Advertisement

Liquid Hydrogen Pumping for Hydrogen Targets

  • J. W. Mark
Part of the Advances in Cryogenic Engineering book series (ACRE, volume 19)

Abstract

Forced circulation of liquid hydrogen through hydrogen targets is necessary when the geometry and heat load exceed the capacity of normal convection systems. Three small pumps, one centrifugal and two positive displacement, were built for that purpose. Hydrogen flows of one-half to two liters/min were attained while the pressure head developed was 10 to 40 ft of liquid hydrogen.

Keywords

Centrifugal Pump Liquid Hydrogen Piston Pump Positive Displacement Hydrogen Target 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    F. Bulos, A. Odian, F. Villa, and D. Yont, “Streamer Chamber Development,” SLAC Rept. 74 (June 1967).CrossRefGoogle Scholar
  2. 2.
    J. Mark and W. Pierce, “Hydrogen Targets at SLAC,” SLAC-PUB-833 (March 1971).Google Scholar