Abstract

Measurement of blood oxygen and carbon dioxide tensions is routinely employed to assist clinicians in patient evaluation and treatment. This method necessitates either arterial or venous puncture or indwelling hollow catheter to obtain the sample. Ex vivo Clark Polarographic O2 and the Severinghaus CO2 electrodes are the actual measuring devices. Many attempts have been made at continuous analysis using the O2 and CO2 electrodes with specially designed flow through cuvettes or miniature catheter tip electrodes. Most of these methods suffer from lack of repeatability and/or loss or linearity.

Keywords

Membrane Material Steel Spring Quantitative Response Cerebral Blood Flow Change Catheter Tubing 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1).
    L.B. Strang, J. Appl. Physiol., 1961, 16, 562.Google Scholar
  2. 2).
    S. Woldring, G. Owens and D. Woolford, Science, 1966, 153, 885.CrossRefGoogle Scholar
  3. 3).
    A. Wald, W.K. Hass and J. Ranschoff, JAAMI, 1971, 5 325.Google Scholar
  4. 4).
    M. Roberts, E.T. Colton, G. Owens, D.D. Thomas and G.M. Watkins, Med. and Biol. Eng., 1975, 13, 535.Google Scholar
  5. 5).
    M.L. Dyken, Stroke, 1972, 3 279.CrossRefGoogle Scholar
  6. 6).
    S. Woldring, JAAMI, 1970, 4, no. 2.Google Scholar
  7. 7).
    A. Key, Med. and Biol. Eng., 1975, 13, 583.CrossRefGoogle Scholar
  8. 8).
    A. Wald, W.K. Hass, F.P. Siew and D.H. Wood, Med. and Biol. Eng., 1970, 8, 111.CrossRefGoogle Scholar
  9. 9).
    “Encyclopedia of Polymer Science -and Technology: Plastics, Resins, Rubbers, Fibers”, Vol. 13, pp. 560–576, pp. 630-290, Vol. 2, p. 324, Wiley, New York, 1965 and 1970.Google Scholar
  10. 10).
    G.A. Grode, S.J. Anderson and R.D. Falb, Trans. Am. Soc. Artificial Internal Organs, 1969, 15, 1.Google Scholar
  11. 11).
    J.W. Brantigan, V.L. Gott, M.L. Vestal, G.J. Fergusson and W.H. Johnston, J. Appl. Physiol., 1970, 28, 375.Google Scholar

Copyright information

© Plenum Press, New York 1979

Authors and Affiliations

  • T. D. Johnson
    • 1
  • G. M. Watkins
    • 1
  • J. Holsinger
    • 1
  • M. P. Roberts
    • 1
  • D. D. Thomas
    • 1
  1. 1.Veterans Administration HospitalUniversity of South FloridaTampaUSA

Personalised recommendations