Abstract

Tri-axis accelerometers are widely used to detect physical activity. Three-axis accelerometers are sensing devices that measure gravitational changes. In this chapter, a body motion index was derived using an axis accelerometer with additional signal filtering and feature extraction. Various body motion factors, motion rates, motion angles, and directions were examined during an experiment. Six participants were recruited for this study. A TD1A system (K&Y Labs) was employed; this wireless system comprised one electrocardiogram (ECG) and tri-axis acceleration sensor. Using a belt, an amplifier was fixed to each participant in the same relative position between the abdomen and chest for each experimental measurement. The participants were instructed to move in both directions seven times for varying durations and at differing motion angles. Features were extracted from the motion index series. Both the mean and maximum values of the motion index series were used. The results showed that specific posture change patterns had corresponding axis acceleration variations. The influence of the motion angle on the motion index value was considerably greater than that of the motion rate. Higher motion angles were achieved with higher motion index values. Generally, anterior-posterior swaying caused greater motions than left-to-right swaying under the same motion conditions for angle and rate. Therefore, the proposed motion classification algorithm combined with a tri-axis accelerometer has significant potential for motion detection. However, the use of accelerometers has a number of limitations. In the future, a multi-sensor system will be employed to detect body movements.

Keywords

Accelerometer Body motion detection 

Notes

Acknowledgments

This study was partially supported by the National Science Council, Taiwan, under grant number NSC 101-2221-E-468-008.

References

  1. 1.
    Farahmand F, Khadivi K, Rodrigues JJP (2009) Detecting intra-fraction motion in patients undergoing radiation treatment using a low-cost wireless accelerometer. Sensors 9:6715–6729CrossRefGoogle Scholar
  2. 2.
    Betker AL, Moussavi ZM, Szturm T (2008) Ambulatory center of mass prediction using body accelerations and center of foot pressure. IEEE Trans Biomed Eng 55:2491–2498CrossRefGoogle Scholar
  3. 3.
    Bouten CV, Koekkoek KT, Verduin M, Kodde R, Janssen JD (1997) A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity. IEEE Trans Biomed Eng 44:136–147CrossRefGoogle Scholar
  4. 4.
    Chang KM, Liu SH (2011) Wireless portable electrocardiogram and a tri-axis accelerometer implementation and application on sleep activity monitoring. Telemed J e-Health 17:177–184CrossRefGoogle Scholar
  5. 5.
    van Hees VT, Renstrom F, Wright A, Gradmark A, Catt M, Chen KY, Lof M, Bluck L, Pomeroy J, Wareham NJ, Ekelund U, Brage S, Franks PW (2011) Estimation of daily energy expenditure in pregnant and non-pregnant women using a wrist-worn tri-axial accelerometer. PLoS One 6:e22922CrossRefGoogle Scholar

Copyright information

© Springer Science+Business Media New York 2013

Authors and Affiliations

  • Kang-Ming Chang
    • 1
    • 2
  • Sih-Huei Chen
    • 3
  • Chun-Lung Huang
    • 4
  1. 1.Department of Photonics and Communication EngineeringAsia UniversityTaichungTaiwan
  2. 2.Graduate Institute of Clinical Medical ScienceChina Medical UniversityTaichungTaiwan
  3. 3.Department of Computer Science and Information EngineeringAsia UniversityTaichungTaiwan
  4. 4.Department of Mechanical and Automatic EngineeringChung Chou University of Science and TechnologyChanghuaTaiwan

Personalised recommendations