Abstract
Clinical densitometry is relatively new, but densitometry itself is actually quite old. It was first described over 100 years ago in the field of dental radiology as dentists attempted to quantify the bone density in the mandible [1, 2]. With today’s techniques, bone density can be quantified in almost every region of the skeleton. The extraordinary technical advances in recent years have expanded the realm of densitometry from that of a quantitative technique to that of an imaging technique as well. But even the oldest techniques remain both viable and valuable with computer modernization. Densitometry technologies have evolved as our understanding of relevant disease processes has increased. In a complimentary fashion, our understanding of the disease processes has increased as the technologies have evolved. Although current clinical guidelines have focused our attention overwhelmingly on DXA studies of the spine and proximal femur, other technologies for quantifying the bone density and other skeletal sites to which they may be applied are worthy of attention.
Notes
- 1.
Correlation indicates the strength of the association between 2 values or variables. The correlation value is denoted with the letter “r.” A perfect correlation would be indicated by an r value of +1.00 or −1.00.
- 2.
Techniques are compared on the basis of accuracy and precision, which can be described using the percent coefficient of variation (%CV). The %CV is the standard deviation divided by the average of replicate measurements expressed as a percentage. The lower the %CV, the better the accuracy or precision.
- 3.
Single-photon absorptiometry is discussed later in this chapter.
- 4.
Picture archiving and communications system
- 5.
Ward’s triangle was first described by F.O. Ward in Outlines of Human Osteology, London; Henry Renshaw, 1838. It is a triangular region created by the intersection of three groups of trabeculae in the femoral neck.
- 6.
- 7.
See Chap. 1 for a discussion of the composition of the radius and ulna.
- 8.
See Chap. 5 for a discussion of the effective dose.
- 9.
Global fracture risk refers to the risk of having any and all types of fractures combined. This is in contrast to a site-specific fracture risk prediction in which the risk for a fracture at a specific skeletal site is given, such as spine fracture risk or hip fracture risk.
- 10.
See Chap. 7 for a discussion of the calculation of the magnitude of change needed for 95 % confidence.
- 11.
Although spine bone density studies with dual-energy X-ray absorptiometry are often referred to as AP spine studies, the beam actually passes in a posterior to anterior direction. Such studies are correctly characterized as PA spine studies, but it is an accepted convention to refer to them as AP spine bone density studies.
References
Dennis J. A new system of measurement in X-ray work. Dental Cosmos. 1897;39:445–54.
Price WA. The science of dental radiology. Dental Cosmos. 1901;43:483–503.
Johnston CC, Epstein S. Clinical, biochemical, radiographic, epidemiologic, and economic features of osteoporosis. Orthop Clin North Am. 1981;12:559–69.
Aitken M. Measurement of bone mass and turnover. Osteoporosis in clinical practice. Bristol: John Wright & Sons Ltd; 1984. p. 19–20.
Singh J, Nagrath AR, Maini PS. Changes in trabecular pattern of the upper end of the femur as an index of osteoporosis. J Bone Joint Surg Am. 1970;52-A:457–67.
Bohr H, Schadt O. Bone mineral content of femoral bone and lumbar spine measured in women with fracture of the femoral neck by dual photon absorptiometry. Clin Orthop Relat Res. 1983;179:240–5.
Nordin BEC. Osteoporosis with particular reference to the menopause. In: Avioli LV, editor. The osteoporotic syndrome. New York: Grune & Stratton; 1983. p. 13–44.
Shimmins J, Anderson JB, Smith DA, et al. The accuracy and reproducibility of bone mineral measurements “in vivo”. (a) The measurement of metacarpal mineralisation using an X-ray generator. Clin Radiol. 1972;23:42–6.
Exton-Smith AN, Millard PH, Payne PR, Wheeler EF. Method for measuring quantity of bone. Lancet. 1969;2:1153–4.
Dequeker J. Precision of the radiogrammetric evaluation of bone mass at the metacarpal bones. In: Dequeker J, Johnston CC, editors. Non-invasive bone measurements: methodological problems. Oxford: IRL Press; 1982. p. 27–32.
Aitken JM, Smith CB, Horton PW, et al. The interrelationships between bone mineral at different skeletal sites in male and female cadavera. J Bone Joint Surg Br. 1974;56B:370–5.
Meema HE, Meindok H. Advantages of peripheral radiogrammetry over dual-photon absorptiometry of the spine in the assessment of prevalence of osteoporotic vertebral fractures in women. J Bone Miner Res. 1992;7:897–903.
Bywaters EGL. The measurement of bone opacity. Clin Sci. 1948;6:281–7.
Barnett E, Nordin BEC. Radiologic assessment of bone density. 1.-The clinical and radiological problem of thin bones. Br J Radiol. 1961;34:683–92.
Bouxsein ML, Palermo L, Yeung C, Black DM. Digital X-ray radiogrammetry predicts hip, wrist and vertebral fracture risk in elderly women: a prospective analysis from the Study of Osteoporotic Fractures. Osteoporos Int. 2002;12:358–65.
Cummings S, Black D, Nevitt M, et al. Appendicular bone density and age predict hip fractures in women. JAMA. 1990;263:665–8.
Mack PB, Brown WN, Trapp HD. The quantitative evaluation of bone density. Am J Roentgenol Radium Ther. 1949;61:808–25.
Vose GP, Mack PB. Roentgenologic assessment of femoral neck density as related to fracturing. Am J Roentgenol Radium Ther Nucl Med. 1963;89:1296–301.
Cummings SR, Black DM, Nevitt MC, et al. Bone density at various sites for prediction of hip fractures. Lancet. 1993;341:72–5.
Mazess RB. Noninvasive methods for quantitating trabecular bone. In: Avioli LV, editor. The osteoporotic syndrome. New York: Grune & Stratton; 1983. p. 85–114.
Mack PB, O’Brien AT, Smith JM, Bauman AW. A method for estimating degree of mineralization of bones from tracings of roentgenograms. Science. 1939;89:467.
Mack PB, Vogt FB. Roentgenographic bone density changes in astronauts during representative Apollo space flight. Am J Roentgenol Rad Ther Nucl Med. 1971;113:621–33.
Cosman F, Herrington B, Himmelstein S, Lindsay R. Radiographic absorptiometry: a simple method for determination of bone mass. Osteoporos Int. 1991;2:34–8.
Yates AJ, Ross PD, Lydick E, Epstein RS. Radiographic absorptiometry in the diagnosis of osteoporosis. Am J Med. 1995;98:41S–7S.
Yang S, Hagiwara S, Engelke K, et al. Radiographic absorptiometry for bone mineral measurement of the phalanges: precision and accuracy study. Radiology. 1994;192:857–9.
Kleerekoper M, Nelson DA, Flynn MJ, Pawluszka AS, Jacobsen G, Peterson EL. Comparison of radiographic absorptiometry with dual-energy X-ray absorptiometry and quantitative computed tomography in normal older white and black women. J Bone Miner Res. 1994;9:1745–9.
Mussolino ME, Looker AC, Madans JH, et al. Phalangeal bone density and hip fracture risk. Arch Intern Med. 1997;157:433–8.
Huang C, Ross PD, Yates AJ, et al. Prediction of fracture risk by radiographic absorptiometry and quantitative ultrasound: a prospective study. Calcif Tissue Int. 1998;6:380–4.
Cameron JR, Sorenson G. Measurements of bone mineral in vivo: an improved method. Science. 1963;142:230–2.
Vogel JM. Application principles and technical considerations in SPA. In: Genant HK, editor. Osteoporosis update 1987. San Francisco: University of California Printing Services; 1987. p. 219–31.
Johnston CC. Noninvasive methods for quantitating appendicular bone mass. In: Avioli L, editor. The osteoporotic syndrome. New York: Grune & Stratton; 1983. p. 73–84.
Barden HS, Mazess RB. Bone densitometry of the appendicular and axial skeleton. Top Geriatr Rehabil. 1989;4:1–12.
Kimmel PL. Radiologic methods to evaluate bone mineral content. Ann Intern Med. 1984;100:908–11.
Steiger P, Genant HK. The current implementation of single-photon absorptiometry in commercially available instruments. In: Genant HK, editor. Osteoporosis update 1987. San Francisco: University of California Printing Services; 1987. p. 233–40.
Chesnut CH. Noninvasive methods for bone mass measurement. In: Avioli L, editor. The Osteoporotic syndrome. 3rd ed. New York: Wiley-Liss; 1993. p. 77–87.
Gardsell P, Johnell O, Nilsson BE. The predictive value of bone loss for fragility fractures in women: a longitudinal study over 15 years. Calcif Tissue Int. 1991;49:90–4.
Hui SL, Slemenda CW, Johnston CC. Baseline measurement of bone mass predicts fracture in white women. Ann Intern Med. 1989;111:355–61.
Ross PD, Davis JW, Vogel JM, Wasnich RD. A critical review of bone mass and the risk of fractures in osteoporosis. Calcif Tissue Int. 1990;46:149–61.
Melton LJ, Atkinson EJ, O’Fallon WM, Wahner HW, Riggs BL. Long-term fracture prediction by bone mineral assessed at different skeletal sites. J Bone Miner Res. 1993;8:1227–33.
Black DM, Cummings SR, Genant HK, Nevitt MC, Palermo L, Browner W. Axial and appendicular bone density predict fracture in older women. J Bone Miner Res. 1992;7:633–8.
Nord RH. Technical considerations in DPA. In: Genant HK, editor. Osteoporosis update 1987. San Francisco: University of California Printing Services; 1987. p. 203–12.
Dunn WL, Wahner HW, Riggs BL. Measurement of bone mineral content in human vertebrae and hip by dual photon absorptiometry. Radiology. 1980;136:485–7.
Reed GW. The assessment of bone mineralization from the relative transmission of 241Am and 137Cs radiations. Phys Med Biol. 1966;11:174.
Roos B, Skoldborn H. Dual photon absorptiometry in lumbar vertebrae. I. Theory and method. Acta Radiol Ther Phys Biol. 1974;13:266–90.
Mazess RB, Ort M, Judy P. Absorptiometric bone mineral determination using 153Gd. In: Cameron JR, ed. Proceedings of bone measurements conference. U.S. Atomic Energy Commission, 1970:308–312.
Wilson CR, Madsen M. Dichromatic absorptiometry of vertebral bone mineral content. Invest Radiol. 1977;12:180–4.
Madsen M, Peppler W, Mazess RB. Vertebral and total body bone mineral content by dual photon absorptiometry. Calcif Tissue Res. 1976;2:361–4.
Wahner WH, Dunn WL, Mazess RB, et al. Dual-photon Gd-153 absorptiometry of bone. Radiology. 1985;156:203–6.
Lindsay R, Fey C, Haboubi A. Dual photon absorptiometric measurements of bone mineral density increase with source life. Calcif Tissue Int. 1987;41:293–4.
Cummings SR, Black DB. Should perimenopausal women be screened for osteoporosis? Ann Intern Med. 1986;104:817–23.
Drinka PJ, DeSmet AA, Bauwens SF, Rogot A. The effect of overlying calcification on lumbar bone densitometry. Calcif Tissue Int. 1992;50:507–10.
Curry TS, Dowdey JE, Murry RC. Christensen’s physics of diagnostic radiology. Philadelphia: Lea & Febiger; 1990. p. 1–522.
Rupich RC, Griffin MG, Pacifici R, Avioli LV, Susman N. Lateral dual-energy radiography: artifact error from rib and pelvic bone. J Bone Miner Res. 1992;7:97–101.
Louis O, Van Den Winkel P, Covens P, Schoutens A, Osteaux M. Dual-energy X-ray absorptiometry of lumbar vertebrae: relative contribution of body and posterior elements and accuracy in relation with neutron activation analysis. Bone. 1992;13:317–20.
Peel NFA, Johnson A, Barrington NA, Smith TWD, Eastell R. Impact of anomalous vertebral segmentation of measurements of bone mineral density. J Bone Miner Res. 1993;8:719–23.
Lees B, Stevenson JC. An evaluation of dual-energy X-ray absorptiometry and comparison with dual-photon absorptiometry. Osteoporos Int. 1992;2:146–52.
Kelly TL, Slovik DM, Schoenfeld DA, Neer RM. Quantitative digital radiography versus dual photon absorptiometry of the lumbar spine. J Clin Endocrinol Metab. 1988;76:839–44.
Holbrook TL, Barrett-Connor E, Klauber M, Sartoris D. A population-based comparison of quantitative dual-energy X-ray absorptiometry with dual-photon absorptiometry of the spine and hip. Calcif Tissue Int. 1991;49:305–7.
Pouilles JM, Tremollieres F, Todorovsky N, Ribot C. Precision and sensitivity of dual-energy X-ray absorptiometry in spinal osteoporosis. J Bone Miner Res. 1991;6:997–1002.
Laskey MA, Cirsp AJ, Cole TJ, Compston JE. Comparison of the effect of different reference data on Lunar DPX and Hologic QDR-1000 dual-energy X-ray absorptiometers. Br J Radiol. 1992;65:1124–9.
Pocock NA, Sambrook PN, Nguyen T, Kelly P, Freund J, Eisman J. Assessment of spinal and femoral bone density by dual X-ray absorptiometry: comparison of Lunar and Hologic instruments. J Bone Miner Res. 1992;7:1081–4.
Lai KC, Goodsitt MM, Murano R, Chesnut CC. A comparison of two dual-energy X-ray absorptiometry systems for spinal bone mineral measurement. Calcif Tissue Int. 1992;50:203–8.
Genant HK, Grampp S, Gluer CC, et al. Universal standardization for dual X-ray absorptiometry: patient and phantom cross-calibration results. J Bone Miner Res. 1994;9:1503–14.
Hanson J. Standardization of femur BMD. J Bone Miner Res. 1997;12:1316–7.
Kalender WA. Effective dose values in bone mineral measurements by photon-absorptiometry and computed tomography. Osteoporos Int. 1992;2:82–7.
Kelly TL, Crane G, Baran DT. Single x-ray absorptiometry of the forearm: precision, correlation, and reference data. Calcif Tissue Int. 1994;54:212–8.
Ruegsegger P, Elsasser U, Anliker M, Gnehn H, Kind H, Prader A. Quantification of bone mineralisation using computed tomography. Radiology. 1976;121:93–7.
Genant HK, Cann CE, Ettinger B, Gorday GS. Quantitative computed tomography of vertebral spongiosa: a sensitive method for detecting early bone loss after oophorectomy. Ann Intern Med. 1982;97:699–705.
Cann CE, Genant HK. Precise measurement of vertebral mineral content using computed tomography. J Comput Assist Tomogr. 1980;4:493–500.
Genant HK, Block JE, Steiger P, Gluer C. Quantitative computed tomography in the assessment of osteoporosis. In: Genant HK, editor. Osteoporosis update 1987. San Francisco: University of California Printing Services; 1987. p. 49–72.
Laval-Jeantet AM, Roger B, Bouysse S, Bergot C, Mazess RB. Influence of vertebral fat content on quantitative CT density. Radiology. 1986;159:463–6.
Reinbold W, Adler CP, Kalender WA, Lente R. Accuracy of vertebral mineral determination by dual-energy quantitative computed tomography. Skeletal Radiol. 1991;20:25–9.
Dunnill MS, Anderson JA, Whitehead R. Quantitative histological studies on age changes in bone. J Pathol Bacteriol. 1967;94:274–91.
Genant HK, Boyd D. Quantitative bone mineral analysis using dual energy computed tomography. Invest Radiol. 1977;12:545–51.
Cann CE. Quantitative computed tomography for bone mineral analysis: technical considerations. In: Genant HK, editor. Osteoporosis update 1987. San Francisco: University of California Printing Services; 1987. p. 131–44.
Gallagher C, Golgar D, Mahoney P, McGill J. Measurement of spine density in normal and osteoporotic subjects using computed tomography: relationship of spine density to fracture threshold and fracture index. J Comput Assist Tomogr. 1985;9:634–5.
Raymaker JA, Hoekstra O, Van Putten J, Kerkhoff H, Duursma SA. Osteoporosis fracture prevalence and bone mineral mass measured with CT and DPA. Skeletal Radiol. 1986;15:191–7.
Reinbold WD, Reiser UJ, Harris ST, Ettinger B, Genant HK. Measurement of bone mineral content in early postmenopausal and postmenopausal osteoporotic women. A comparison of methods. Radiology. 1986;160:469–78.
Sambrook PN, Bartlett C, Evans R, Hesp R, Katz D, Reeve J. Measurement of lumbar spine bone mineral: a comparison of dual photon absorptiometry and computed tomography. Br J Radiol. 1985;58:621–4.
Genant HK, Ettinger B, Harris ST, Block JE, Steiger P. Quantitative computed tomography in assessment of osteoporosis. In: Riggs BL, Melton LJ, editors. Osteoporosis: etiology, diagnosis and management. New York: Raven; 1988. p. 221–49.
Richardson ML, Genant HK, Cann CE, et al. Assessment of metabolic bone disease by quantitative computed tomography. Clin Orthop Relat Res. 1985;195:224–38.
Gluer C, Wu C, Jergas M, Goldstein S, Genant H. Three quantitative ultrasound parameters reflect bone structure. Calcif Tissue Int. 1994;55:46–52.
Nicholson P, Haddaway M, Davie M. The dependence of ultrasonic properties on orientation in human vertebral bone. Phys Med Biol. 1994;39:1013–24.
Njeh CF, Boivin CM, Langton CM. The role of ultrasound in the assessment of osteoporosis: a review. Osteoporos Int. 1997;7:7–22.
Hans D, Dargent-Molina P, Schott AM, et al. Ultrasonographic heel measurements to predict hip fracture in elderly women: the EPIDOS prospective study. Lancet. 1996;348:511–4.
Bauer DC, Gluer CC, Cauley JA, et al. Bone ultrasound predicts fractures strongly and independently of densitometry in older women: a prospective study. Arch Intern Med. 1997;157:629–34.
Njeh CF, Hans D, Li J, et al. Comparison of six calcaneal quantitative ultrasound devices: precision and hip fracture discrimination. Osteoporos Int. 2000;11:1051–62.
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer Science+Business Media New York
About this chapter
Cite this chapter
Bonnick, S.L., Lewis, L.A. (2013). Densitometry Techniques. In: Bone Densitometry for Technologists. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-3625-6_2
Download citation
DOI: https://doi.org/10.1007/978-1-4614-3625-6_2
Published:
Publisher Name: Springer, New York, NY
Print ISBN: 978-1-4614-3624-9
Online ISBN: 978-1-4614-3625-6
eBook Packages: MedicineMedicine (R0)