Abstract

Appliances would be more energy efficient if thermal insulations could be developed with apparent thermal conductivity (λ) below 0.01 W/m·K. In an effort to identify candidate materials, λ was measured from 300 to 335 K for unevacuated and evacuated systems of angstrom- and micron-size particles.

Keywords

Fumed Silica Insulation System Solid Conduction Cabot Corporation Effective Pore Size 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    W. T. Lawrence and F. E. Ruccia, “Development of Advanced Insulation for Appliances Task 1,” 0RNL/Sub-81-13800/1 (June 1981).Google Scholar
  2. 2.
    G. L. Copeland, D. L. McElroy, H. A. Fine and T. W. Tong, “Development of Advanced Insulation for Appliances,” ORNL/TM-9121 (June 1984).Google Scholar
  3. 3.
    P. Pellaux-Gervais and D. Goumy, “Insulating Material with Low Thermal Conductivity, Formed of a Compacted Granular Structure,” United States Patent 4,159,359 assigned to L’Air Liquide, Paris, France, June 26, 1979.Google Scholar
  4. 4.
    Private communication from H. Cochrane, Cabot Research Center, Tuscola, Illnois to D. L. McElroy, ORNL, January 1983.Google Scholar
  5. 5.
    Private communication from S. Spinney, Dynatech R/D Company, to E. Wagner, Cabot Corporation, September 5, 1975 (Cab-0-Sil M-5).Google Scholar
  6. 6.
    Private communication from M. Fulk, National Bureau of Standards to H. Cochrane, Cabot Corporation, February 20, 1958 (Cab-0-Sil M-5).Google Scholar
  7. 7.
    Degussa Brochure dated July 2, 1950 on Aer-O-Sil 200.Google Scholar
  8. 8.
    P. E. Glazier, U.S. Patent No. 3,151,365 issued October 6, 1964 (Cab-O-Sil M-5).Google Scholar
  9. 9.
    Mink 1300 and 2000, Manvilie Corporation, P. O. Box 5108, Denver, Colorado 80217.Google Scholar
  10. 10.
    Microtherm20CR, Micropore International, LTD., Droitwich, Wors., WR97DJ, England.Google Scholar
  11. 11.
    H. Reiss, “An Evacuated Powder Insulation for a High Temperature Na/S-Battery,” AIAA-81-1107, AIAA 16th Thermophysics Conference, Palo Alto, CA (June 1981).Google Scholar
  12. 12.
    D. L. McElroy, R. S. Graves, D. W. Yarbrough and J. P. Moore, “A Flat Insulation Tester that Uses an Unguarded Nichrome Screen Wire Heater,” in Forum on the Guarded Hot Plate and Heat Flow Meter State-of-the-Art, Quebec, Canada (October 7–8, 1982 )Google Scholar
  13. 13.
    R. S. Graves, D. W. Yarbrough and D. L. McElroy, “Apparent Thermal Conductivity Measurements by an Unguarded Technique,” in Thermal Conductivity 18, T. Ashworth, ed., Plenum Press, New York (in press).Google Scholar
  14. 14.
    Private communication from O. D. Erlandson, General Atomic Company, San Diego, CA to R. Roberts, Union Carbide Corporation Nuclear Division, Oak Ridge, TN, March 17, 1980.Google Scholar
  15. 15.
    Cabot Corporation Bulletin, “Cab-O-Sil Properties and Functions,” Headquarters: 125 High Street, Boston, MA 02110.Google Scholar
  16. 16.
    Degussa, Inc., Pigments Division, Route 46 at Hollister Road, Teterboro, NJ 07608.Google Scholar
  17. 17.
    J. P. Moore, R. J. Dippenaar, R. O. A. Halland D. L. McElroy, “Thermal Conductivity of Powders with U02 or Th02 Microspheres in Various Gases from 300 to 1300 K,” ORNL/TM-8196 (June 1982).Google Scholar

Copyright information

© Purdue Research Foundation 1985

Authors and Affiliations

  • G. L. Copeland
    • 1
  • D. L. McElroy
    • 1
  • R. S. Graves
    • 1
  • F. J. Weaver
    • 1
  • H. A. Fine
    • 2
  • T. W. Tong
    • 2
  1. 1.Martin Marietta Energy Systems, Inc. Metals and Ceramics DivisionOak Ridge National LaboratoryOak RidgeUSA
  2. 2.Department of Metallurgical Engineering and Mechanical EngineeringUniversity of KentuckyLexingtonUSA

Personalised recommendations