Detectors for High Photon Rates

  • V. Radeka
  • J. Fischer
  • J. A. Harder
  • G. C. Smith
Part of the Basic Life Sciences book series (BLSC, volume 51)

Abstract

The increasing flux of photons available from synchrotron radiation sources requires x-ray detectors with greater and greater range in the counting rate capability. Dynamic studies of biological systems in which structural changes can be observed on a short time scale are of particular interest. No detector at present comes close to satisfying all the requirements simultaneously, such as counting rate capability, large dynamic range, high quantum efficiency over a wide range of energies, high position resolution, fast gating and consecutive time-slicing capability. Each detection principle developed so far has some good properties and some serious limitations, and the only practical approach for the near future is to find the best compromise for a particular experiment of interest. For example, some interesting detectors have a sufficiently large number of position elements (pixels) and can operate at high counting rates, but have a limited dynamic range and a long readout time. Thus consecutive time-slicing is not possible, and repetitive excitation and exposures of the sample are necessary.

Keywords

Time Slice Delay Line High Counting Rate Anode Wire Wire Spacing 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Beuttenmuller, R., Kraner, H. W., Ludlam, T. W., Polychronakos, V. A., van Díjk, J., Radeka, V., Chesi, E., Piuz, F., Tschulik, A., and M. J. Esten, 1986, The development and testing of a silicon trigger detector with 400 elements for the HELIOS (NA34) experiment, IEEE Trans. Nucl. Sci., NS-33, No. 2, 1045.Google Scholar
  2. Boíe, R. A., Fischer, J., Inagaki, Y., Merritt, F. C., Radeka, V., Rogers, L. C., and Xí, D. M., 1982, High resolution x-ray gas proportional detectors with delay line position sensing for high counting rates, Nucl. Instr. and Meth., 201: 93.CrossRefGoogle Scholar
  3. Christophorou, L. G., Maxey, D. V., McCorkle, D. L., and Carter, J. G., 1980, Xe-containing fast gas mixtures for gas-filled detectors, Nucl. Instr. and Meth., 171: 491.CrossRefGoogle Scholar
  4. Debbe, R. (personal communication).Google Scholar
  5. Fischer, J., Hrísoho, A., Radeka, V., and Rehak, P., 1985, Proportional chambers for very high counting rates based on gas mixtures of CF4 with hydrocarbons, Nucl. Instr. and Meth., A238: 249.CrossRefGoogle Scholar
  6. Harder, J., 1988, A fast time-to-digital converter for position-sensitive radiation detectors with delay line readouts, Nucl. Instr. and Meth., A265: 500.CrossRefGoogle Scholar
  7. Kammer, J., 1984, Improvement of detector fabrication by the planar process, Nucl. Instr. and Meth., 226: 89.CrossRefGoogle Scholar
  8. Kraner, H. W., (personal communication).Google Scholar
  9. Smith, G. C., Fischer, J., and Radeka, V., 1985, Developments in gas detectors for synchrotron x-ray radiation, Trans. Am. Cryst. Assoc., 21: 41.Google Scholar

Copyright information

© Plenum Press, New York 1989

Authors and Affiliations

  • V. Radeka
    • 1
  • J. Fischer
    • 1
  • J. A. Harder
    • 1
  • G. C. Smith
    • 1
  1. 1.Instrumentation DivisionBrookhaven National LaboratoryUptonUSA

Personalised recommendations