Skip to main content

Rapid High-Performance Liquid Chromatographic Method for the Measurement of Temazepam in Blood-Plasma or Serum

  • Chapter
Forensic Toxicology

Summary

A simple high-performance liquid chromatographic method has been developed for the measurement of temazepam in small (200 μl) volumes of plasma or serum. After addition of 0.02 mol/1 Tris buffer, pH 7.4 (50 μl) containing an internal standard, the sample is vortex mixed with diisopropyl ether (200 μl) for 30 sec. and centrifuged at 9950.g for 3 min. A portion (100 μl) of the resulting extract is analysed on a microparticulate (5 μ) silica column using methanol:diethyl ether (75:25) containing perchloric acid (0.025% v/v) as the mobile phase, and the absorption of the column effluent is monitored at 240 nm. No endogenous sources of interference have been observed. The limit of sensitivity of the assay is 0.02 mg/1, and the method is applicable to the simultaneous assay of some other benzodiazepines.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • Belvedere, G., Tognoni, G., Frigerio, A. and Morselli, P.L. (1972), Anal. Lett., 5, 531

    Article  Google Scholar 

  • Flanagan, R.J. and Berry, D.J. (1977), J. Chromatogr., 131, 131

    Article  Google Scholar 

  • Kabra, P.M., Stevens, G.L. and Marton, L.J. (1978), J. Chromatogr., 150, 355

    Article  Google Scholar 

  • Vree, T.R., Baars, A.M., Hekster, Y.A., van der Kleijn, E. and O’Reilly, W.J. (1979), J. Chromatogr., 162, 605

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1980 International Association of Forensic Toxicologists

About this chapter

Cite this chapter

Huggett, A., Storey, G.C.A., Flanagan, R.J. (1980). Rapid High-Performance Liquid Chromatographic Method for the Measurement of Temazepam in Blood-Plasma or Serum. In: Oliver, J.S. (eds) Forensic Toxicology. Springer, Boston, MA. https://doi.org/10.1007/978-1-4684-1478-3_30

Download citation

  • DOI: https://doi.org/10.1007/978-1-4684-1478-3_30

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4684-1480-6

  • Online ISBN: 978-1-4684-1478-3

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics