A New Detecting Technology of the Spontaneous Fire Position in Oil Tank

Conference paper
Part of the Lecture Notes in Electrical Engineering book series (LNEE, volume 163)

Abstract

As the amount of stored crude oil increased with the development of the petroleum industry, Self-ignition in the Oil tank has become one of the most serious safety problems that affect the sustainable development of national economy in China. In order to achieve a more efficient approach to detect accurately fire source position of spontaneous combustion oil tank so that the fire disaster can be prevented as early as possible, it is of importance to study the detection technique of the spontaneous fire position. A model of heat transfer was proposed. The simulation results of thermal modeling show the higher temperature of the fire source is, the faster changes of temperature curve are. The results show that detecting the spontaneous fire position by infrared technique is a feasible means and detection technology is introduced.

Keywords

Spontaneous combustion Detection of fire source Infrared technique Oil tank 

Notes

Acknowledgments

Supported by the National Natural Science Foundation of China (51104134); Program of General Administration of Quality Supervision, Inspection and Quarantine of China (2011QK390); XinMiao Project of Science & Technology Department of Zhejiang Province (2011R409003).

References

  1. 1.
    Lin HC, Yu JK (2000) Corrosion by active sulfur species petroleum refineries. Corros Sci Protect Technol (China) 12(6):341–345Google Scholar
  2. 2.
    Li P, Li JD, Zhao SL et al (2004) Research on the danger of fires in oil tanks with sulfur. Fire Safety J 40:331–338CrossRefGoogle Scholar
  3. 3.
    Zhang ZH, Chen SX (2003) The reason of fire and explosion accidents occurring in sulfur-containing petroleum tanks. Oil Gas Storage Transp (China) 22(10):31–33Google Scholar
  4. 4.
    Marques WH (2003) Physical, biological and chemical processes during storage and spontaneous combustion of waste fuel. Resour Conserv Recycl 40:53–69CrossRefGoogle Scholar
  5. 5.
    Rashi A, Singh D, Chauhan DS et al (2006) Detection of coal mine fires in the Jharia coal field using NOAA/AVHRR data. J Geophys Eng 3:212–218Google Scholar
  6. 6.
    Ann G Kim (2004) Locating fires in abandoned underground coal mines. Int J Coal Geol 59:49–62Google Scholar
  7. 7.
    Wang ZP, Cheng WM, Xin S et al (2003) The calculation of close-range coal inflammation position at coal-roads based on infrared detecting and inverse heat conduction technology. J China Coal Soc 28(6):603–607Google Scholar
  8. 8.
    Liu H, Wu C, Yang FQ et al (2011) Detection of spontaneous combustion of sulphide ores with infrared thermal imaging method. J Central South Univ (Sci Technol) 42(5):1425–1431Google Scholar
  9. 9.
    Liu H, Wu C, Shi Y (2011) Locating method of fire source for spontaneous combustion of sulfide ores. J Central South Univ Technol 18(4):1034–1040CrossRefGoogle Scholar
  10. 10.
    Ai LB (2010) Design of oil tank top insulation for energy saving. Oil Depot Gas Station 19(2):32–35Google Scholar