Analysis and Simulation of the DOEL-2 Steam Generator Tube Rupture Event

  • E. J. Stubbe
  • J. M. Chalant
  • H. Michiels
  • H. Sablon

Abstract

Severe plant transients, following a steam generator tube rupture (SGTR), have a relatively high probability of occurrence and may entrain a certain risk to the population and the plant (class IV accident). The SGTR event which occurred at the DOEL-2 plant in June 1979, presents many interesting phenomena which are analysed based on the on-site data recordings on one hand, and a detailed numerical simulation, using the RELAP-5 code, on the other hand. This event stimulated a revision of the emergency procedures, led to considerable improvements in the operator control over safeguard systems and highlights the importance of operator training. The numerical results do enhance the understanding of the observed phenomena and complement the plant recorded data. The RELAP-5 code is capable of simulating such transient.

Keywords

Steam Generator Charge Pump Condense Heat Transfer Safety Injection Pressurizer Spray 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Analysis of steam generator tube rupture events at OCONEE and GINNA, INPO 82-030, November 1982.Google Scholar
  2. 2.
    RELAP-5 MOD 1 Code Manual V.H. RANSOM et al. NUREG/CR-1826, EGG-2070, November 1980.Google Scholar