Abstract
Deadbeat control algorithm has good real-time performance and high precision, but it depends heavily on exact circuit system model. This chapter systematically studies the grid-connected current controlled by deadbeat algorithm in single-phase grid-connected inverter in different filter modes such as the single inductance L filter, the second-order LC (inductance and capacitance) filter and the third-order LCL filter. Based on the classical control theory, mathematical models of the inverter system were deduced in deadbeat control under the different filter conditions. And the design idea was described in the chapter. For the problem that resonance easily occurred in LCL filter, which brought difficulty in system design, two resonant rings in the circuit topology were inhibited by improving the structure of capacitance C. The computer simulation results showed that the waveform smoothness of grid current gradually improved with the increase in the number of filter order. At last, in a 3 kw prototype, the related hardware and software design were carried out, and the effectiveness and feasibility of high-order deadbeat control algorithm were verified.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Yang P, Chen N, Liu S (2011) Research on the improved current deadbeat control algorithm of photovoltaic grid-connected inverter. In: Power Electronics Systems and Applications (PESA), 2011 4th International Conference. pp 1–3
Mengchao M, Peng L, Botao L (2008) Study on deadbeat control strategy for grid-connected distributed generation system. In: Electric Utility Deregulation and Restructuring and Power Technologies, 2008. DRPT 2008. Third International Conference. pp 2553–2557
Moreno JC, Huerta JME (2009) A robust predictive current control for three-phase grid-connected inverters. Ind Electron IEEE Trans 56:1993–2004
Kadri R, Gaubert J, Champenois G, Mostefai M (2010) Design of a single-phase grid-connected photovoltaic system based on deadbeat current control with LCL filter. In: Power Electronics and Motion Control Conference (EPE/PEMC), 2010 14th International. pp T3-147–T3-153
Ahmed T, Nishida K, Nakaoka M (2011) Deadbeat current control of LCL-filter for grid connected three-phase voltage source inverter. In: Power Electronics and Drive Systems (PEDS), 2011 I.E. Ninth International Conference. pp 459–467
Ren BY, Sun XD, Tong XQ, Luo XY (2009) The improved deadbeat control strategy of grid-connected inverter. Power Electron Technol 43(8):35–36
Xu ZY, Xu AG, Xie SJ (2009) Double-loop grid-connected current control of grid-connected inverter that uses the LCL filters. Chin J Electr Eng 29(27):36–41
Zhang XP, Lin ZX, Li YX, Xu HH (2007) The new control strategy of PWM rectifier of filtering. Trans Chin Electrotechn Soc 22(2):74–77
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer Science+Business Media New York
About this paper
Cite this paper
Han, G., Min, W., Xia, Y. (2014). Grid-Connected Inverter Control Technology Based on the Deadbeat Algorithm. In: Xing, S., Chen, S., Wei, Z., Xia, J. (eds) Unifying Electrical Engineering and Electronics Engineering. Lecture Notes in Electrical Engineering, vol 238. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-4981-2_67
Download citation
DOI: https://doi.org/10.1007/978-1-4614-4981-2_67
Published:
Publisher Name: Springer, New York, NY
Print ISBN: 978-1-4614-4980-5
Online ISBN: 978-1-4614-4981-2
eBook Packages: EngineeringEngineering (R0)