Abstract
There is no doubt that the laser technology is being applied to a vast number of procedures, many of which have clear advantages over the other methods. Regardless of the kind of medical applications; lasers safety to the patient and administering staff against any harmful exposure or effects that may arise in the use and handling of lasers is an important consideration. The goal of this chapter is to present information that will assist all parties involved to work in a safe manner. Throughout the chapter, and particularly at the end of this chapter, a number of laser accidents in the medical field will be presented. It is hoped that the reader will see a comparison to one’s own experiences and take corrective steps.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Nezhat C, Winer W, Nezhat F et. al.: Smoke from Laser Surgery: Is there a hazard? “Lasers in Surgery and Medicine” 1987; 7: 376–382.
Fisher RW: Laser smoke in the operating room, “Biomedical Technology Today” 1987; 191–194.
Garden JM, O’Banion KM, Shelnitz LS et. al.: Papillomavirus in the vapor of carbon dioxide laser-treated verrucae, “Journal of American Medical Association,” 1988;259: 1199–1202.
Resource Material
Web Pages CDRH Home page http://wwwfda.gov/cdrh/index.html Control of Smoke from Laser/Electric Surgical Procedures http://www.cdc.gov/niosh/hc11.html? MAUDE Database Accidents http://www.accessckta.fda.gov/scripts/cdrh/ctdocs/cfMAUDE/Detail.CFM?MDREOI_ID=17985&CRIT=Excimer%20Laser OSHA Laser Safety http://www.osha-slc.gov/SLTC/laserhazards/index.html Medical Device Reporting search pagehttp://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfmdr/search.CFM
Books A.R.Henderson, A Guide to Laser Safety, Chapman & Hall1997 K.A. Ball, Lasers The perioperative Challenge, 1995 Mosby Press LIA Guide to Medical Laser Safety, LIA Press 1997 Guidelines for Laser Safety and Hazard Assessment. OSHA Instruction PUB 8 1.7(1991 August 5), 70 pages.
Standards ANSI Z87.1–1989: Practice for Occupational and Educational Eye and Face Protection. ANSI Z136.1–2000 American National Standard for the Safe Use of Lasers. ANSI Z136.3–1996: American National Standard for the Safe Use of Lasers in the Health Care Environment. ANSI/NFPA 70–1996: The National Electrical Code. NFPA Code #115 Laser Safety
Valued Miscellaneous Sources Boswell Eye Institute, Scottsdale Az. Laser Safety in Surgery and Medicine, Rockwell Laser Industries Massachusetts Institute of Technology Lincoln Laboratory Duke University Medical Center
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2002 Springer Science+Business Media New York
About this chapter
Cite this chapter
Barat, K. (2002). Laser Safety in Medicine. In: Vij, D.R., Mahesh, K. (eds) Medical Applications of Lasers. Springer, Boston, MA. https://doi.org/10.1007/978-1-4615-0929-5_11
Download citation
DOI: https://doi.org/10.1007/978-1-4615-0929-5_11
Publisher Name: Springer, Boston, MA
Print ISBN: 978-0-7923-7662-0
Online ISBN: 978-1-4615-0929-5
eBook Packages: Springer Book Archive