Skip to main content

Robot-Assisted Neck Dissection in Papillary Thyroid Carcinoma

  • Chapter
  • First Online:
Minimally Invasive and Robotic Thyroid and Parathyroid Surgery

Abstract

Traditionally, total thyroidectomy was performed through an open transcervical incision and in cases where there was evident nodal metastasis, the conventional surgical method was to make an extended single transverse incision or any other long transcervical incisions to complete the required neck dissection. Recently, there have been many efforts towards thyroidectomy in order to decrease the patient’s burden. Minimally invasive surgical techniques have been developed and applied by many institutions worldwide, and more recently, various techniques of remote access surgery have been suggested and actively applied. Since the advent of robotic surgical systems, some have adopted the concept of remote access surgery into developing various robotic thyroidectomy techniques. The more former and widely acknowledged robotic thyroidectomy technique uses a transaxillary (TA) approach which has been developed by Chung et al. in Korea. Terris et al. realized some shortcomings of robotic TA thyroidectomy especially in their patients in the United States and developed and reported the feasibility of robotic facelift thyroidectomy. In cases of thyroid carcinomas with lateral neck node metastases, Chung et al. have attempted to perform concomitant modified radical neck dissection (MRND) after robotic thyroidectomy through the same TA port. This type of robot-assisted neck dissection (RAND), however, had some inherent limitations due to fact that lymph nodes of the upper neck were difficult to remove.

Recently, our group devised a modified approach called the transaxillary and retroauricular (TARA) approach, which was shown to be feasible for the upper neck dissection. With the accumulation of experience with the TARA approach, we realized that the retroauricular (RA) or modified facelift (MFL) approach is sufficient for RAND in HNC. Based on our surgical experiences, we could eventually adopt this particular technique to robotic total thyroidectomy and also MRND where needed. However, the long-term outcomes of RAND via TARA or RA approach should be further assessed to determine its oncologic safety.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 139.00
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Recommended Reading

  • Kang SW, Lee SC, Lee SH, et al. Robotic thyroid surgery using a gasless, transaxillary approach and the da Vinci S system: the operative outcomes of 338 consecutive patients. Surgery. 2009;146:1048–55.

    Article  PubMed  Google Scholar 

  • Kang SW, Lee SH, Ryu HR, et al. Initial experience with robot-assisted modified radical neck dissection for the management of thyroid carcinoma with lateral neck node metastasis. Surgery. 2010;148:1214–21.

    Article  PubMed  Google Scholar 

  • Kim WS, Lee HS, Kang SM, et al. Feasibility of robot-assisted neck dissections via a transaxillary and retroauricular (“TARA”) approach in head and neck cancer: preliminary results. Ann Surg Oncol. 2012;19:1009–17.

    Article  PubMed  Google Scholar 

  • Kim CH, Koh YW, Kim D, Chang JW, Choi EC, Shin YS. Robotic-assisted neck dissection in submandibular gland cancer: preliminary report. J Oral Maxillofac Surg. 2013;71(8):1450–57.

    Google Scholar 

  • Kim CH, Chang JW, Choi EC, Shin YS, Koh YW. Robotically assisted selective neck dissection in parotid gland cancer: preliminary report. Laryngoscope. 2013b;123(3):646–50.

    Article  PubMed  Google Scholar 

  • Kupferman ME, Patterson M, Mandel SJ, et al. Patterns of lateral neck metastasis in papillary thyroid carcinoma. Arch Otolaryngol Head Neck Surg. 2004;130:857–60.

    Article  PubMed  Google Scholar 

  • Lee S, Ryu HR, Park JH, et al. Excellence in robotic thyroid surgery: a comparative study of robot-assisted versus conventional endoscopic thyroidectomy in papillary thyroid microcarcinoma patients. Ann Surg. 2011;253:1060–6.

    Article  PubMed  Google Scholar 

  • Lee HS, Kim WS, Hong HJ, Ban MJ, Lee D, Koh YW, Choi EC. Robot-assisted supraomohyoid neck dissection via a modified face-lift or retroauricular approach in early-stage cN0 squamous cell carcinoma of the oral cavity: a comparative study with conventional technique. Ann Surg Oncol. 2012;19(12):3871–8.

    Article  PubMed  Google Scholar 

  • Lewis Jr JS, Carpenter DH, Thorstad WL, Zhang Q, Haughey BH. Extracapsular extension is a poor predictor of disease recurrence in surgically treated oropharyngeal squamous cell carcinoma. Mod Pathol. 2011;24:1413–20.

    Article  PubMed  Google Scholar 

  • Park YM, Holsinger FC, Kim WS, Park SC, Lee EJ, Choi EC, Koh YW. Robot-assisted selective neck dissection of levels II to V via a modified facelift or retroauricular approach. Otolaryngol Head Neck Surg. 2013;148(5):778–85.

    Article  PubMed  Google Scholar 

  • Roh J, Kim J, Park CI. Lateral cervical lymph node metastases from papillary thyroid carcinoma: pattern of nodal metastases and optimal strategy for neck dissection. Ann Surg Oncol. 2008;15:1177–82.

    Article  PubMed  Google Scholar 

  • Shaha AR, Shah JP, Loree TR. Patterns of nodal and distant metastasis based on histologic varieties in differentiated carcinoma of the thyroid. Am J Surg. 1996;172:692–4.

    Article  CAS  PubMed  Google Scholar 

  • Shin YS, Hong HJ, Koh YW, et al. Gasless transaxillary robot-assisted neck dissection: a preclinical feasibility study in four cadavers. Yonsei Med J. 2012;53:193–7.

    Article  PubMed Central  PubMed  Google Scholar 

  • Singer MC, Seybt MW, Terris DJ. Robotic facelift thyroidectomy: I. Preclinical simulation and morphometric assessment. Laryngoscope. 2011;121:1631–5.

    Article  PubMed  Google Scholar 

  • Terris DJ, Singer MC. Qualitative and quantitative differences between 2 robotic thyroidectomy techniques. Otolaryngol Head Neck Surg. 2012a;147:20–5.

    Article  PubMed  Google Scholar 

  • Terris DJ, Singer MC. Robotic facelift thyroidectomy: facilitating remote access surgery. Head Neck. 2012b;34:746–7.

    Article  PubMed  Google Scholar 

  • Terris DJ, Singer MC, Seybt MW. Robotic facelift thyroidectomy: II. Clinical feasibility and safety. Laryngoscope. 2011a;121:1636–41.

    Article  PubMed  Google Scholar 

  • Terris DJ, Singer MC, Seybt MW. Robotic facelift thyroidectomy: patient selection and technical considerations. Surg Laparosc Endosc Percutan Tech. 2011b;21:237–42.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yoon Woo Koh MD, PhD .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer Science+Business Media New York

About this chapter

Cite this chapter

Koh, Y.W., Choi, E.C. (2014). Robot-Assisted Neck Dissection in Papillary Thyroid Carcinoma. In: Terris, D., Singer, M. (eds) Minimally Invasive and Robotic Thyroid and Parathyroid Surgery. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-9011-1_13

Download citation

  • DOI: https://doi.org/10.1007/978-1-4614-9011-1_13

  • Published:

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-1-4614-9010-4

  • Online ISBN: 978-1-4614-9011-1

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics