Abstract
Critical heat fluxes (CHFs) were measured on single same sized flat plate heaters located at one end of six rectangular ducts with different cross-sectional areas in subcooled He II for bulk liquid temperature range of 1.8 to 2.1 K at atmospheric pressure in order to clarify the heat flow in a He II contained duct with a sudden change in its cross-sectional area. One side of the test plate was attached to the end plate of the duct made of Fiber-Reinforced Plastics (FRP), and the other end of the duct was opened to pressurized He II. The ratio of the cross-sectional duct area to the heater area was varied from 1.0 to 3.5. The CHFs increased with the increase in the ratio and approached a constant value: the CHF on the same sized flat plate in a pool of He II without duct. A CHF correlation can express the experimental data within 20 % error.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
J.M. Pfotenhauer, Geometry Dependent of Steady State Heat Transfer in He II, Cryogenics. 32:466(1992)
M. Shiotsu, K. Hata and A. Sakurai, Effect of Test Heater Diameter on Critical Heat Flux in He II, “Advances in Cryogenic Engineering,” Vol.39, Plemum Press, New York (1994), p. 1797.
H. Tatsumoto, K. Hata, K. Hama Y. Shirai and M. Shiotsu, Critical Heat Fluxes on Flat Plates in Pressurized He II, “Proc. of 17th International Cryogenic Engineering Conference”, IPC Science and Technology Press, Guildford (1998), p. 683
M. Shiotsu, K. Hata, and A. Sakurai, Transient Heat Transfer from a Horizontal wire in Superfluid Helium Caused by Exponential and Step Heat Inputs. “Superfluid Helium Heat Transfer,” J.P. Kelly and W.J. Schneider, ed., ASME Publication No. HTD 134(1990), p. 9.
A. Sakurai, M. Shiotsu and K. Hata, Transient Heat Transfer for Large stepwise Heat Inputs to a Horizontal Wire in Saturated He II, “Advances in Cryogenic Engineering,” Vol. 37A, Plenum Press, New York (1992), p. 25.
M. Shiotsu, K. Hata and A. Sakurai, Steady and Unsteady Heat Transfer from a Horizontal Wire in a Pool of Subcooled He II, “Heat Transfer and Superconducting Magnet Energy Storage,” ASME Publication No. HTD-221(1992), p. 19.
M. Shiotsu, K. Hata and A. Sakurai, Transient Heat Transfer from a Horizontal Wire in Subcooled He II at Atmospheric Pressure for a Wide Range of Wire Diameter, “Advances in Cryogenic Engineering,” Vol.41A(1992), p. 241.
K. Hata, M. Shiotsu, Y. Takeuchi and K. Hama, A Model for the CHF of One-wall Heated Rectangular He II Channel, “Proc. of 17th International Cryogenic Engineering Conference”, IPC Science and Technology Press, Guildford (1998), p. 789
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2000 Springer Science+Business Media New York
About this chapter
Cite this chapter
Tatsumoto, H., Hata, K., Hama, K., Shirai, Y., Shiotsu, M. (2000). Critical Heat Fluxes on a Flat Plate Attached to One End of a Rectangular Duct Containing Pressurized He II. In: Shu, QS. (eds) Advances in Cryogenic Engineering. Advances in Cryogenic Engineering. Springer, Boston, MA. https://doi.org/10.1007/978-1-4615-4215-5_15
Download citation
DOI: https://doi.org/10.1007/978-1-4615-4215-5_15
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4613-6892-2
Online ISBN: 978-1-4615-4215-5
eBook Packages: Springer Book Archive