Implantable Cardioverter-Defibrillators

  • David Korpas
Chapter

Abstract

An implantable cardioverter defibrillator (ICD) is an active implantable medical device primarily used to deliver a high-energy electric shock to the heart via intracardial leads. The electric shock causes concurrent depolarization of all cell membranes in myocardial volume followed by an absolute refractory period. As a result, a tachycardia impulse spreading in the myocardium is interrupted. This implantable device also works as a pacemaker and applies antitachycardia pacing (ATP) to terminate ventricular tachycardia (VT) when high-energy shocks are not required.

Keywords

Ventricular Tachycardia Implantable Cardioverter Defibrillator Supraventricular Tachycardia Detection Zone Coupling Interval 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

References

  1. 70.
    Teligen 100 system guide. Boston Scientific, St. Paul. © 2009, 283 pGoogle Scholar
  2. 71.
    Bernstein A, Camm AJ, Fletcher RD et al (1993) North American society of pacing and electrophysiology policy statement. The NASPE/BPEG defibrillator code. Pacing Clin Electrophysiol 16(9):1776–1780PubMedCrossRefGoogle Scholar
  3. 72.
    International Organization for Standardization (2010) ISO 14708-6:2010: Implants for surgery – active implantable medical devices – part 6: particular requirements for active implantable medical devices intended to treat tachyarrhythmia (including implantable defibrillators), 25 Feb 2010Google Scholar
  4. 73.
    Strydis Ch. Implantable microelectronic devices. M.Sc thesis. http://ce.et.tudelft.nl/publicationfiles/1038_555_thesis_strydis.pdf. Accessed 6 Jan 2011
  5. 74.
    Medtronic Corporation: Maximo DR 7278 – Implant manual. www.medtronic.com/manuals. Accessed 30 Sept 2010
  6. 75.
    See Reference [66]Google Scholar
  7. 76.
    Theuns DAMJ, Rivero-Ayerza M, Goedhart MD, Miltenburg M, Jordaens JL (2008) Morphology discrimination in implantable cardioverter-defibrillators: consistency of template match percentage during atrial tachyarrhythmias at different heart rates. Europace 10:1060–1066PubMedCrossRefGoogle Scholar
  8. 77.
    Medtronic Corporation: Protecta CRT-D D364TRG – Clinician manual (EE). www.medtronic.com/manuals. Accessed 24 Nov 2010
  9. 78.
    Mocanu D et al (2004) Patient-specific computational analysis of transvenous defibrillation: a comparison to clinical metrics in humans. Ann Biomed Eng 32(6):775–783PubMedCrossRefGoogle Scholar
  10. 79.
    Jacob S et al (2010) High defibrillation threshold: the science, signs and solutions. Indian Pacing Electrophysiol J 10(1):21–39PubMedGoogle Scholar
  11. 82.
    System guide Cognis 100-D CRT-D. Boston Scientific, St. Paul, © 2009, 306 pGoogle Scholar

Copyright information

© Springer Science+Business Media New York 2013

Authors and Affiliations

  • David Korpas
    • 1
    • 2
  1. 1.Boston Scientific Czech RepublicPragueCzech Republic
  2. 2.Faculty of Electrical Engineering and Computer Science Department of Cybernetics and Biomedical EngineeringVSB - Technical University of OstravaOstrava-PorubaCzech Republic

Personalised recommendations