Advertisement

Oxygen Partial Pressure Distribution Within Skeletal Muscle: Indicator of Whole Body Oxygen Delivery in Patients?

  • P. Boekstegers
  • R. Riessen
  • W. Seyde
Part of the Advances in Experimental Medicine and Biology book series (AEMB, volume 277)

Abstract

The oxygen supply of body organs is clinically estimated by parameters of whole body oxygen transport and hemodynamics. However, the oxygen delivery to a certain organ is not necessarily indicated by changes in these parameters. Even if cardiac output is measured by Swan Ganz thermodilution technique, thus allowing calculation of the whole body oxygen delivery, its distribution to different organs is unknown and might change, particularly in peripheral organs (e.g. in shock, by administration of vasoactive drugs) (Abrams 1985, Feltes et al. 1987, Slater et al. 1973). Therefore, clinically applicable devices for measurement of the distribution of oxygen partial pressure within peripheral organs have been developed (Kessler and Lübbers 1966, Ehrly 1987, Weiss and Fleckenstein 1986) with the aim to determine the state of oxygen supply more directly.

Keywords

Cardiac Output Cardiac Index Oxygen Partial Pressure Oxygen Delivery Paired Data 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Abrams J, 1985, Hemodynamic effects of nitroglycerin and long acting nitrates, Am Heart J. 110: 216–224.PubMedGoogle Scholar
  2. Berk JL, Sampliner JE, 1982, Handbook of Critical Care, Little, Brown and Company, Boston.Google Scholar
  3. Boekstegers P, Weiss M, 1989, Tissue oxygen partial pressure distribution within the human skeletal muscle during hypercapnia, Adv Exp Med Biol, (in press).Google Scholar
  4. Ehrly AM, Hauss J, Huch R, 1987, Clinical oxygen pressure measurement, Springer, Berlin Heidelberg New York.CrossRefGoogle Scholar
  5. Feltes TF, Hansen TN, Martin CG, Leblanc AL, Smith S, Glesler ME, 1987, The effects of dopamine infusion on regional blood flow in newborn lambs, Pediatr Res. 21: 131–136.PubMedCrossRefGoogle Scholar
  6. Ganz, W, Swan HJC, 1972, Measurement of of blood flow by thermodiiution, Am J Cardiol. 29: 241–245.PubMedCrossRefGoogle Scholar
  7. Kessler M, Lübbers DW, 1966, Aufbau und Anwendungsmöglichkeiten verschiedener Po2-Elektroden, Pflügers Arch. 291: 88–94.Google Scholar
  8. Niinikoski J, Laaksonen V, Meretoja O, Jalonen J, Inberg MK, 1980, Oxygen transport to tissue under normovolemic moderate and extreme hemodilution during coronary bypass operation, Ann Thorac Surg. 31: 134–143.CrossRefGoogle Scholar
  9. Slater, GI, Vladeck BC, Bassin R, Kark AE, Shoemaker WC, 1973, Sequential changes in distribution of cardiac output in hemorrhagic shock, Surgery. 73: 714–722.PubMedGoogle Scholar
  10. Tarnow J, 1982, Swan-Ganz catheterization — application, interpretation and complications, Thorac Cardiovasc Surg. 30: 130–136.PubMedCrossRefGoogle Scholar
  11. Weiss CH, Fleckenstein W, 1986, Local tissue Po2 measured with “thick” needle probes, Funktionsanalyse biologischer Systeme. 15: 155–166.Google Scholar

Copyright information

© Plenum Press, New York 1990

Authors and Affiliations

  • P. Boekstegers
    • 1
  • R. Riessen
    • 1
  • W. Seyde
    • 2
  1. 1.Department of PhysiologyMed. Univ. LübeckGermany
  2. 2.Department of AnesthesiologyUniv. GöttingenGermany

Personalised recommendations