Abstract
This chapter focuses on a few techniques that a practitioner should know when he uses biofeedback equipment. Since biofeedback is a psychophysiological mirror, it is useful only if the equipment records and amplifies the biological signal accurately. The techniques discussed will apply to electromyographic (EMG), thermal, electrodermal (EDR or GSR), or skin potential response (SPR), and electroencephalic (EEG) biofeedback equipment. Obviously these concepts can be extended to other feedback devices not discussed here. The recorded measures must be accurate so that the practitioner can interpret changes in the feedback signal as indications of changes in the psychophysiology or autonomic self-regulation of the trainee (Peper, 1974). (The term trainee is used instead of patient or client as I perceive biofeedback training as a learning tool.) For example, the EMG of the forearm extensor could be as high as 18 μV even though there is no voluntary muscle tension. The reading may imply that the person had tensed his forearm extensors through lifting the fingers or bending the hand back at the wrist, and that the reading is not due to artifacts such as 60-Hz or sensor (electrode) lead movements. To avoid misinterpretation of the recorded physiological data, the practitioner should be familiar with the human interface of the equipment: (1) knowledge of the equipment, i.e.. the flow diagram, which is a schematic representation of how the signal is processed; (2) external, internal, and physiological factors affecting the biological functions recorded; and (3) suggested behavioral testing procedures to assess whether the biofeedback equipment is working.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Basmajian, JV, Facts vs. myths in EMG biofeedback. Biofeedback and Self-Regulation, 1976. 1(4). 369 371.
Brown, C, Methods in pathophysiology. Baltimore Williams & Wilkins, 1967.
Cromwell, L, Weibell. G J., Pfeiffer. E. A. & Usselman, L B. Biomedical instrumentation and measurements. Englewood Cliffs. New Jersey: Prentice-Hall. 1973.
Geddes, L A, & Baker. L. F. Principles of applied biomedical instrumentation. New York: Wiley. 1975.
Greenfield, N. S., & Sternbach, R, Handbook of psychophysiology. New York: Holt. Rinehart & Winston, 1972.
Mulholland, T B, & Peper, E Occipital alpha and accommodative vergence. pursuit tracking and fast eye movements. Psychophysiology, 1971. 8 (5). 556–575.
Peper, L, Problems in heart rate and alpha electrocncephalographic feedback. Kybernetik. 1974. 14. 217–221.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1979 Plenum Press, New York
About this chapter
Cite this chapter
Peper, E. (1979). A Beginner’s Behavioral Test Guide to Biofeedback Instrumentation. In: Peper, E., Ancoli, S., Quinn, M. (eds) Mind/Body Integration. Springer, Boston, MA. https://doi.org/10.1007/978-1-4613-2898-8_17
Download citation
DOI: https://doi.org/10.1007/978-1-4613-2898-8_17
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4613-2900-8
Online ISBN: 978-1-4613-2898-8
eBook Packages: Springer Book Archive