Front-to-Total Ratio as a Function of Polar Pattern

  • John M. Eargle

Abstract

The front-hemisphere random energy efficiency (REF) is given by the following equation:
$$REF = 0.5 - 0.5B + 0.167{{B}^{2}} $$
(77.1)

Keywords

Acoustics 

References

  1. Bauer (1940)Google Scholar
  2. Glover (1940)Google Scholar
  3. Woram (1989)Google Scholar

Copyright information

© Springer Science+Business Media New York 1994

Authors and Affiliations

  • John M. Eargle

There are no affiliations available