Abstract

Representative stack samples were taken from typical combustion sources and wood burning stoves using isokinetic sampling techniques. Each segment of the sampling trains and coincident collected flyash samples were analyzed for polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs). Analyses indicated that the bulk of the PCDDs/PCDFs were directly associated with particulate matter in the exhausted effluent and that woodstove effluents contained only components with high chlorine numbers. Samples were submitted to cytosol receptor bioassay and produced responses far higher than the expected values based on the 2,3,7,8-tetrachloro-dibenzo-p-dioxin (TCDD) concentrations measured. Results from solvent extraction and cleanup column recovery studies are reported. Data for PCDDs/PCDFs concentrations are reported and discussed.

Keywords

Electrostatic Precipitator Wood Burning Combustion Source Sampling Train Secondary Combustion 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Air Pollution Control Diretorate, Environment Canada, Standard Reference Methods for Source Testing: Measurement of Emissions of Particulates from Stationary Sources, EPS l-AP-74-1, Feb. 1974.Google Scholar
  2. Air Pollution Control Directorate, Environment Canada, Collection of Organic Particulate Samples from a Municipal Incinerator and a Coal-Fired Boiler, Internal Report, File No. 4172-2, Dec., 1980.Google Scholar
  3. Buser, H.R., and Rappe, C. Anal. Chem., 52 (14): 2257–2262, 1980.CrossRefGoogle Scholar
  4. Cavallaro, A., Bandi, G., Invernizzi, G., Luciani, L., Mongini, E., and Gorni, A. Chemosphere, 9: 611–621, 1980.CrossRefGoogle Scholar
  5. Eiceman, G.A., Clement, R.E., and Karasek, F.W. Anal. Chem., 15 (14) 2343–2350, 1979.CrossRefGoogle Scholar
  6. Eiceman, G.A., Clement, R.E., and Karasek, F.W. Anal. Chem., 53 (7): 955–959, 1981.CrossRefGoogle Scholar
  7. Kooke, R.M.M., Lustenhouwer, J.W.A., Olie, K., and Hutzinger, O. Anal. Chem., 53 (3):641–463, 1981.CrossRefGoogle Scholar
  8. Lamparski, L.L., and Nestrick, T.J. Anal. Chem., 52 (13):2045–2054, 1980.CrossRefGoogle Scholar
  9. Liberti, A., Brocco, D., Cecinato, A., and Passanzini, M. Mikrochimica Acta., 271–280, 1981.Google Scholar
  10. Nestrick, T.J., Lamparski, L.L. and Stehl, R.H. Anal. Chem., 51 (13) 2273–2278, 1979.CrossRefGoogle Scholar
  11. Reese, G.A.V., Smillie, D., Tosine, H. and Osborne, J. Abstract, 28th Canadian Spectroscopy Symposium, Ottawa, September 28–30, 1981.Google Scholar
  12. Safe, S., Bandiera, S., Hutzinger, O., Olie, K., Lustenhouwer, J.W.A. and Okey, A.B. Chemosphere, 10: 19–25, 1981.CrossRefGoogle Scholar
  13. The Dow Chemical Co., Midland, Michigan. Stack Gas Sampling Proce¬dure for the Determination of Chlorinated Dioxin Emissions from Stationary Source, ML-AM 78-64, Nov., 1978.Google Scholar

Copyright information

© Plenum Press, New York 1983

Authors and Affiliations

  • D. K. W. Wang
    • 1
  • D. H. Chiu
    • 1
  • P. K. Leung
    • 1
  • R. S. Thomas
    • 1
  • R. C. Lao
    • 1
  1. 1.Air Pollution Control DirectorateEnvironment CanadaOttawaCanada

Personalised recommendations