriving at a final practical system design are discussed.


Mass Transfer Coefficient Mass Transfer Resistance Artificial Kidney Effluent Volume Thoracic Duct Lymph 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.


Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Literature Cited

  1. 1.
    Blackwell, R. J., Rayne, J. R., and Terry, W. M., Trans. Am. Inst. Mining Met. Petrol. Engrs., 216, 1 (1959).Google Scholar
  2. 2.
    Cohn, E. J., and Edsall, J. T., Proteins, Amino Acids, and Peptides, Reinhold, New York, 1943.Google Scholar
  3. 3.
    Dumore, J. M., Soc. Petrol. Engrs. J., 4, 356 (1964).Google Scholar
  4. 4.
    Glueckauf, E., Trans. Faraday Soc., 51, 1540 (1955).CrossRefGoogle Scholar
  5. 5.
    Helfferich, F., Ion Exchange, McGraw-Hill, New York, 1962.Google Scholar
  6. 6.
    Hougen, O. A., Watson, K. M., and Ragatz, R. A., CPP Charts, Wiley, New York, 1960.Google Scholar
  7. 7.
    Klinkenberg, A., and Sjenitzer, F., Chem. Eng. Science, 6, 258 (1956).CrossRefGoogle Scholar
  8. 8.
    Lightfoot, E. N., Sanchez-Palma, R. J., and Edwards, D. O., “Chromatography and Allied Fixed-Bed Separations Processes”, New Chemical Engineering Separation Techniques, H. M. Schoen, Ed., Wiley, New York, 1962.Google Scholar
  9. 9.
    Perkins, T. K., and Johnston, O. C., Soc. Petrol. Engrs. J., 3, 70 (1963).Google Scholar
  10. 10.
    Reid, R. C., and Sherwood, T. K., The Properties of Gases and Liquids, McGraw-Hill, New York, 1958.Google Scholar
  11. 11.
    Sarles, H. E., Artz, C. P., Smith, G. H., Hargest, T. S., and Remmers, A. R., Trans. Am. Soc. Artif. Int. Organs, 11, 165 (1965).CrossRefGoogle Scholar
  12. 12.
    Sarles, H. E., Smith, G. H., Fish, J. C., Artz, C. P., Hargest, T. S., and Remmers, A. R., Trans. Am. Soc. Artif. Int. Organs, 12, 33 (1966).Google Scholar
  13. 13.
    Slobod, R. L., and Howlett, W. E., Soc. Petrol. Engrs. J., 4, 1 (1964).Google Scholar
  14. 14.
    Weinstein, A. B., Trans. Am. Soc. Artif. Int. Organs, 10, 265 (1964).Google Scholar
  15. 15.
    Weinstein, A. B., Wen, S. F., Shelp, W. D., and Pellett, J. R., Trans. Am. Soc. Artif. Int. Organs, 12, 26 (1966).Google Scholar

Copyright information

© Springer Science+Business Media New York 1967

Authors and Affiliations

  • D. O. Cooney
    • 1
  • E. N. Lightfoot
    • 1
  • A. B. Weinstein
    • 2
  • S. F. Wen
    • 2
  • W. D. Shelp
    • 2
  1. 1.Department of Chemical EngineeringUniversity of WisconsinMadisonUSA
  2. 2.Department of MedicineUniversity of WisconsinMadisonUSA

Personalised recommendations