Skip to main content

VESIMA-MED

Energy and Data Transmission

  • Chapter
Telemedicine

Abstract

This paper presents a micro-movement long-term monitoring system optimising the healing process of fractures. It focus in particular on the energy and data transmission path of the system. Continuous and accurate monitoring near the fracture zone of bones requires an implantable and low power consumption device. Additionally, the implant needs to be small in size. To serve as a long-term implant, no batteries are used due to their limitations in lifetime and power. Thus, the system is inductively powered based on the inductive coupling between an external and an internal coil. Monitoring is done by a miniature, capacitive accelerometer. Using a telemetric link the measured data stream is transmitted from the implant to a microcontroller, where the data is analysed.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Goodship, A. E., and Kenwright, J., 1985, The influence of induced micromovement upon the healing of experimental tibial fractures. J Bone Joint Surg [Br], 67(4), 650–655

    Google Scholar 

  2. Clasbrummel, B., Muhr, G., and Goodship, A. E., 1997, Zeitabhängige mechanisch Stimulation in der enchondralen Frakturheilung beim Schaf. Biomed. Tech. Band 42, 521–522

    Google Scholar 

  3. O. Lüdtke, V. Biefeld, A.Buhrdorf, J. Binder, October 1999, Laterally driven accelerometer fabricated in single crystalline silicon, in Sensors and Actuators A 82, p. 149 -154,

    Article  Google Scholar 

  4. M. Degrauwe and e.Vittoz, June 1985, A Micropower CMOS-Instrumentation Amplifier in IEEE J. Solid State Circuits, vol. sc-20, no. 3,

    Google Scholar 

  5. M. Banu and J.M. Khoury, December 1988, Fully differential operational amplifiers with accurate output balancing, IEEE J. Solid State Circuits, vol. 23, no. 6,

    Google Scholar 

  6. Steven R. Norsworthy, R. Schreier, Gabor C. Temes, USA1997, Delta-Sigma Data Converters Theory, Design, and Simulation, IEEE Press.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2001 Springer Science+Business Media New York

About this chapter

Cite this chapter

Prämaßing, F., Schmidt, M., Biefeld, V., Binder, J., Clasbrummel, B., Jettkant, B. (2001). VESIMA-MED. In: Buzug, T.M., Handels, H., Holz, D. (eds) Telemedicine. Springer, Boston, MA. https://doi.org/10.1007/978-1-4615-1253-0_17

Download citation

  • DOI: https://doi.org/10.1007/978-1-4615-1253-0_17

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4613-5463-5

  • Online ISBN: 978-1-4615-1253-0

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics