Abstract
The Brookhaven Medical Research Reactor (BMRR)1 became operational in 1959 to support Boron Neutron Capture Therapy (BNCT) research in the Medical Department of the Brookhaven National Laboratory (BNL). The research was interrupted in 1961 after the failure of initial BNCT trials to show efficacy.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
J. B. Godel, “Description of Facilities and Mechanical Components, Medical Research Reactor (MRR)”, BNL 600 (T-173), Brookhaven National Laboratory, Feb. 1960.
T. J. Less, R. M. Brugger, “Reactor Moderated Intermediate Energy Neutron Beams for Neutron Capture Therapy”, Strahlentherapie und Onkologie, Feb./March 1989.
F. J. Wheeler, D. K. Parsons, D. W. Nigg, D. E. Wessol, L. G. Miller, and R. G. Fairchild, “Physics Design for the Brookhaven Medical Research Reactor Epithermal Neutron Source”, Neutron Beam Design. Development and Performance for Neutron Capture Therapy, O. Harling and R. Zamenhoff, eds. Mar. 1989, Plenum Press, New York, 1990.
Y. D. Harker, R. A. Anderl, G. K. Becker, and L. G. Miller, “Spectral Characterization of the Epithermal Neutron Beam at the Brookhaven Medical Research Reactor”, Journal of Nuclear Science and Engineering, Vol. 110, 1992.
S. K. Saraf, J. Kalef-Ezra, R. G. Fairchild, B. H. Laster, S. Fiarman, E. Ramsey,“ Epithermal Beam Development at the BMRR: Dosimetric Evaluation,” Neutron Beam Design. Development, and Performance for Neutron Capture Therapy, O. Harling and R. Zamenhof, eds., Mar. 1989, Plenum Press, New York, 1990.
H. B. Liu, “ Isodose Curves and Treatment Planning for Boron Neutron Capture Therapy,” Dissertation in Nuclear Engineering Program of University of Missouri-Columbia, Aug. 1992.
Y. D. Harker, C. R. Omevo, P. D. Randolph, and F. J. Wheeler, “Neutron Measurements in Canine and Cylindrical Phantoms at the Brookhaven Medical Research Reactor and the High-Flux Reactor (Petten)”, Journal of Nuclear Science and Engineering, Vol. 110, 1992.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1993 Springer Science+Business Media New York
About this chapter
Cite this chapter
Liu, H.B., Brugger, R.M., Rorer, D.C. (1993). Enhancement of the Epithermal Neutron Beam at the Brookhaven Medical Research Reactor. In: Soloway, A.H., Barth, R.F., Carpenter, D.E. (eds) Advances in Neutron Capture Therapy. Springer, Boston, MA. https://doi.org/10.1007/978-1-4615-2978-1_15
Download citation
DOI: https://doi.org/10.1007/978-1-4615-2978-1_15
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4613-6296-8
Online ISBN: 978-1-4615-2978-1
eBook Packages: Springer Book Archive