Skip to main content

A Comparison of Algorithms for the Detection of Stenotic Vessels

  • Chapter
  • 407 Accesses

Part of the book series: Acoustical Imaging ((ACIM,volume 21))

Abstract

In order to develop a senSItive detection scheme for minor stenoses, the received acoustic signal from regions within a stenosis and distal to a stenosis has been modeled and evaluated using experimental data. In comparison with a parabolic profile, analysis of the signal returned from vessel regions distal to the stenosis has shown that the correlated signal interval increases near the vessel wall and decreases in the center of the vessel.[l] With the goal of spatially mapping these changes to locate the source of the flow disturbance, two indicators of the correlated signal interval are presented and evaluated for known experimental flow conditions. The first parameter is the normalized likelihood function, evaluated at the maximum likelihood velocity, with coherent summation over a sequence of 8 ultrasonic pulses. The second parameter is the magnitude of the correlation at a lag of one pulse interval divided by the signal power. The experimental results show that the use of a parameter which coherently sums the signal correlation over a set of sequential pulses and lag values provides a sensitive indication of changes in a flow profile, and may be used to develop a spatial map of the flow conditions. This analysis differs from previous work in the transmission of a train of short, wideband pulses, and the resulting increased spatial resolution of the parameters.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. K.W. Ferrara and V.R. Algazi. “A Theoretical and Experimental Analysis of the Received Signal From Disturbed Blood Flow,” IEEE Transactions on Ultrasonics. Ferroelectrics and Frequency Control March 1994.

    Google Scholar 

  2. K.W. Ferrara and V.R. Algazi. “A New Wideband Spread Target Maximum Likelihood Estimator For Blood Velocity Estimation Part One-Theory,” IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control January 1991, 1–16.

    Google Scholar 

  3. K.W. Ferrara and V.R. Algazi. MA Statistical Analysis of the Received Signal from Blood During Laminar Flow,“ IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. March 1994.

    Google Scholar 

  4. C. Kasai, K. Namekawa, A. Koyano, and R. Omoto, “Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique,” IEEE Transactions on Sonics and Ultrasonics. Vol. SU-32, No. 3, May 1985.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1995 Springer Science+Business Media New York

About this chapter

Cite this chapter

Ferrara, K. (1995). A Comparison of Algorithms for the Detection of Stenotic Vessels. In: Jones, J.P. (eds) Acoustical Imaging. Acoustical Imaging, vol 21. Springer, Boston, MA. https://doi.org/10.1007/978-1-4615-1943-0_43

Download citation

  • DOI: https://doi.org/10.1007/978-1-4615-1943-0_43

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4613-5797-1

  • Online ISBN: 978-1-4615-1943-0

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics