Skip to main content

Part of the book series: Earlier Brown Boveri Symposia ((EBBS))

  • 240 Accesses

Summary

The transient recovery voltage (trv) which appears at the opening of a circuit breaker is dependent on the lumped and distributed impedances of the elements of the network and busbars. It is important to determine whether the low impedances of the bars, or the presence of small capacitances connected to the bars, influences the breaking. It is intended to show how the different elements and arrangements of a station may be taken into account and how they may influence the trv. Due to the short lengths of these elements, the time under consideration is very short, less than 1 Ns; consequently, special attention will be given on the representation of the impedances together with a description of possible methods to study this phenomenon.

A brief survey of the results obtained by a working group of CIGRE gives the main results and a simple method for evaluation. Simple estimates of the influence of the resistance of an arc permits a discussion of the true importance of the initial transient recovery voltage (itrv) in the network or in a test-station.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. G. Catenacci, Electra 46 (1976) 39

    Google Scholar 

  2. G. Köppl and P. Geng, Brown Boveri Review 53 (1966) 311

    Google Scholar 

  3. E. Bolton, M. J. Battisson, B. J. Bickford, M. G. Dweck, R. L. Jackson and M. Scott, Proc. IEEE 117 (1970) 771

    Google Scholar 

  4. B. Calvino, G. Mazza, B. Mazzoleni and V. Villa, Some Aspects of the Stresses Supported by HV Circuit-Breakers Clearing a Short-Circuit, Cigré Report 13–08 (1974)

    Google Scholar 

  5. D. E. Hedman, IEEE Trans PAS 84 (1965) 200

    Article  Google Scholar 

  6. C. Dubanton, Calcul approché des parametres d’une ligne de transport, Valeurs homopolaires, Bulletin de la Direction des Etudes et Recherches d’E.d.F., Série no. 1 (1969) 53

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1978 Springer Science+Business Media New York

About this chapter

Cite this chapter

Dubanton, C. (1978). Initial Transient Recovery Voltage. In: Ragaller, K. (eds) Current Interruption in High-Voltage Networks. Earlier Brown Boveri Symposia. Springer, Boston, MA. https://doi.org/10.1007/978-1-4757-1685-6_7

Download citation

  • DOI: https://doi.org/10.1007/978-1-4757-1685-6_7

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4757-1687-0

  • Online ISBN: 978-1-4757-1685-6

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics