Advertisement

Evaluation of the Decimal Reduction Time of a Sterilization Process in Pharmaceutical Production

  • Jeffrey Eisele
  • Amy Racine
  • Mauro Gasparini
Chapter

Abstract

Consider measuring the effectiveness of sterilization during the production of a pharmaceutical substance. The decimal reduction time, D-value, of a steriliza­tion process is defined to be the time required to reduce the number of microor­ganisms present by a factor of 10. Because the issue of concern is the rate of bacterial death this process is often referred to as “Death Kinetics.” Different methods for sterilization are possible depending on the nature of the pharmaceu­tical product, for example, heat treatment. Since the D-value depends to a large extent on environmental conditions, it is necessary to determine experimentally the substance specific D-value for each substance that is sterilized by means of moist heat. If the D-value of the substance is the same as that of a reference substance, typically water, the sterilization process is deemed successful.

Keywords

Test Substance Microbial Count Sterilization Process ASCII File Individual Assay 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. American National Standard (1991). Guidelines for the use of ethylene oxide and steam biological indicators in industrial sterilization processes. Association for the Advancement of Medical Instrumentation.Google Scholar
  2. Cook, R.D. and Weisberg, S. (1982). Residuals and Influence in Regression. Chapman & Hall, New York.MATHGoogle Scholar
  3. Fieller, E.C. (1954). Some problems in interval estimation. Journal of the Royal Statistical Society, Series B 16, 175–185.MathSciNetMATHGoogle Scholar
  4. Heintz, M., Urban, S., Gay, M., and Bühlmann, X. (1976). The production of spores of Bacillus Stearothermophilus with constant resistance to heat and their use as biological indicators during development of an aqueous solution for injection. Pharmaceutica Acta Helvetiae 51, 1337–1343.Google Scholar
  5. International Standard (1994). Sterilization of health care products—Biological indicators. ISO 11138–1, 2“d ed., 1994–10-01.Google Scholar
  6. Kota, S., Johnson, N.L. and Read, C.B. (1983). Encyclopedia of Statistical Sciences, Vol. 3. Wiley, New York.Google Scholar
  7. Meeker, W.Q. and Escobar, L.A. (1995). Teaching about approximate confidence regions based on maximum likelihood estimation. The American Statistician 49, 48–53.Google Scholar

Copyright information

© Springer Science+Business Media New York 2001

Authors and Affiliations

  • Jeffrey Eisele
    • 1
  • Amy Racine
    • 1
  • Mauro Gasparini
    • 2
  1. 1.Department of BiostatisticsNovartis Pharma AGBaselSwitzerland
  2. 2.Dipartimento di MatematicaPolitecnico di TorinoTorinoItaly

Personalised recommendations